For the System Low Temperature Alarm;
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
alarm condition.
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
alarm condition.
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
alarm condition.
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
alarm condition.
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
alarm condition.
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
alarm condition.
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
alarm condition.
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
alarm condition.
Parsed from file powernet.mib.txt
Company: None
Module: PowerNet-MIB
For the System Low Temperature Alarm;
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
alarm condition.
Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
alarm condition.
Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
alarm condition.
Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
alarm condition.
Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
alarm condition.
Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
alarm condition.
Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
alarm condition.
Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
alarm condition.
Parsed from file PowerNet-MIB.mib
Module: PowerNet-MIB
dm3ConfigSysLowTempAlarm OBJECT-TYPE SYNTAX INTEGER { alarmIgnore (1), alarmRelay1 (2), alarmRelay2 (3), alarmRelay3 (4), alarmRelay4 (5), alarmRelay5 (6), alarmRelay6 (7), alarmMinor (8), alarmMajor (9) } ACCESS read-write STATUS mandatory DESCRIPTION "For the System Low Temperature Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition." ::= { dm3ConfigSystem 6 }
Vendor: American Power Conversion Corp.
Module: PowerNet-MIB
[Automatically extracted from oidview.com]
dm3ConfigSysLowTempAlarm OBJECT-TYPE SYNTAX INTEGER { alarmIgnore (1), alarmRelay1 (2), alarmRelay2 (3), alarmRelay3 (4), alarmRelay4 (5), alarmRelay5 (6), alarmRelay6 (7), alarmMinor (8), alarmMajor (9) } ACCESS read-write STATUS mandatory DESCRIPTION "For the System Low Temperature Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition." ::= { dm3ConfigSystem 6 }
| OID | Name | Sub children | Sub Nodes Total | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.318.1.1.7.2.1.6.0 | dm3ConfigSysLowTempAlarm | 0 | 0 | None |
| OID | Name | Sub children | Sub Nodes Total | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.318.1.1.7.2.1.1 | dm3ConfigSysDescriptionTableSize | 1 | 1 | The number of DC description records. |
| 1.3.6.1.4.1.318.1.1.7.2.1.2 | dm3ConfigSysDescriptionTable | 1 | 3 | Allows for accessing description records of the powerplant. The number of entries is contained in the dm3ConfigSysDescriptionTab… |
| 1.3.6.1.4.1.318.1.1.7.2.1.3 | dm3ConfigSysHighTempThresh | 1 | 1 | dm3ConfigSysHightempThresh |
| 1.3.6.1.4.1.318.1.1.7.2.1.4 | dm3ConfigSysHighTempAlarm | 1 | 1 | dm3ConfigSysHightempAlarm |
| 1.3.6.1.4.1.318.1.1.7.2.1.5 | dm3ConfigSysLowTempThresh | 1 | 1 | Ambient low temperature threshold. Temperature sensor located on Master Controller board. Values are represented in thousandths… |
| 1.3.6.1.4.1.318.1.1.7.2.1.7 | dm3ConfigSysHardwareTempAlarm | 1 | 1 | For the System Hardware Temperature Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Sett… |
| 1.3.6.1.4.1.318.1.1.7.2.1.8 | dm3ConfigSysRemoteAccess | 1 | 1 | This OID is used to disable remote write access to the power plant. Setting this OID to accessEnabled (1) will have no affect. Se… |