Control to toggle the output signal for an alarm point.
Parsed from file it-character-mib.mib.txt
Company: None
Module: ITOUCH-CHARACTER-MIB
Control to toggle the output signal for an alarm point.
Parsed from file MRVINREACH.mib
Module: MRVINREACH
basicAlarmMasterControlOutputSignal OBJECT-TYPE SYNTAX INTEGER { open (1), closed (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Control to toggle the output signal for an alarm point." DEFVAL { open } ::= { basicAlarmMasterInputEntry 6 }
Vendor: MRV Communications, In-Reach Product Division
Module: ITOUCH-CHARACTER-MIB
[Automatically extracted from oidview.com]
basicAlarmMasterControlOutputSignal OBJECT-TYPE SYNTAX INTEGER { open (1), closed (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Control to toggle the output signal for an alarm point." DEFVAL { open } ::= { basicAlarmMasterInputEntry 6 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.33.13.1.36.1.1 | basicAlarmMasterInputPort | 0 | 0 | An index value that uniquely identifies a port. The port identified by a particular value of this index is the same port as ident… |
1.3.6.1.4.1.33.13.1.36.1.2 | basicAlarmMasterInputSlot | 0 | 0 | An index value that uniquely identifies a slot of alarm points on a given high density alarm port. |
1.3.6.1.4.1.33.13.1.36.1.3 | basicAlarmMasterInputPoint | 0 | 0 | An index value that uniquely identifies an alarm point within an alarm slot on a high density alarm port. |
1.3.6.1.4.1.33.13.1.36.1.4 | basicAlarmMasterInputName | 0 | 0 | The name used to identify this alarm point. |
1.3.6.1.4.1.33.13.1.36.1.5 | basicAlarmMasterInputTrapEnable | 0 | 0 | Control to send a trap when the alarm input changes state. |
1.3.6.1.4.1.33.13.1.36.1.7 | basicAlarmMasterInputEnable | 0 | 0 | Control to toggle whether this alarm point is active. |
1.3.6.1.4.1.33.13.1.36.1.8 | basicAlarmMasterInputDebounceInterval | 0 | 0 | Amount of time in seconds to debounce a signal change before triggering an alarm. |
1.3.6.1.4.1.33.13.1.36.1.9 | basicAlarmMasterInputFaultSeverity | 0 | 0 | Control to determine the severity level associated with the trap sent out when a fault occurs for this alarm input point. |
1.3.6.1.4.1.33.13.1.36.1.10 | basicAlarmMasterInputFaultState | 0 | 0 | Control to indicate which state, open or closed, represents the fault condition for this alarm input point. The other state is th… |
1.3.6.1.4.1.33.13.1.36.1.11 | basicAlarmMasterInputStatus | 0 | 0 | Indicates the current status of the alarm input point. If the basicAlarmMasterInputValue matches the fault state, then the status… |
1.3.6.1.4.1.33.13.1.36.1.12 | basicAlarmMasterInputValue | 0 | 0 | Indicates the current state of the alarm input point. |
1.3.6.1.4.1.33.13.1.36.1.13 | basicAlarmMasterDisplay | 0 | 0 | Control to toggle the display of the alarm status for this point in the display window of the high density alarm unit. |
1.3.6.1.4.1.33.13.1.36.1.14 | basicAlarmMasterInputZone | 0 | 0 | The name used to identify the zone where the equipment resides. |
1.3.6.1.4.1.33.13.1.36.1.15 | basicAlarmMasterInputRelatedEquipment | 0 | 0 | The name used to identify related equipment. |
1.3.6.1.4.1.33.13.1.36.1.16 | basicAlarmMasterInputSiteId | 0 | 0 | The name used to identify the site where the unit resides. |
1.3.6.1.4.1.33.13.1.36.1.17 | basicAlarmMasterInputManufacturer | 0 | 0 | The name used to identify the manufacturer of this equipment. |
1.3.6.1.4.1.33.13.1.36.1.18 | basicAlarmMasterInputModel | 0 | 0 | The model name of this equipment. |