The output load has exceeded the UPS output capacity, and the UPS has shut down.
Parsed from file bestpwr.mib.txt
Company: None
Module: BESTPOWER-MIB
The output load has exceeded the UPS output capacity, and the UPS has shut down.
Parsed from file BESTPOWER-MIB.mib
Module: BESTPOWER-MIB
Vendor: Best Power - A Division of General Signal Power Systems
Module: BESTPOWER-MIB
[Automatically extracted from oidview.com]
upsAlarmLowAcOut OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The output load has exceeded the UPS output capacity, and the UPS has shut down." ::= { upsWellKnownAlarms 11 }
upsAlarmLowAcOut OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The output load has exceeded the UPS output capacity, and the UPS has shut down." ::= { upsWellKnownAlarms 11 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2947.1.8.4.11.0 | upsAlarmLowAcOut | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2947.1.8.4.1 | upsAlarmOnBattery | 1 | 1 | The UPS is drawing power from the batteries. |
1.3.6.1.4.1.2947.1.8.4.2 | upsAlarmLowRuntime | 1 | 1 | The remaining battery runtime is less than or equal to the upsConfigLowRuntimeSetpoint. |
1.3.6.1.4.1.2947.1.8.4.3 | upsAlarmNearLowBattery | 1 | 1 | The battery voltage on the UPS has reached a value where the inverter will not be able to function very much longer. |
1.3.6.1.4.1.2947.1.8.4.4 | upsAlarmLowBattery | 1 | 1 | The battery voltage on the UPS has reached a value where the inverter has stopped providing output power to the connected load e… |
1.3.6.1.4.1.2947.1.8.4.5 | upsAlarmHighBattery | 1 | 1 | The battery charger voltage on the UPS has reached a value that is too high for safe battery maintenance. |
1.3.6.1.4.1.2947.1.8.4.6 | upsAlarmCheckBattery | 1 | 1 | The periodic battery test has failed. A manual test of the batteries needs to be performed to determine which battery\batteries… |
1.3.6.1.4.1.2947.1.8.4.7 | upsAlarmReplaceBattery | 1 | 1 | One or more batteries have been determined to require replacement. Compatibility: Fortress II |
1.3.6.1.4.1.2947.1.8.4.8 | upsAlarmCheckInverter | 1 | 1 | The inverter has failed the automatic system test. |
1.3.6.1.4.1.2947.1.8.4.9 | upsAlarmBatteriesDisconnected | 1 | 1 | The UPS has detected that the DC voltage needed to start up is too low or missing. |
1.3.6.1.4.1.2947.1.8.4.10 | upsAlarmOutputOverload | 1 | 1 | The output load exceeds the UPS output capacity. |
1.3.6.1.4.1.2947.1.8.4.12 | upsAlarmCircuitBreakerWarning | 1 | 1 | To much load equipment has been connected to the UPS and has has caused excess current draw from the output. |
1.3.6.1.4.1.2947.1.8.4.13 | upsAlarmCircuitBreakerShdn | 1 | 1 | The UPS has shut down due to an extended excess of current draw from the output. |
1.3.6.1.4.1.2947.1.8.4.14 | upsAlarmBypassOn | 1 | 1 | The Bypass is presently engaged on the UPS. |
1.3.6.1.4.1.2947.1.8.4.15 | upsAlarmAutoBypass | 1 | 1 | The UPS has gone into the Auto Bypass mode to redirect power around the UPS circuitry. |
1.3.6.1.4.1.2947.1.8.4.16 | upsAlarmSiteWiringFault | 1 | 1 | The UPS has found a problem in your wall outlet. |
1.3.6.1.4.1.2947.1.8.4.17 | upsAlarmCheckFan | 1 | 1 | The fan on the UPS has stopped |
1.3.6.1.4.1.2947.1.8.4.18 | upsAlarmHighAmbTemp | 1 | 1 | The internal temperature inside the UPS is too hot. |
1.3.6.1.4.1.2947.1.8.4.19 | upsAlarmHighHSTemp | 1 | 1 | The Inverter heatsink assembly inside the UPS is to hot . |
1.3.6.1.4.1.2947.1.8.4.20 | upsAlarmHighXFMRTemp | 1 | 1 | The temperature of the main transformer inside the UPS is too hot . |
1.3.6.1.4.1.2947.1.8.4.21 | upsAlarmHighPFMTemp | 1 | 1 | The temperature of the PFM module inside the UPS is too hot . |
1.3.6.1.4.1.2947.1.8.4.22 | upsAlarmProbeMissing | 1 | 1 | One or all of the sense probes has been disconnected on the UPS. |
1.3.6.1.4.1.2947.1.8.4.23 | upsAlarmCheckPowerSupply | 1 | 1 | The internal DC supply voltages are attenuated or missing. |
1.3.6.1.4.1.2947.1.8.4.24 | upsAlarmTapRegulator | 1 | 1 | The UPS detected a possible failure in the tap changer (open or welded relay, etc.) |
1.3.6.1.4.1.2947.1.8.4.25 | upsAlarmRelayFailure | 1 | 1 | There is a hardware problem inside the UPS. |
1.3.6.1.4.1.2947.1.8.4.26 | upsAlarmCheckFuse | 1 | 1 | The failure of one or more fuses has been detected. |
1.3.6.1.4.1.2947.1.8.4.27 | upsAlarmCheckMOV | 1 | 1 | One or more MOVs have failed due to a voltage surge. |
1.3.6.1.4.1.2947.1.8.4.28 | upsAlarmMemoryError | 1 | 1 | The UPS has lost the programmed settings in the memory of the logic board. |
1.3.6.1.4.1.2947.1.8.4.29 | upsAlarmCallService | 1 | 1 | A hardware malfunction has occurred inside the UPS. Please consult a factory authorized service representative for assistance. |
1.3.6.1.4.1.2947.1.8.4.30 | upsAlarmupsFailed | 1 | 1 | A general fault in the UPS has been detected. |
1.3.6.1.4.1.2947.1.8.4.31 | upsAlarmUserTest | 1 | 1 | A user test of the alarm beeper is in progress. |
1.3.6.1.4.1.2947.1.8.4.32 | upsAlarmTestInProgress | 1 | 1 | A test is in progress. |
1.3.6.1.4.1.2947.1.8.4.33 | upsAlarmDiagnosticTestFailed | 1 | 1 | The result of the last diagnostic test indicates a failure. |
1.3.6.1.4.1.2947.1.8.4.34 | upsAlarmEPO | 1 | 1 | The Emergency Power OFF feature has been activiated at the RS-232 port on the UPS. |
1.3.6.1.4.1.2947.1.8.4.35 | upsAlarmUpsOff | 1 | 1 | The output of the UPS is in the off state. |
1.3.6.1.4.1.2947.1.8.4.36 | upsAlarmCommunicationsLost | 1 | 1 | A problem has been encountered in the communications between the agent and the UPS. |