This attribute describes the fan type. It has one
of the
following values: Muffin, Axial, Piezo, or
Squirrel Cage.
Parsed from file INTELCORPORATIONBASEBOARD-MIB.mib
Module: INTELCORPORATIONBASEBOARD-MIB
Vendor: Intel Corporation
Module: INTELCORPORATIONBASEBOARD-MIB
[Automatically extracted from oidview.com]
a1005CoolingDeviceType OBJECT-TYPE SYNTAX INTEGER { vOther (1), vUnknown (2), vFan (3), vCentrifugalBlower (4), vChipFan (5), vCabinetFan (6), vPowerSupplyFan (7), vHeatPipe (8), vIntegratedRefrigeration (9), vActiveCooling (32), vPassiveCooling (33) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute describes the fan type. It has one of the following values: Muffin, Axial, Piezo, or Squirrel Cage." ::= {eCoolingSensors 6}
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.343.2.10.3.4.1.1005.1.1 | a1005Selfid | 0 | 0 | A unique number that identifies this row. |
1.3.6.1.4.1.343.2.10.3.4.1.1005.1.2 | a1005FruGroupIndex | 0 | 0 | If this is a Field Replaceable Unit or if it is part of another FRU, thisprovides an index into the FRU table; 'value = -1' indi… |
1.3.6.1.4.1.343.2.10.3.4.1.1005.1.3 | a1005OperationalGroupIndex | 0 | 0 | The index into the Operational State table for this device. |
1.3.6.1.4.1.343.2.10.3.4.1.1005.1.7 | a1005CfmRating | 0 | 0 | This attribute presents the maximum CFM rating of this fan. |
1.3.6.1.4.1.343.2.10.3.4.1.1005.1.8 | a1005FanUnits | 0 | 0 | This attribute describes the units of fan status measurement. It has one of the following values: RPM, CFM, or OK/Fatal. |
1.3.6.1.4.1.343.2.10.3.4.1.1005.1.9 | a1005MaximumReading | 0 | 0 | This attribute contains the highest reading supported on this fan's sensor, measured in the units specified by the Fan Units attri… |
1.3.6.1.4.1.343.2.10.3.4.1.1005.1.10 | a1005MinimumReading | 0 | 0 | This attribute contains the lowest reading supported on this fan's sensor, measured in the units specified Fan Units attribute. Thi… |
1.3.6.1.4.1.343.2.10.3.4.1.1005.1.11 | a1005CurrentReading | 0 | 0 | This attribute contains the current fan sensor reading, measured in the units specified by the Fan Units attribute. This attribut… |
1.3.6.1.4.1.343.2.10.3.4.1.1005.1.13 | a1005SensorAccuracy | 0 | 0 | This attribute describes the sensor's accuracy in +/- hundredth of a percent. |
1.3.6.1.4.1.343.2.10.3.4.1.1005.1.14 | a1005SensorTolerancePlus | 0 | 0 | This attribute describes the sensor's '+' tolerance in the units specified by the Fan Units attribute. |
1.3.6.1.4.1.343.2.10.3.4.1.1005.1.15 | a1005SensorToleranceMinus | 0 | 0 | This attribute describes the sensor's '-' tolerance in the units specified by the Fan Units attribute. |
1.3.6.1.4.1.343.2.10.3.4.1.1005.1.16 | a1005Non-criticalThreshold | 0 | 0 | This attribute contains the warning threshold level for the fan. The threshold is given in the units specified by the Fan Units at… |
1.3.6.1.4.1.343.2.10.3.4.1.1005.1.17 | a1005CriticalThreshold | 0 | 0 | This attribute contains the major error threshold level for the fan. The threshold is given in the units specified by the Fan Uni… |
1.3.6.1.4.1.343.2.10.3.4.1.1005.1.18 | a1005Non-recoverableThreshold | 0 | 0 | This attribute contains the fatal error threshold level for the fan. The threshold is given in the units specified by the Fan Uni… |
1.3.6.1.4.1.343.2.10.3.4.1.1005.1.19 | a1005CoolingSensorDescription | 0 | 0 | Additional descriptive information about the Cooling sensor orsensor's location. |
1.3.6.1.4.1.343.2.10.3.4.1.1005.1.21 | a1005NominalReading | 0 | 0 | Nominal reading for this fan, in units. 80000000h indicates that this attribute is not supported. |
1.3.6.1.4.1.343.2.10.3.4.1.1005.1.22 | a1005LowestNormalReading | 0 | 0 | Specified lowest normal reading for this fan, in units. Readings beyond this value indicate an abnormal condition. 80000000h indica… |
1.3.6.1.4.1.343.2.10.3.4.1.1005.1.23 | a1005HighestNormalReading | 0 | 0 | Specified lowest normal reading for this fan, in units. Readings beyond this value indicate an abnormal condition. 80000000h indica… |