The Timer T39 is started when MCID request is sent. It is only relevent in the ITU.
Parsed from file sonusSs7Fe.mib.txt
Company: None
Module: SONUS-SS7-SERVICES-MIB
The Timer T39 is started when MCID request is sent. It is only relevent in the ITU.
Parsed from file SONUS-SS7-SERVICES-MIB.mib
Module: SONUS-SS7-SERVICES-MIB
Vendor: Sonus Networks, Inc.
Module: SONUS-SS7-SERVICES-MIB
[Automatically extracted from oidview.com]
sonusSs7NodeTimerT39 OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T39 is started when MCID request is sent. It is only relevent in the ITU." ::= { sonusSs7NodeEntry 59 }
sonusSs7NodeTimerT39 OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timer T39 is started when MCID request is sent. It is only relevent in the ITU." ::= { sonusSs7NodeEntry 59 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.1 | sonusSs7NodeIndex | 0 | 0 | Identifies the target SS7 Node entry. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.2 | sonusSs7NodeState | 0 | 0 | The administrative state of this SS7 Node entry. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.3 | sonusSs7NodeName | 0 | 0 | The name of this SS7 Node instance. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.4 | sonusSs7NodePointCode | 0 | 0 | The SS7 point code assigned to this SS7 Node entry. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.5 | sonusSs7NodeServices | 0 | 0 | The type of SS7 services (ISUP, TCAP, or both) supported by this SS7 Node entry. As of GSX release 3.02.00, isupOnly is now the … |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.6 | sonusSs7NodeProtocol | 0 | 0 | The SS7 protocol type supported by this SS7 Node entry. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.7 | sonusSs7NodeTcapSsn | 0 | 0 | If Tcap is supported by this SS7 Node, specifies the Sub System Number for this node entry. This object is obsoleted as of GSX re… |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.8 | sonusSs7NodeIsupStatus | 0 | 0 | This status value has been replaced by sonusSs7NodeStatIsup |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.9 | sonusSs7NodeTcapStatus | 0 | 0 | Specifies the operating status of the TCAP service within this SS7 Node. This object is obsoleted as of GSX release 3.02.00. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.10 | sonusSs7NodeMtpStatus | 0 | 0 | This status value has been replaced by sonusSs7NodeStatMtp |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.11 | sonusSs7NodeGatewayAssignment | 0 | 0 | The name of the SS7 Gateway to which this SS7 Node is assigned. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.12 | sonusSs7NodeNativePointCode | 0 | 0 | The native point code of the SS7 node. e.g. For ITU the point code is in 3 bit 8 bit 3 bit format adding up to 14 bits whereas AN… |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.13 | sonusSs7NodeMode | 0 | 0 | Specifies the service mode for this SS7 Node. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.14 | sonusSs7NodeConnCntrl | 0 | 0 | Specifies when the Node will establish an ISUP connection with the SS7 Gateway. This parameter is used to minimize unnecessary c… |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.15 | sonusSs7NodeRowStatus | 0 | 0 | None |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.16 | sonusSs7NodeStdPointCode | 0 | 0 | Octet string of the point code. This gives the actual representation the user entered. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.17 | sonusSs7NodePointCodeSize | 0 | 0 | Indicates the total number of bits in the point code. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.18 | sonusSs7NodePointCodeFormatType | 0 | 0 | The Point Code format type being defined. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.19 | sonusSs7NodeServerProtocol | 0 | 0 | The interface used between the SS7 gateway and the SS7 client on the GSX9000 |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.20 | sonusSs7NodeHandShakeInterval | 0 | 0 | HandShake interval between the client and the server in seconds. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.21 | sonusSs7NodeTimerT1 | 0 | 0 | The Timer T1 could be changed from its default using this entry. The valid ranges are 4 - 15 seconds for ANSI and 15 - 60 Second… |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.22 | sonusSs7NodeTimerT2 | 0 | 0 | The Timer T2 could be changed from its default using this entry. The valid value for ITU is 3 Minutes. This timer has no releven… |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.23 | sonusSs7NodeTimerT3 | 0 | 0 | The T3 timer is started on receipt of an Overload message in the ITU network. This has no relevence in the ANSI network. The val… |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.24 | sonusSs7NodeTimerT4 | 0 | 0 | The Timer T4 could be changed from its default using this entry. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.25 | sonusSs7NodeTimerT5 | 0 | 0 | The T5 Timer is started when the release message is sent. The valid values as per the specifications are 60 seconds for the ANSI… |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.26 | sonusSs7NodeTimerT6 | 0 | 0 | The timer T6 is started when the suspend message is received. The valid range for this timer is 1 to 120 seconds. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.27 | sonusSs7NodeTimerT7 | 0 | 0 | The Timer T7 could be changed from its default using this entry. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.28 | sonusSs7NodeTimerT8 | 0 | 0 | The T8 timer is timer to be started with continuity check has been indicated in the IAM. The valid range is 10 to 15 seconds. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.29 | sonusSs7NodeTimerT9 | 0 | 0 | The Timer T9 started when outgoing international exchange recieves an ACM. The valid range is 120 to 240 seconds. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.30 | sonusSs7NodeTimerT10 | 0 | 0 | The Timer T10 is started when the last digit is recived in interworking situations. This timer has no relevence to ANSI. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.31 | sonusSs7NodeTimerT11 | 0 | 0 | The Timer T11 is started when the latest address message is received in interworking situations. The valid range is 15 to 20 sec… |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.32 | sonusSs7NodeTimerT12 | 0 | 0 | The Timer T12 is started when a blocking message is sent. The valid ranges are 4 to 15 seconds for ANSI and 15 to 60 seconds for… |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.33 | sonusSs7NodeTimerT13 | 0 | 0 | The Timer T13 is started when the initial blocking messge is sent. The valid value for ANSI is 60 seconds and for ITU is between… |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.34 | sonusSs7NodeTimerT14 | 0 | 0 | The Timer T14 is started when an unblocking message is sent. The valid values are 4 to 15 seconds for ANSI and 15 to 60 seconds … |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.35 | sonusSs7NodeTimerT15 | 0 | 0 | The Timer T15 is started when the initial unblocking message is sent. The valid values are 60 seconds for ANSI and 300 to 900 se… |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.36 | sonusSs7NodeTimerT16 | 0 | 0 | The Timer T16 is started when the reset circuit is started which was not due to expiry of T5. The valid ranges are 4 to 15 secon… |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.37 | sonusSs7NodeTimerT17 | 0 | 0 | The Timer T17 is started when initial reset message is sent. The valid values are 60 seconds for ANSI and 300 to 900 for ITU. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.38 | sonusSs7NodeTimerT18 | 0 | 0 | The Timer T18 is started when circuit group blocking message is sent. The valid values are 4 to 15 seconds for ANSI and 15 to 60… |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.39 | sonusSs7NodeTimerT19 | 0 | 0 | The Timer T19 is started when initial group blocking message is sent. The valid values are 60 seconds for ANSI and 300 to 900 se… |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.40 | sonusSs7NodeTimerT20 | 0 | 0 | The Timer T20 is started when group unblocking message is sent. The valid ranges are 4 to 15 seconds for ANSI and 15 to 60 secon… |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.41 | sonusSs7NodeTimerT21 | 0 | 0 | The Timer T21 is started when initial group blocking message is sent. The valid values are 60 seconds for ANSI and 300 to 900 se… |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.42 | sonusSs7NodeTimerT22 | 0 | 0 | The Timer T22 is started when circuit group reset message is sent. The valid values are 4 to 15 seconds for ANSI and 15 to 60 se… |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.43 | sonusSs7NodeTimerT23 | 0 | 0 | The Timer T23 is started when initial group reset message is sent. The valid values are 60 seconds for the ANSI and 300 to 900 s… |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.44 | sonusSs7NodeTimerT24 | 0 | 0 | The Timer T24 is started when check tone is sent. The value is less than 2 seconds. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.45 | sonusSs7NodeTimerT25 | 0 | 0 | The Timer T25 is started when initial continuity check failure is detected. The range is 1 to 10 seconds. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.46 | sonusSs7NodeTimerT26 | 0 | 0 | The Timer T26 is started when a second or subsequent continuity failure is detected. The valid value are 60 to 180 seconds. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.47 | sonusSs7NodeTimerT27 | 0 | 0 | The Timer T27 is started when a continuity fail message is recieved. The valid values are more than 180 seconds for ANSI and 240… |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.48 | sonusSs7NodeTimerT28 | 0 | 0 | The Timer T28 is started when Circuit Query Message is sent. The valid value is 10 seconds. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.49 | sonusSs7NodeTimerT29 | 0 | 0 | The Timer T29 is started when Congestion indication is received when T29 is not running. The valid range is 300 to 600 milli sec… |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.50 | sonusSs7NodeTimerT30 | 0 | 0 | The Timer T30 is stared when congestion indication is recieved when T29 is not running. The valid range is 5 to 10 seconds for t… |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.51 | sonusSs7NodeTimerT31 | 0 | 0 | The Timer T31 is started on release of ISUP signalling connection based on CO SCCP. The value should be set to greater than 360 … |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.52 | sonusSs7NodeTimerT32 | 0 | 0 | The Timer T32 is started when the first end-to-end message is recived. Under ANSI this timer is started after the response to su… |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.53 | sonusSs7NodeTimerT33 | 0 | 0 | The Timer T33 is started when Information Request Message is sent. The valid range is 12 to 15 seconds. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.54 | sonusSs7NodeTimerT34 | 0 | 0 | The Timer T34 is started when Loop Back Acknowledgement is sent under ANSI. The Timer T34 is started when segmentation is receiv… |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.55 | sonusSs7NodeTimerT35 | 0 | 0 | The Timer T35 is started when the last digit recieved is not an ST digit or the fixed number of digits have been recieved. This … |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.56 | sonusSs7NodeTimerT36 | 0 | 0 | The Timer T36 is started when IAM is recived with a segmentation indication for ANSI. This timer is started when transit or inco… |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.57 | sonusSs7NodeTimerT37 | 0 | 0 | The Timer T37 is started when User Part Availability test is started under ANSI. This timer is started when a request for and Ec… |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.58 | sonusSs7NodeTimerT38 | 0 | 0 | The Timer T38 is started when a suspend message is sent to the preceding switch. This timer is only relevent under ITU. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.60 | sonusSs7NodeTimerT40 | 0 | 0 | The Timer T40 could be changed from its default using this entry. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.61 | sonusSs7NodeTimerTAcc | 0 | 0 | Automatic Congestion Control Timer as per ANSI T1.113.4 - 1995. The value of the timer is 5 Seconds. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.62 | sonusSs7NodeTimerTCcr | 0 | 0 | Continuity Check Request Timer. The value As per ANSI T1.113.4 - 1995 is 2 Seconds. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.63 | sonusSs7NodeTimerTCcrr | 0 | 0 | Continuity Check Failed Recived. The value as per ANSI T1.113.4 - 1995 is 20 Seconds. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.64 | sonusSs7NodeTimerTCgb | 0 | 0 | Timer started on recipt of a Circuit Group Block Message. The value as per ANSI T1.113.4 - 1995 is 5 Seconds. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.65 | sonusSs7NodeTimerTCra | 0 | 0 | Timer started when Circuit Reservation Acknowledgment is sent. The time value as per ANSI T1.113.4 - 1995 is 20 seconds. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.66 | sonusSs7NodeTimerTCrm | 0 | 0 | This timer is started when the circuit reservation message is sent. The value as per ANSI T1.113.4 - 1995 is 3 - 4 Seconds. The … |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.67 | sonusSs7NodeTimerTCvt | 0 | 0 | The Timer T CVT is started when the Circuit Validation Test message is sent. This message is only valid for ANSI. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.68 | sonusSs7NodeTimerTExm | 0 | 0 | The Timer Exm,d is started when IAM is sent to the succeeding network. This timer has no relevence in the ITU. This timer is in … |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.69 | sonusSs7NodeTimerTGrs | 0 | 0 | This timer is started when a circuit group reset message is received. This timer is only relevent in the ANSI network. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.70 | sonusSs7NodeTimerTHga | 0 | 0 | This timer is started on recognition of carrier loss. It is only relevent in ANSI network. The valid range is 0 to 300 seconds. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.71 | sonusSs7NodeTimerTScga | 0 | 0 | This timer is started when initial demand continuity check fails in the SCGA group. The valid range for this timer is 0 to 120 s… |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.72 | sonusSs7NodeTimerTScgad | 0 | 0 | This timer is started failure of demand continuity check in the SCGA group. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.73 | sonusSs7NodeApplProfileName | 0 | 0 | The SS7 Node Profile to be applied to the node. The values here are a snap shot only and might have changed since they were set. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.74 | sonusSs7NodeNetworkInd | 0 | 0 | The setting of the Network Indicator used for this SS7 Node entry. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.75 | sonusSs7NodeSlsBits | 0 | 0 | The number of SLS bits to use |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.76 | sonusSs7NodeTimerTA | 0 | 0 | The Bellcore specific timer TA is the guard timer on outgoing SS7 circuit before idling. The value of this timer is 0 to 1000 mi… |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.77 | sonusSs7NodeTimerTBlom | 0 | 0 | The Bellcore specific timer TBlom is started when blocking a circuit due to a BLO, and after any call is released; used to notif… |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.78 | sonusSs7NodeTimerTCotd | 0 | 0 | The Bellcore specific timer TCOTd is started when sending IAM requesting continuity check. The value of this timer is in millise… |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.79 | sonusSs7NodeTimerTCotl | 0 | 0 | The Bellcore specific timer TCOTl is started when receiving second COT coded failed, awaiting receipt of CCR. |
1.3.6.1.4.1.2879.2.5.3.1.2.2.1.80 | sonusSs7NodeTimerTSus | 0 | 0 | The Bellcore specific timer TSUS is started when a SUS message is sent by the terminating switch, awaiting called party off-hook… |