Reference record for OID 1.3.6.1.4.1.318.1.1.1.7.2.5



parent
1.3.6.1.4.1.318.1.1.1.7.2 (upsAdvTest)
node code
5
node name
upsAdvTestRuntimeCalibration
dot oid
1.3.6.1.4.1.318.1.1.1.7.2.5
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) ups(1) upsTest(7) upsAdvTest(2) upsAdvTestRuntimeCalibration(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) ups(1) upsTest(7) upsAdvTest(2) upsAdvTestRuntimeCalibration(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) ups(1) upsTest(7) upsAdvTest(2) upsAdvTestRuntimeCalibration(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) ups(1) upsTest(7) upsAdvTest(2) upsAdvTestRuntimeCalibration(5)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) ups(1) upsTest(7) upsAdvTest(2) upsAdvTestRuntimeCalibration(5)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) ups(1) upsTest(7) upsAdvTest(2) upsAdvTestRuntimeCalibration(5)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/apc/products/hardware/ups/upsTest/upsAdvTest/upsAdvTestRuntimeCalibration
  • /iso/identified-organization/dod/internet/private/enterprises/apc/products/hardware/ups/upsTest/upsAdvTest/upsAdvTestRuntimeCalibration
  • /iso/org/dod/internet/private/enterprise/apc/products/hardware/ups/upsTest/upsAdvTest/upsAdvTestRuntimeCalibration
  • /iso/org/dod/internet/private/enterprises/apc/products/hardware/ups/upsTest/upsAdvTest/upsAdvTestRuntimeCalibration
  • /iso/iso-identified-organization/dod/internet/private/enterprise/apc/products/hardware/ups/upsTest/upsAdvTest/upsAdvTestRuntimeCalibration
  • /iso/iso-identified-organization/dod/internet/private/enterprises/apc/products/hardware/ups/upsTest/upsAdvTest/upsAdvTestRuntimeCalibration
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/318/1/1/1/7/2/5

    Description by mibdepot

    Setting this variable to performCalibration(2) causes
    the UPS to discharge to calibrate the UPS.
    The test will only start if the battery capacity is 100%.
    The test runs until capacity is less than 25%.

    Setting this variable to cancelCurrentCalibration(3)
    after setting performCalibration(2) will cancel the
    current discharge.

    Setting this variable to noPerformCalibration(1)
    will have no effect.

    The value noPerformCalibration(1) will always be returned
    when the variable is read.

    The result of the calibration will be saved in
    upsAdvTestCalibrationResult.

    Parsed from file powernet.mib.txt
    Company: None
    Module: PowerNet-MIB

    Description by circitor

    Setting this variable to performCalibration(2) causes
    the UPS to discharge to calibrate the UPS.
    The test will only start if the battery capacity is 100%.
    The test runs until capacity is less than 25%.

    Setting this variable to cancelCurrentCalibration(3)
    after setting performCalibration(2) will cancel the
    current discharge.

    Setting this variable to noPerformCalibration(1)
    will have no effect.

    The value noPerformCalibration(1) will always be returned
    when the variable is read.

    The result of the calibration will be saved in
    upsAdvTestCalibrationResult.

    Parsed from file PowerNet-MIB.mib
    Module: PowerNet-MIB

    Information by mibdepot

    upsAdvTestRuntimeCalibration OBJECT-TYPE SYNTAX INTEGER { noPerformCalibration(1), performCalibration(2), cancelCurrentCalibration(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this variable to performCalibration(2) causes the UPS to discharge to calibrate the UPS. The test will only start if the battery capacity is 100%. The test runs until capacity is less than 25%. Setting this variable to cancelCurrentCalibration(3) after setting performCalibration(2) will cancel the current discharge. Setting this variable to noPerformCalibration(1) will have no effect. The value noPerformCalibration(1) will always be returned when the variable is read. The result of the calibration will be saved in upsAdvTestCalibrationResult." ::= { upsAdvTest 5 }

    Information by oid_info

    Vendor: American Power Conversion Corp.
    Module: PowerNet-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    upsAdvTestRuntimeCalibration OBJECT-TYPE SYNTAX INTEGER { noPerformCalibration(1), performCalibration(2), cancelCurrentCalibration(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this variable to performCalibration(2) causes the UPS to discharge to calibrate the UPS. The test will only start if the battery capacity is 100%. The test runs until capacity is less than 25%. Setting this variable to cancelCurrentCalibration(3) after setting performCalibration(2) will cancel the current discharge. Setting this variable to noPerformCalibration(1) will have no effect. The value noPerformCalibration(1) will always be returned when the variable is read. The result of the calibration will be saved in upsAdvTestCalibrationResult." ::= { upsAdvTest 5 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.318)

    Yoest Peter C.

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.318.1.1.1.7.2.5.0 upsAdvTestRuntimeCalibration 0 0 None

    Brothers (8)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.318.1.1.1.7.2.1 upsAdvTestDiagnosticSchedule 1 1 The UPS system's automatic battery test schedule.
    1.3.6.1.4.1.318.1.1.1.7.2.2 upsAdvTestDiagnostics 1 1 Setting this variable to testDiagnostics(2) causes
    the UPS to perform a diagnostic self test.

    Setting this value to noTestDiagno…
    1.3.6.1.4.1.318.1.1.1.7.2.3 upsAdvTestDiagnosticsResults 1 1 The results of the last UPS diagnostics test performed.
    1.3.6.1.4.1.318.1.1.1.7.2.4 upsAdvTestLastDiagnosticsDate 1 1 The date the last UPS diagnostics test was performed in
    mm/dd/yy format.
    1.3.6.1.4.1.318.1.1.1.7.2.6 upsAdvTestCalibrationResults 1 1 The results of the last runtime calibration.

    Value ok(1) means a successful runtime calibration.

    Value invalidCalibration(2) in…
    1.3.6.1.4.1.318.1.1.1.7.2.7 upsAdvTestCalibrationDate 1 1 The date the last UPS runtime calibration was
    performed in mm/dd/yy format.
    1.3.6.1.4.1.318.1.1.1.7.2.8 upsAdvTestDiagnosticTime 1 1 The time of the day to perform automatic battery test.
    Expressed in 24 hour notation - hh:mm.
    1.3.6.1.4.1.318.1.1.1.7.2.9 upsAdvTestDiagnosticDay 1 1 The day of the week to perform automatic battery test.