The name used to identify the zone where the equipment
resides.
        
            
            Parsed from file mrvInReach.mib.txt
            
            Company: None
            
            Module: MRVINREACH
        
        
The name used to identify the zone where the equipment
resides.
        
            
            Parsed from file MRVINREACH.mib
            
            Module: MRVINREACH
        
        
basicAlarmMasterInputZone OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "The name used to identify the zone where the equipment resides." ::= { basicAlarmMasterInputEntry 14 }
Vendor: MRV Communications, In-Reach Product Division
Module: MRV-IN-REACH-CHARACTER-MIB
[Automatically extracted from oidview.com]
basicAlarmMasterInputZone OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "The name used to identify the zone where the equipment resides." ::= { basicAlarmMasterInputEntry 14 }
| OID | Name | Sub children | Sub Nodes Total | Description | 
|---|---|---|---|---|
| 1.3.6.1.4.1.33.13.1.36.1.1 | basicAlarmMasterInputPort | 0 | 0 | An index value that uniquely identifies a port. The port identified by a particular value of this index is the same port as ident… | 
| 1.3.6.1.4.1.33.13.1.36.1.2 | basicAlarmMasterInputSlot | 0 | 0 | An index value that uniquely identifies a slot of alarm points on a given high density alarm port. | 
| 1.3.6.1.4.1.33.13.1.36.1.3 | basicAlarmMasterInputPoint | 0 | 0 | An index value that uniquely identifies an alarm point within an alarm slot on a high density alarm port. | 
| 1.3.6.1.4.1.33.13.1.36.1.4 | basicAlarmMasterInputName | 0 | 0 | The name used to identify this alarm point. | 
| 1.3.6.1.4.1.33.13.1.36.1.5 | basicAlarmMasterInputTrapEnable | 0 | 0 | Control to send a trap when the alarm input changes state. | 
| 1.3.6.1.4.1.33.13.1.36.1.6 | basicAlarmMasterControlOutputSignal | 0 | 0 | Control to toggle the output signal for an alarm point. | 
| 1.3.6.1.4.1.33.13.1.36.1.7 | basicAlarmMasterInputEnable | 0 | 0 | Control to toggle whether this alarm point is active. | 
| 1.3.6.1.4.1.33.13.1.36.1.8 | basicAlarmMasterInputDebounceInterval | 0 | 0 | Amount of time in seconds to debounce a signal change before triggering an alarm. | 
| 1.3.6.1.4.1.33.13.1.36.1.9 | basicAlarmMasterInputFaultSeverity | 0 | 0 | Control to determine the severity level associated with the trap sent out when a fault occurs for this alarm input point. | 
| 1.3.6.1.4.1.33.13.1.36.1.10 | basicAlarmMasterInputFaultState | 0 | 0 | Control to indicate which state, open or closed, represents the fault condition for this alarm input point. The other state is th… | 
| 1.3.6.1.4.1.33.13.1.36.1.11 | basicAlarmMasterInputStatus | 0 | 0 | Indicates the current status of the alarm input point. If the basicAlarmMasterInputValue matches the fault state, then the status… | 
| 1.3.6.1.4.1.33.13.1.36.1.12 | basicAlarmMasterInputValue | 0 | 0 | Indicates the current state of the alarm input point. | 
| 1.3.6.1.4.1.33.13.1.36.1.13 | basicAlarmMasterDisplay | 0 | 0 | Control to toggle the display of the alarm status for this point in the display window of the high density alarm unit. | 
| 1.3.6.1.4.1.33.13.1.36.1.15 | basicAlarmMasterInputRelatedEquipment | 0 | 0 | The name used to identify related equipment. | 
| 1.3.6.1.4.1.33.13.1.36.1.16 | basicAlarmMasterInputSiteId | 0 | 0 | The name used to identify the site where the unit resides. | 
| 1.3.6.1.4.1.33.13.1.36.1.17 | basicAlarmMasterInputManufacturer | 0 | 0 | The name used to identify the manufacturer of this equipment. | 
| 1.3.6.1.4.1.33.13.1.36.1.18 | basicAlarmMasterInputModel | 0 | 0 | The model name of this equipment. |