Bbd rule entry.
Parsed from file it-router-12.mib.txt
Company: inreach
Module: IT-ROUTER-12
xBbdConfigEntry OBJECT-TYPE SYNTAX XBbdConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Bbd rule entry." INDEX { xBbdIndex } ::= { xBbdConfigTable 1 }
Vendor: In-Reach
Module: IT-ROUTER-12 (it-router-12.mib)
Type: ENTRY
Access: not-accessible
Syntax: XBbdConfigEntry
Automatically extracted from www.mibdepot.com
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.33.24.7.2.1.1.1 | xBbdIndex | 0 | 0 | The number of the rule. |
1.3.6.1.4.1.33.24.7.2.1.1.2 | xBbdName | 0 | 0 | The name of the rule. |
1.3.6.1.4.1.33.24.7.2.1.1.3 | xBbdAdminState | 0 | 0 | Controls whether this Bbd rule is enabled or disabled. |
1.3.6.1.4.1.33.24.7.2.1.1.4 | xBbdPrimaryAddress | 0 | 0 | The address of the unit whose circuit/link should be monitored. 00-00-00-00-00-00 is this unit. |
1.3.6.1.4.1.33.24.7.2.1.1.5 | xBbdPrimaryIfType | 0 | 0 | xBbdPrimaryIftype |
1.3.6.1.4.1.33.24.7.2.1.1.6 | xBbdPrimaryIf | 0 | 0 | The circuit or link being monitored. 0 indicates nothing is being monitored by this rule. |
1.3.6.1.4.1.33.24.7.2.1.1.7 | xBbdPrimaryName | 0 | 0 | The name of the primary circuit/link. |
1.3.6.1.4.1.33.24.7.2.1.1.8 | xBbdPrimaryPollTimer | 0 | 0 | The number of seconds to wait before polling the primary circuit/link again. |
1.3.6.1.4.1.33.24.7.2.1.1.9 | xBbdFailureBackup | 0 | 0 | Controls whether the primary circuit/link will be backed up if the primary circuit/link fails. |
1.3.6.1.4.1.33.24.7.2.1.1.10 | xBbdUpUtilization | 0 | 0 | The high threshold utilization of the primary circuit/link which must be exceeded for this rule to try to bring up a(nother) back… |
1.3.6.1.4.1.33.24.7.2.1.1.11 | xBbdDownUtilization | 0 | 0 | The low threshold utilization of the primary circuit/link which must be exceeded for this rule to try to bring down a(nother) bac… |
1.3.6.1.4.1.33.24.7.2.1.1.12 | xBbdDampeningFactor | 0 | 0 | The number of polling measurements to average when calculating the primary circuit/link's utilization. |
1.3.6.1.4.1.33.24.7.2.1.1.13 | xBbdUpHoldTimer | 0 | 0 | The number of seconds after a backup circuit has been brought up before the primary link should be polled again. |
1.3.6.1.4.1.33.24.7.2.1.1.14 | xBbdDownHoldTimer | 0 | 0 | The number of seconds after a backup circuit has been brought down before the primary link should be polled again. |
1.3.6.1.4.1.33.24.7.2.1.1.15 | xBbdPriority | 0 | 0 | The priority associated with the rule. |
1.3.6.1.4.1.33.24.7.2.1.1.16 | xBbdMaxActiveChoices | 0 | 0 | The maximum number of circuits that can be brought up by the rule. |
1.3.6.1.4.1.33.24.7.2.1.1.17 | xBbdDisableDelay | 0 | 0 | The number of seconds the primary circuit/link must not exceed the down utilization before a backup circuit will be brought down. |
1.3.6.1.4.1.33.24.7.2.1.1.18 | xBbdEnableDelay | 0 | 0 | The number of seconds the primary circuit/link must exceed the up utilization before a backup circuit will be brought up. |
1.3.6.1.4.1.33.24.7.2.1.1.19 | xBbdEventLogging | 0 | 0 | Controls whether events will be logged for this Bbd rule. |
1.3.6.1.4.1.33.24.7.2.1.1.20 | xBbdSecondaryAddress | 0 | 0 | The address of the secondary unit whose circuit/link should be monitored. 00-00-00-00-00-00 is this unit. |
1.3.6.1.4.1.33.24.7.2.1.1.21 | xBbdSecondaryIfType | 0 | 0 | xBbdSecondaryIftype |
1.3.6.1.4.1.33.24.7.2.1.1.22 | xBbdSecondaryIf | 0 | 0 | The secondary circuit or link being monitored. 0 indicates nothing is being monitored by this rule. |
1.3.6.1.4.1.33.24.7.2.1.1.23 | xBbdSecondaryName | 0 | 0 | The name of the secondary circuit/link. |
1.3.6.1.4.1.33.24.7.2.1.1.24 | xBbdSecondaryDownUtil | 0 | 0 | The low threshold utilization of the secondary circuit/link which must be exceeded for this rule to try to bring down a(nother) b… |
1.3.6.1.4.1.33.24.7.2.1.1.25 | xBbdRowStatus | 0 | 0 | Setting this object to active(1) activates the rule. This is equivalent to creating the rule. Setting this object to notInService… |
1.3.6.1.4.1.33.24.7.2.1.1.26 | xBbdUtilizationToUse | 0 | 0 | This objects controls which utilization is used on a primary circuit to control the activation and deactivation of the backup cir… |
1.3.6.1.4.1.33.24.7.2.1.1.27 | xBbdSecondaryUtilizationToUse | 0 | 0 | This objects controls which utilization is used on a secondary circuit to control the activation and deactivation of the backup c… |