The reason the system started. Possible values are:
reset The 'reset' button on the
switch font panel was
pressed.
default The 'default' button on the
switch front panel was
pressed.
resetDefault The 'reset' and 'default'
buttons on the switch front
panel were pressed.
watchdog The software watchdog timed
out.
fatal A fatal error was
encountered in the software.
controlled Management requested
restart.
coldStart Power up.
unknown Unknown reason.
featureModuleRemoved The feature module was
removed while the switch was
operating.
Parsed from file oc9100.mib.txt
Company: None
Module: Olicom-crossfireAtmSwitch-MIB
The reason the system started. Possible values are:
reset The 'reset' button on the
switch font panel was
pressed.
default The 'default' button on the
switch front panel was
pressed.
resetDefault The 'reset' and 'default'
buttons on the switch front
panel were pressed.
watchdog The software watchdog timed
out.
fatal A fatal error was
encountered in the software.
controlled Management requested
restart.
coldStart Power up.
unknown Unknown reason.
featureModuleRemoved The feature module was
removed while the switch was
operating.
Parsed from file Olicom-crossfireAtmSwitch-MIB.mib
Module: Olicom-crossfireAtmSwitch-MIB
Vendor: Olicom A/S
Module: Olicom-crossfireAtmSwitch-MIB
[Automatically extracted from oidview.com]
termRestartInfoRestartReason OBJECT-TYPE SYNTAX INTEGER { reset(1), default(2), resetDefault(3), watchdog(4), fatal(5), controlled(6), coldStart(7), unknown(8), featureModuleRemoved(9) } ACCESS read-only STATUS mandatory DESCRIPTION "The reason the system started. Possible values are: reset The 'reset' button on the switch font panel was pressed. default The 'default' button on the switch front panel was pressed. resetDefault The 'reset' and 'default' buttons on the switch front panel were pressed. watchdog The software watchdog timed out. fatal A fatal error was encountered in the software. controlled Management requested restart. coldStart Power up. unknown Unknown reason. featureModuleRemoved The feature module was removed while the switch was operating." ::= { termRestartInfo 14 }
termRestartInfoRestartReason OBJECT-TYPE SYNTAX INTEGER { reset(1), default(2), resetDefault(3), watchdog(4), fatal(5), controlled(6), coldStart(7), unknown(8), featureModuleRemoved(9) } ACCESS read-only STATUS mandatory DESCRIPTION "The reason the system started. Possible values are: reset The 'reset' button on the switch font panel was pressed. default The 'default' button on the switch front panel was pressed. resetDefault The 'reset' and 'default' buttons on the switch front panel were pressed. watchdog The software watchdog timed out. fatal A fatal error was encountered in the software. controlled Management requested restart. coldStart Power up. unknown Unknown reason. featureModuleRemoved The feature module was removed while the switch was operating." ::= { termRestartInfo 14 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.285.2.6.1.5.14.0 | termRestartInfoRestartReason | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.285.2.6.1.5.1 | termRestartInfoRestartTime | 1 | 1 | Time when the system was restarted (measured in seconds since 00:00:00 UTC on 1 January 1970). |
1.3.6.1.4.1.285.2.6.1.5.2 | termRestartInfoSwSection1StatusWord | 1 | 1 | The value of the status word in the first section of the software image flash memory. |
1.3.6.1.4.1.285.2.6.1.5.3 | termRestartInfoSwSection2StatusWord | 1 | 1 | The value of the status word in the second section of the software image flash memory. |
1.3.6.1.4.1.285.2.6.1.5.4 | termRestartInfoSwImageLoaded | 1 | 1 | The number of the software image currently running. |
1.3.6.1.4.1.285.2.6.1.5.5 | termRestartInfoFutureTestMode | 1 | 1 | Indicates if the software is running in 'Future Test' mode, i.e. if this is a one-shot test of a software image. |
1.3.6.1.4.1.285.2.6.1.5.6 | termRestartInfoBootpExecuted | 1 | 1 | Indicates if BOOTP was executed to load the software image. |
1.3.6.1.4.1.285.2.6.1.5.7 | termRestartInfoReloadTime | 1 | 1 | Time when the software was stored in the switch (measured in seconds since 00:00:00 UTC on 1 January 1970). |
1.3.6.1.4.1.285.2.6.1.5.8 | termRestartInfoBootpReason | 1 | 1 | The reason that BOOTP was executed to load the software. The possible values are: noSw There was no executable softwa… |
1.3.6.1.4.1.285.2.6.1.5.9 | termRestartInfoServerIpAddress | 1 | 1 | The IP address of the server that provided the software image during the BOOTP operation. |
1.3.6.1.4.1.285.2.6.1.5.10 | termRestartInfoServerMacAddress | 1 | 1 | The MAC address of the of the server that provided the software image during the BOOTP operation. |
1.3.6.1.4.1.285.2.6.1.5.11 | termRestartInfoFileName | 1 | 1 | The name of the software image file on the BOOTP server. |
1.3.6.1.4.1.285.2.6.1.5.12 | termRestartInfoBbsramTerminationTimestamp | 1 | 1 | Time when the system last closed down (measured in seconds since 00:00:00 UTC on 1 January 1970). |
1.3.6.1.4.1.285.2.6.1.5.13 | termRestartInfoTerminationReason | 1 | 1 | The reason the system last closed down. Possible values are: unknown Unknown reason. controlled Managem… |
1.3.6.1.4.1.285.2.6.1.5.15 | termRestartInfoHwReconfigState | 1 | 1 | The reconfiguration state of the switch. Possible values are: totalReconfig The stored configuration is invalidated because of… |
1.3.6.1.4.1.285.2.6.1.5.16 | termRestartInfoBbsram | 1 | 1 | Data stored in battery backed-up RAM when the switch terminated. |