Ambient high temperature threshold. Temperature sensor located on Master
Controller board.
Values are represented in thousandths of a degree.
Units are displayed in the scale shown in
the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit).
Attempts to set the value above or below the acceptable range of the powerplant
will cause the value to be set at the high or low point of the range respectively.
Parsed from file powernet.mib.txt
Company: None
Module: PowerNet-MIB
dm3ConfigSysHightempThresh
View at oid-info.com
Ambient high temperature threshold. Temperature sensor located on Master
Controller board.
Values are represented in thousandths of a degree.
Units are displayed in the scale shown in
the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit).
Attempts to set the value above or below the acceptable range of the powerplant
will cause the value to be set at the high or low point of the range respectively.
Parsed from file PowerNet-MIB.mib
Module: PowerNet-MIB
dm3ConfigSysHighTempThresh OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Ambient high temperature threshold. Temperature sensor located on Master Controller board. Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively." ::= { dm3ConfigSystem 3 }
Vendor: American Power Conversion Corp.
Module: PowerNet-MIB
[Automatically extracted from oidview.com]
dm3ConfigSysHighTempThresh OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Ambient high temperature threshold. Temperature sensor located on Master Controller board. Values are represented in thousandths of a degree. Units are displayed in the scale shown in the 'dm3StatusSysTempUnits' OID (Celsius or Fahrenheit). Attempts to set the value above or below the acceptable range of the powerplant will cause the value to be set at the high or low point of the range respectively." ::= { dm3ConfigSystem 3 }
| OID | Name | Sub children | Sub Nodes Total | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.318.1.1.7.2.1.3.0 | dm3ConfigSysHighTempThresh | 0 | 0 | dm3ConfigSysHightempThresh |
| OID | Name | Sub children | Sub Nodes Total | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.318.1.1.7.2.1.1 | dm3ConfigSysDescriptionTableSize | 1 | 1 | The number of DC description records. |
| 1.3.6.1.4.1.318.1.1.7.2.1.2 | dm3ConfigSysDescriptionTable | 1 | 3 | Allows for accessing description records of the powerplant. The number of entries is contained in the dm3ConfigSysDescriptionTab… |
| 1.3.6.1.4.1.318.1.1.7.2.1.4 | dm3ConfigSysHighTempAlarm | 1 | 1 | dm3ConfigSysHightempAlarm |
| 1.3.6.1.4.1.318.1.1.7.2.1.5 | dm3ConfigSysLowTempThresh | 1 | 1 | Ambient low temperature threshold. Temperature sensor located on Master Controller board. Values are represented in thousandths… |
| 1.3.6.1.4.1.318.1.1.7.2.1.6 | dm3ConfigSysLowTempAlarm | 1 | 1 | For the System Low Temperature Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting t… |
| 1.3.6.1.4.1.318.1.1.7.2.1.7 | dm3ConfigSysHardwareTempAlarm | 1 | 1 | For the System Hardware Temperature Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Sett… |
| 1.3.6.1.4.1.318.1.1.7.2.1.8 | dm3ConfigSysRemoteAccess | 1 | 1 | This OID is used to disable remote write access to the power plant. Setting this OID to accessEnabled (1) will have no affect. Se… |