Reference record for OID 1.3.6.1.4.1.318.1.1.7.2.4.1.2.2



parent
1.3.6.1.4.1.318.1.1.7.2.4.1.2 (dm3ConfigRectAlarms)
node code
2
node name
dm3ConfigRectLowVoltAlarm
dot oid
1.3.6.1.4.1.318.1.1.7.2.4.1.2.2
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) dcDM3(7) dm3Config(2) dm3ConfigPowerModules(4) dm3ConfigRectifier(1) dm3ConfigRectAlarms(2) dm3ConfigRectLowVoltAlarm(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) dcDM3(7) dm3Config(2) dm3ConfigPowerModules(4) dm3ConfigRectifier(1) dm3ConfigRectAlarms(2) dm3ConfigRectLowVoltAlarm(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) dcDM3(7) dm3Config(2) dm3ConfigPowerModules(4) dm3ConfigRectifier(1) dm3ConfigRectAlarms(2) dm3ConfigRectLowVoltAlarm(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) dcDM3(7) dm3Config(2) dm3ConfigPowerModules(4) dm3ConfigRectifier(1) dm3ConfigRectAlarms(2) dm3ConfigRectLowVoltAlarm(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) dcDM3(7) dm3Config(2) dm3ConfigPowerModules(4) dm3ConfigRectifier(1) dm3ConfigRectAlarms(2) dm3ConfigRectLowVoltAlarm(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) dcDM3(7) dm3Config(2) dm3ConfigPowerModules(4) dm3ConfigRectifier(1) dm3ConfigRectAlarms(2) dm3ConfigRectLowVoltAlarm(2)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/apc/products/hardware/dcDM3/dm3Config/dm3ConfigPowerModules/dm3ConfigRectifier/dm3ConfigRectAlarms/dm3ConfigRectLowVoltAlarm
  • /iso/identified-organization/dod/internet/private/enterprises/apc/products/hardware/dcDM3/dm3Config/dm3ConfigPowerModules/dm3ConfigRectifier/dm3ConfigRectAlarms/dm3ConfigRectLowVoltAlarm
  • /iso/org/dod/internet/private/enterprise/apc/products/hardware/dcDM3/dm3Config/dm3ConfigPowerModules/dm3ConfigRectifier/dm3ConfigRectAlarms/dm3ConfigRectLowVoltAlarm
  • /iso/org/dod/internet/private/enterprises/apc/products/hardware/dcDM3/dm3Config/dm3ConfigPowerModules/dm3ConfigRectifier/dm3ConfigRectAlarms/dm3ConfigRectLowVoltAlarm
  • /iso/iso-identified-organization/dod/internet/private/enterprise/apc/products/hardware/dcDM3/dm3Config/dm3ConfigPowerModules/dm3ConfigRectifier/dm3ConfigRectAlarms/dm3ConfigRectLowVoltAlarm
  • /iso/iso-identified-organization/dod/internet/private/enterprises/apc/products/hardware/dcDM3/dm3Config/dm3ConfigPowerModules/dm3ConfigRectifier/dm3ConfigRectAlarms/dm3ConfigRectLowVoltAlarm
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/318/1/1/7/2/4/1/2/2

    Description by mibdepot

    For the Rectifier Low Voltage Alarm;
    Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
    Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
    alarm condition.
    Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
    alarm condition.
    Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
    alarm condition.
    Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
    alarm condition.
    Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
    alarm condition.
    Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
    alarm condition.
    Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
    alarm condition.
    Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
    alarm condition.

    Parsed from file powernet.mib.txt
    Company: None
    Module: PowerNet-MIB

    Description by circitor

    For the Rectifier Low Voltage Alarm;
    Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
    Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an
    alarm condition.
    Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an
    alarm condition.
    Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an
    alarm condition.
    Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an
    alarm condition.
    Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an
    alarm condition.
    Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an
    alarm condition.
    Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an
    alarm condition.
    Setting this OID to alarmMajor (9) causes the Major relay to be activated for an
    alarm condition.

    Parsed from file PowerNet-MIB.mib
    Module: PowerNet-MIB

    Information by mibdepot

    dm3ConfigRectLowVoltAlarm OBJECT-TYPE SYNTAX INTEGER { alarmIgnore (1), alarmRelay1 (2), alarmRelay2 (3), alarmRelay3 (4), alarmRelay4 (5), alarmRelay5 (6), alarmRelay6 (7), alarmMinor (8), alarmMajor (9) } ACCESS read-write STATUS mandatory DESCRIPTION "For the Rectifier Low Voltage Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition." ::= { dm3ConfigRectAlarms 2 }

    Information by oid_info

    Vendor: American Power Conversion Corp.
    Module: PowerNet-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    dm3ConfigRectLowVoltAlarm OBJECT-TYPE SYNTAX INTEGER { alarmIgnore (1), alarmRelay1 (2), alarmRelay2 (3), alarmRelay3 (4), alarmRelay4 (5), alarmRelay5 (6), alarmRelay6 (7), alarmMinor (8), alarmMajor (9) } ACCESS read-write STATUS mandatory DESCRIPTION "For the Rectifier Low Voltage Alarm; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to alarmRelay2 (3) causes relay 2 to be activated for an alarm condition. Setting this OID to alarmRelay3 (4) causes relay 3 to be activated for an alarm condition. Setting this OID to alarmRelay4 (5) causes relay 4 to be activated for an alarm condition. Setting this OID to alarmRelay5 (6) causes relay 5 to be activated for an alarm condition. Setting this OID to alarmRelay6 (7) causes relay 6 to be activated for an alarm condition. Setting this OID to alarmMinor (8) causes the Minor relay to be activated for an alarm condition. Setting this OID to alarmMajor (9) causes the Major relay to be activated for an alarm condition." ::= { dm3ConfigRectAlarms 2 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.318)

    Yoest Peter C.

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.318.1.1.7.2.4.1.2.2.0 dm3ConfigRectLowVoltAlarm 0 0 None

    Brothers (11)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.318.1.1.7.2.4.1.2.1 dm3ConfigRectHighVoltAlarm 1 1 For the Rectifier High Voltage Alarm;
    Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
    Setting t…
    1.3.6.1.4.1.318.1.1.7.2.4.1.2.3 dm3ConfigRectConfigAlarm 1 1 This alarm is activated when a new rectifier is detected;
    Setting this OID to alarmIgnore (1) results in the alarm condition bei…
    1.3.6.1.4.1.318.1.1.7.2.4.1.2.4 dm3ConfigRect1ofNAlarm 1 1 This setting indicates the action if ONE rectifier of a N+1 system has failed;
    Setting this OID to alarmIgnore (1) results in th…
    1.3.6.1.4.1.318.1.1.7.2.4.1.2.5 dm3ConfigRect2ofNAlarm 1 1 This setting indicates the action if TWO OR MORE rectifiers of a N+1 system have failed;
    Setting this OID to alarmIgnore (1) res…
    1.3.6.1.4.1.318.1.1.7.2.4.1.2.6 dm3ConfigRectDiagAlarm 1 1 For the Rectifier Controller Diagnostics Alarm;
    Setting this OID to alarmIgnore (1) results in the alarm condition being ignored…
    1.3.6.1.4.1.318.1.1.7.2.4.1.2.7 dm3ConfigRectImbalanceAlarm 1 1 For the Rectifier Imbalance Alarm;
    Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
    Setting this…
    1.3.6.1.4.1.318.1.1.7.2.4.1.2.8 dm3ConfigRectCurrLimitAlarm 1 1 For the Rectifier Current Limit Alarm (indicating rectifier in the Current Limit state);
    Setting this OID to alarmIgnore (1) res…
    1.3.6.1.4.1.318.1.1.7.2.4.1.2.9 dm3ConfigRectStandbyAlarm 1 1 For the Rectifier Standby Alarm (indicating output DC has been turned off);
    Setting this OID to alarmIgnore (1) results in the a…
    1.3.6.1.4.1.318.1.1.7.2.4.1.2.10 dm3ConfigRectFanFailAlarm 1 1 For the Rectifier Fan Fail Alarm;
    Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
    Setting this …
    1.3.6.1.4.1.318.1.1.7.2.4.1.2.11 dm3ConfigRectFailAlarm 1 1 For the Rectifier Fail Alarm;
    Setting this OID to alarmIgnore (1) results in the alarm condition being ignored.
    Setting this OID …
    1.3.6.1.4.1.318.1.1.7.2.4.1.2.12 dm3ConfigRectHwVoltAlarm 1 1 For the Rectifier Hardware Voltage Alarm (indicating voltage outside realistic limits,
    or a possible measurement fault);
    Setting …