This object is used to enable or disable the recording of
usage counts (e.g., cell or frame counts) for an ATM PVC.
disabled = No usage counts are generated for this circuit
egress = Egress usage counts are generated, where egress
refers to data sent to the user (on a UNI) or to
the network (on a network interface).
ingress = Ingress usage counts are generated, where ingress
refers to data received from the user (on a UNI)
or from the network (on a network interface).
enabled = Both ingress and egress counts are generated
Note: usage records are not generated if PVC Recording
(atmacctCktControl) is disabled.
This object is defined at the user (UNI) and network
interfaces (B-ICI and NNI).
The default value of this object is disabled(1) at the UNI
and disabled(1) at the network interface.
Note: this object is read-only after initial provisioning
of the circuit.
Parsed from file cascade.mib.txt
Company: cascade
Module: CASCADE-MIB
Vendor: Cascade Communications
Module: CASCADE-MIB (cascade.mib)
Type: TABULAR
Access: read-write
Syntax: INTEGER
Automatically extracted from www.mibdepot.com
atmacctCktUsageMeasurement OBJECT-TYPE SYNTAX INTEGER { disabled (1), egress (2), ingress (3), enabled (4) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to enable or disable the recording of usage counts (e.g., cell or frame counts) for an ATM PVC. disabled = No usage counts are generated for this circuit egress = Egress usage counts are generated, where egress refers to data sent to the user (on a UNI) or to the network (on a network interface). ingress = Ingress usage counts are generated, where ingress refers to data received from the user (on a UNI) or from the network (on a network interface). enabled = Both ingress and egress counts are generated Note: usage records are not generated if PVC Recording (atmacctCktControl) is disabled. This object is defined at the user (UNI) and network interfaces (B-ICI and NNI). The default value of this object is disabled(1) at the UNI and disabled(1) at the network interface. Note: this object is read-only after initial provisioning of the circuit." ::= { atmacctCktEntry 4 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.277.16.1.25.1.1 | atmacctCktSrcIfIndex | 0 | 0 | Index: source logical-port identifier. |
1.3.6.1.4.1.277.16.1.25.1.2 | atmacctCktSrcDlci | 0 | 0 | Index: source DLCI (concatenated VPI:VCI). |
1.3.6.1.4.1.277.16.1.25.1.3 | atmacctCktControl | 0 | 0 | This object is used to enable or disable ATM PVC recording for accounting purposes. disabled = The PVC will not be recorded at th… |
1.3.6.1.4.1.277.16.1.25.1.5 | atmacctCktChargeablePartyId | 0 | 0 | This object defines a 1 to 16 digit decimal chargeable party for this ATM PVC, per Bellcore GR-1110-CORE. Note: this object is r… |
1.3.6.1.4.1.277.16.1.25.1.6 | atmacctCktSendNew | 0 | 0 | This object provides an interface for the Accounting Server to request the NEW usage data record for the corresponding circuit. … |
1.3.6.1.4.1.277.16.1.25.1.7 | atmacctCktCreationTime | 0 | 0 | This object represents the time (UCT, seconds since Jan. 1, 1970) that the circuit was created. Once created, this object is rea… |