The reason that BOOTP was executed to load the
software. The possible values are:
noSw There was no executable software
image in the switch.
chksumError The software image in the switch
had a check sum error.
invalidSwStatus The status word associated with
the software image in the switch
was invalid.
pushButtons The 'default' and 'reset' buttons
on the switch font panel were
pressed.
undefined Other reasons.
Parsed from file oc9100.mib.txt
Company: None
Module: Olicom-crossfireAtmSwitch-MIB
The reason that BOOTP was executed to load the
software. The possible values are:
noSw There was no executable software
image in the switch.
chksumError The software image in the switch
had a check sum error.
invalidSwStatus The status word associated with
the software image in the switch
was invalid.
pushButtons The 'default' and 'reset' buttons
on the switch font panel were
pressed.
undefined Other reasons.
Parsed from file Olicom-crossfireAtmSwitch-MIB.mib
Module: Olicom-crossfireAtmSwitch-MIB
Vendor: Olicom A/S
Module: Olicom-crossfireAtmSwitch-MIB
[Automatically extracted from oidview.com]
termRestartInfoBootpReason OBJECT-TYPE SYNTAX INTEGER { noSw(1), chksumError(2), invalidSwStatus(3), pushButtons(4), undefined(5) } ACCESS read-only STATUS mandatory DESCRIPTION "The reason that BOOTP was executed to load the software. The possible values are: noSw There was no executable software image in the switch. chksumError The software image in the switch had a check sum error. invalidSwStatus The status word associated with the software image in the switch was invalid. pushButtons The 'default' and 'reset' buttons on the switch font panel were pressed. undefined Other reasons." ::= { termRestartInfo 8 }
termRestartInfoBootpReason OBJECT-TYPE SYNTAX INTEGER { noSw(1), chksumError(2), invalidSwStatus(3), pushButtons(4), undefined(5) } ACCESS read-only STATUS mandatory DESCRIPTION "The reason that BOOTP was executed to load the software. The possible values are: noSw There was no executable software image in the switch. chksumError The software image in the switch had a check sum error. invalidSwStatus The status word associated with the software image in the switch was invalid. pushButtons The 'default' and 'reset' buttons on the switch font panel were pressed. undefined Other reasons." ::= { termRestartInfo 8 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.285.2.6.1.5.8.0 | termRestartInfoBootpReason | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.285.2.6.1.5.1 | termRestartInfoRestartTime | 1 | 1 | Time when the system was restarted (measured in seconds since 00:00:00 UTC on 1 January 1970). |
1.3.6.1.4.1.285.2.6.1.5.2 | termRestartInfoSwSection1StatusWord | 1 | 1 | The value of the status word in the first section of the software image flash memory. |
1.3.6.1.4.1.285.2.6.1.5.3 | termRestartInfoSwSection2StatusWord | 1 | 1 | The value of the status word in the second section of the software image flash memory. |
1.3.6.1.4.1.285.2.6.1.5.4 | termRestartInfoSwImageLoaded | 1 | 1 | The number of the software image currently running. |
1.3.6.1.4.1.285.2.6.1.5.5 | termRestartInfoFutureTestMode | 1 | 1 | Indicates if the software is running in 'Future Test' mode, i.e. if this is a one-shot test of a software image. |
1.3.6.1.4.1.285.2.6.1.5.6 | termRestartInfoBootpExecuted | 1 | 1 | Indicates if BOOTP was executed to load the software image. |
1.3.6.1.4.1.285.2.6.1.5.7 | termRestartInfoReloadTime | 1 | 1 | Time when the software was stored in the switch (measured in seconds since 00:00:00 UTC on 1 January 1970). |
1.3.6.1.4.1.285.2.6.1.5.9 | termRestartInfoServerIpAddress | 1 | 1 | The IP address of the server that provided the software image during the BOOTP operation. |
1.3.6.1.4.1.285.2.6.1.5.10 | termRestartInfoServerMacAddress | 1 | 1 | The MAC address of the of the server that provided the software image during the BOOTP operation. |
1.3.6.1.4.1.285.2.6.1.5.11 | termRestartInfoFileName | 1 | 1 | The name of the software image file on the BOOTP server. |
1.3.6.1.4.1.285.2.6.1.5.12 | termRestartInfoBbsramTerminationTimestamp | 1 | 1 | Time when the system last closed down (measured in seconds since 00:00:00 UTC on 1 January 1970). |
1.3.6.1.4.1.285.2.6.1.5.13 | termRestartInfoTerminationReason | 1 | 1 | The reason the system last closed down. Possible values are: unknown Unknown reason. controlled Managem… |
1.3.6.1.4.1.285.2.6.1.5.14 | termRestartInfoRestartReason | 1 | 1 | The reason the system started. Possible values are: reset The 'reset' button on the switch font panel was pressed… |
1.3.6.1.4.1.285.2.6.1.5.15 | termRestartInfoHwReconfigState | 1 | 1 | The reconfiguration state of the switch. Possible values are: totalReconfig The stored configuration is invalidated because of… |
1.3.6.1.4.1.285.2.6.1.5.16 | termRestartInfoBbsram | 1 | 1 | Data stored in battery backed-up RAM when the switch terminated. |