If enabled, the relay will respond to system events by opening and closing.
If disabled, then it will be left in the default state of 'Clear',
where clear is relative to the 'sense' assigned to the relay. The default
sense is Normal, which means a closed relay is considered in the alarm state.
Parsed from file sonusAm.mib.txt
Company: None
Module: SONUS-ALARM-CONTACT-MIB
If enabled, the relay will respond to system events by opening and closing.
If disabled, then it will be left in the default state of 'Clear',
where clear is relative to the 'sense' assigned to the relay. The default
sense is Normal, which means a closed relay is considered in the alarm state.
Parsed from file SONUS-ALARM-CONTACT-MIB.mib
Module: SONUS-ALARM-CONTACT-MIB
Vendor: Sonus Networks, Inc.
Module: SONUS-ALARM-CONTACT-MIB
[Automatically extracted from oidview.com]
sonusAlarmOutAdmnOperState OBJECT-TYPE SYNTAX SonusAdminState MAX-ACCESS read-write STATUS current DESCRIPTION " If enabled, the relay will respond to system events by opening and closing. If disabled, then it will be left in the default state of 'Clear', where clear is relative to the 'sense' assigned to the relay. The default sense is Normal, which means a closed relay is considered in the alarm state." DEFVAL { enabled } ::= { sonusAlarmOutAdmnEntry 3 }
sonusAlarmOutAdmnOperState OBJECT-TYPE SYNTAX SonusAdminState MAX-ACCESS read-write STATUS current DESCRIPTION " If enabled, the relay will respond to system events by opening and closing. If disabled, then it will be left in the default state of 'Clear', where clear is relative to the 'sense' assigned to the relay. The default sense is Normal, which means a closed relay is considered in the alarm state." DEFVAL { enabled } ::= { sonusAlarmOutAdmnEntry 3 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2879.2.1.6.1.1.1.1 | sonusAlarmOutAdmnShelfIndex | 0 | 0 | Identifies the target shelf within the node. |
1.3.6.1.4.1.2879.2.1.6.1.1.1.2 | sonusAlarmOutAdmnRelayIndex | 0 | 0 | Identifies the target outbound relay within the shelf. |
1.3.6.1.4.1.2879.2.1.6.1.1.1.4 | sonusAlarmOutAdmnValue | 0 | 0 | Default value for the relays, either ALARM or CLEAR. Alarm contact five can be manually reconfigured. Alarm Contacts 1 thru 4 ha… |
1.3.6.1.4.1.2879.2.1.6.1.1.1.5 | sonusAlarmOutAdmnSense | 0 | 0 | Select NORMAL if a CLOSED relay indicates an alarm condition. Select INVERTED if an OPEN relay indicates an alarm condition. |
1.3.6.1.4.1.2879.2.1.6.1.1.1.6 | sonusAlarmOutAdmnStartDelay | 0 | 0 | Start Delay will hold the outbound relays in reset for the time period(seconds) specified. This is intended to mitigate nuisance… |
1.3.6.1.4.1.2879.2.1.6.1.1.1.7 | sonusAlarmOutAdmnCutoff | 0 | 0 | Cutoff will cause the outbound relay selected to be set to its alarm clear state, relative to the relay 'sense' setting. This all… |