This attribute contains the lowest reading supported
on
this fan's sensor, measured in the units specified
Fan Units attribute.
This attribute may not apply to
all fan types.
Parsed from file INTELCORPORATIONBASEBOARD-MIB.mib
Module: INTELCORPORATIONBASEBOARD-MIB
Vendor: Intel Corporation
Module: INTELCORPORATIONBASEBOARD-MIB
[Automatically extracted from oidview.com]
a1005MinimumReading OBJECT-TYPE SYNTAX DmiInteger ACCESS read-only STATUS mandatory DESCRIPTION "This attribute contains the lowest reading supported on this fan's sensor, measured in the units specified Fan Units attribute. This attribute may not apply to all fan types." ::= {eCoolingSensors 10}
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.343.2.10.3.4.1.1005.1.1 | a1005Selfid | 0 | 0 | A unique number that identifies this row. |
1.3.6.1.4.1.343.2.10.3.4.1.1005.1.2 | a1005FruGroupIndex | 0 | 0 | If this is a Field Replaceable Unit or if it is part of another FRU, thisprovides an index into the FRU table; 'value = -1' indi… |
1.3.6.1.4.1.343.2.10.3.4.1.1005.1.3 | a1005OperationalGroupIndex | 0 | 0 | The index into the Operational State table for this device. |
1.3.6.1.4.1.343.2.10.3.4.1.1005.1.6 | a1005CoolingDeviceType | 0 | 0 | This attribute describes the fan type. It has one of the following values: Muffin, Axial, Piezo, or Squirrel Cage. |
1.3.6.1.4.1.343.2.10.3.4.1.1005.1.7 | a1005CfmRating | 0 | 0 | This attribute presents the maximum CFM rating of this fan. |
1.3.6.1.4.1.343.2.10.3.4.1.1005.1.8 | a1005FanUnits | 0 | 0 | This attribute describes the units of fan status measurement. It has one of the following values: RPM, CFM, or OK/Fatal. |
1.3.6.1.4.1.343.2.10.3.4.1.1005.1.9 | a1005MaximumReading | 0 | 0 | This attribute contains the highest reading supported on this fan's sensor, measured in the units specified by the Fan Units attri… |
1.3.6.1.4.1.343.2.10.3.4.1.1005.1.11 | a1005CurrentReading | 0 | 0 | This attribute contains the current fan sensor reading, measured in the units specified by the Fan Units attribute. This attribut… |
1.3.6.1.4.1.343.2.10.3.4.1.1005.1.13 | a1005SensorAccuracy | 0 | 0 | This attribute describes the sensor's accuracy in +/- hundredth of a percent. |
1.3.6.1.4.1.343.2.10.3.4.1.1005.1.14 | a1005SensorTolerancePlus | 0 | 0 | This attribute describes the sensor's '+' tolerance in the units specified by the Fan Units attribute. |
1.3.6.1.4.1.343.2.10.3.4.1.1005.1.15 | a1005SensorToleranceMinus | 0 | 0 | This attribute describes the sensor's '-' tolerance in the units specified by the Fan Units attribute. |
1.3.6.1.4.1.343.2.10.3.4.1.1005.1.16 | a1005Non-criticalThreshold | 0 | 0 | This attribute contains the warning threshold level for the fan. The threshold is given in the units specified by the Fan Units at… |
1.3.6.1.4.1.343.2.10.3.4.1.1005.1.17 | a1005CriticalThreshold | 0 | 0 | This attribute contains the major error threshold level for the fan. The threshold is given in the units specified by the Fan Uni… |
1.3.6.1.4.1.343.2.10.3.4.1.1005.1.18 | a1005Non-recoverableThreshold | 0 | 0 | This attribute contains the fatal error threshold level for the fan. The threshold is given in the units specified by the Fan Uni… |
1.3.6.1.4.1.343.2.10.3.4.1.1005.1.19 | a1005CoolingSensorDescription | 0 | 0 | Additional descriptive information about the Cooling sensor orsensor's location. |
1.3.6.1.4.1.343.2.10.3.4.1.1005.1.21 | a1005NominalReading | 0 | 0 | Nominal reading for this fan, in units. 80000000h indicates that this attribute is not supported. |
1.3.6.1.4.1.343.2.10.3.4.1.1005.1.22 | a1005LowestNormalReading | 0 | 0 | Specified lowest normal reading for this fan, in units. Readings beyond this value indicate an abnormal condition. 80000000h indica… |
1.3.6.1.4.1.343.2.10.3.4.1.1005.1.23 | a1005HighestNormalReading | 0 | 0 | Specified lowest normal reading for this fan, in units. Readings beyond this value indicate an abnormal condition. 80000000h indica… |