The monitor wire length:
fiftyFeetOrLess (1) indicates that the wire length is less than or equal to 50 feet.
moreThanFiftyFeet (2) indicates that the wire length is greater than 50 feet.
Parsed from file powernet.mib.txt
Company: None
Module: PowerNet-MIB
The monitor wire length:
fiftyFeetOrLess (1) indicates that the wire length is less than or equal to 50 feet.
moreThanFiftyFeet (2) indicates that the wire length is greater than 50 feet.
Parsed from file PowerNet-MIB.mib
Module: PowerNet-MIB
battManConfigMonitorWireLength OBJECT-TYPE SYNTAX INTEGER { fiftyFeetOrLess (1), moreThanFiftyFeet (2) } ACCESS read-write STATUS mandatory DESCRIPTION "The monitor wire length: fiftyFeetOrLess (1) indicates that the wire length is less than or equal to 50 feet. moreThanFiftyFeet (2) indicates that the wire length is greater than 50 feet." ::= { battManConfig 17 }
Vendor: American Power Conversion Corp.
Module: PowerNet-MIB
[Automatically extracted from oidview.com]
battManConfigMonitorWireLength OBJECT-TYPE SYNTAX INTEGER { fiftyFeetOrLess (1), moreThanFiftyFeet (2) } ACCESS read-write STATUS mandatory DESCRIPTION "The monitor wire length: fiftyFeetOrLess (1) indicates that the wire length is less than or equal to 50 feet. moreThanFiftyFeet (2) indicates that the wire length is greater than 50 feet." ::= { battManConfig 17 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.318.1.1.16.6.17.0 | battManConfigMonitorWireLength | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.318.1.1.16.6.1 | battManConfigApplication | 1 | 1 | This OID has been deprecated. |
1.3.6.1.4.1.318.1.1.16.6.2 | battManConfigBatteryChemistry | 1 | 1 | The battery chemistry of the monitored batteries: LeadAcid(1) Lead Acid or Nickel-Cadmium(2) Nickel-Cadmium. |
1.3.6.1.4.1.318.1.1.16.6.3 | battManConfigBatteryAHCapacity | 1 | 1 | The amp hour capacity of the monitored batteries 5-4000 AH. |
1.3.6.1.4.1.318.1.1.16.6.4 | battManConfigNumberofStrings | 1 | 1 | The number of strings in the battery manager system. |
1.3.6.1.4.1.318.1.1.16.6.5 | battManConfigBatteriesperString | 1 | 1 | The number of batteries per string. |
1.3.6.1.4.1.318.1.1.16.6.6 | battManConfigCellsperBattery | 1 | 1 | The number of cells per battery (1 - 6 for lead-acid, 1 - 2 for NiCd. |
1.3.6.1.4.1.318.1.1.16.6.7 | battManConfigMinCellVoltage | 1 | 1 | The minimum battery cell voltage alarm limit in millivolts DC. |
1.3.6.1.4.1.318.1.1.16.6.8 | battManConfigMaxCellVoltage | 1 | 1 | The maximum battery cell voltage alarm limit in millivolts DC. |
1.3.6.1.4.1.318.1.1.16.6.9 | battManConfigMaxPilotTempF | 1 | 1 | The maximum pilot battery temperature alarm limit in tenths of degrees Fahrenheit. |
1.3.6.1.4.1.318.1.1.16.6.10 | battManConfigMaxPilotTempC | 1 | 1 | The maximum pilot battery temperature alarm limit in tenths of degrees Celsius. |
1.3.6.1.4.1.318.1.1.16.6.11 | battManConfigMaxAmbientTempF | 1 | 1 | The maximum ambient temperature alarm limit in tenths of degrees Fahrenheit. |
1.3.6.1.4.1.318.1.1.16.6.12 | battManConfigMaxAmbientTempC | 1 | 1 | The maximum ambient temperature alarm limit in tenths of degrees Celsius. |
1.3.6.1.4.1.318.1.1.16.6.13 | battManConfigMinAmbientTempF | 1 | 1 | The Minimum Ambient Temperature alarm limit in tenths of degrees Fahrenheit. |
1.3.6.1.4.1.318.1.1.16.6.14 | battManConfigMinAmbientTempC | 1 | 1 | The Minimum Ambient Temperature alarm limit in tenths of degrees Celsius. |
1.3.6.1.4.1.318.1.1.16.6.15 | battManConfigMaxRippleCurrent | 1 | 1 | The maximum ripple current alarm limit for the monitored battery strings in percent of AH capacity. |
1.3.6.1.4.1.318.1.1.16.6.16 | battManConfigMaxCurrentAcceptanceDeviation | 1 | 1 | The maximum current acceptance deviation alarm limit in percent. |
1.3.6.1.4.1.318.1.1.16.6.18 | battManConfigDischargeVoltageAlarmLevel | 1 | 1 | The discharge voltage alarm level in percent. |
1.3.6.1.4.1.318.1.1.16.6.19 | battManConfigAutoAnnunciatorReset | 1 | 1 | The annunciator output signal reset method: disabled(1) means the annunciator signal output will be reset when the reset button … |
1.3.6.1.4.1.318.1.1.16.6.20 | battManConfigSuspendCellVoltage | 1 | 1 | This is used along with the number of cells per battery and the number of batteries per string to determine if a battery string h… |
1.3.6.1.4.1.318.1.1.16.6.21 | battManConfigOhmicTestWaitTime | 1 | 1 | The amount of time in seconds after a discharge event before data will be collected for the ohmic value calculation. |
1.3.6.1.4.1.318.1.1.16.6.22 | battManConfigNumberOfBoosts | 1 | 1 | The number of consecutive times the Battery Management System applies a charge to each battery during a boost cycle. Batteries w… |