This object is used to enable or disable the K1/K2 inband
interface on the protection line.
Parsed from file CISCO-MGX82XX-SONET-MIB.mib
Module: CISCO-MGX82XX-SONET-MIB
Vendor: Stratacom
Module: CISCO-MGX82XX-SONET-MIB
[Automatically extracted from oidview.com]
apsK1K2Disable OBJECT-TYPE SYNTAX INTEGER { kbandEnable (1), kbandDisable (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This object is used to enable or disable the K1/K2 inband interface on the protection line. " ::= { sonetApsConfigEntry 13 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.351.110.4.6.1.6.1.1.1 | apsWorkingSlot | 0 | 0 | This object is the chassis slot number of the working line MGX 8x50 PXM: can only be slot 7 or 8. MGX 8x30 PXM: can only be slot … |
1.3.6.1.4.1.351.110.4.6.1.6.1.1.2 | apsWorkingLine | 0 | 0 | This object is the line number of the working line OC-3 : sonetLineNum in a range 1..4 OC-12: sonetLineNum = 1 is the ONLY valid … |
1.3.6.1.4.1.351.110.4.6.1.6.1.1.3 | apsProtectionSlot | 0 | 0 | This object is the chassis slot number of the protection line MGX 8x50 PXM: can only be slot 7 or 8. MGX 8x30 PXM: can only be sl… |
1.3.6.1.4.1.351.110.4.6.1.6.1.1.4 | apsProtectionLine | 0 | 0 | This object is the line number of the working line OC-3 : sonetLineNum in a range 1..4 OC-12: sonetLineNum = 1 is the ONLY valid … |
1.3.6.1.4.1.351.110.4.6.1.6.1.1.5 | apsEnable | 0 | 0 | This object is used to enable or disable APS feature on the working/protection line pairs. |
1.3.6.1.4.1.351.110.4.6.1.6.1.1.6 | apsArchMode | 0 | 0 | This object is used to configure APS architecture mode on the working/protection line pairs. The architecture modes currently sup… |
1.3.6.1.4.1.351.110.4.6.1.6.1.1.7 | apsActiveLine | 0 | 0 | This object indicates which line is currently active ob the trunk line. |
1.3.6.1.4.1.351.110.4.6.1.6.1.1.8 | apsSFBER | 0 | 0 | This object contains the Bit Error Rate threshold for Signal Fault detection on the working line. |
1.3.6.1.4.1.351.110.4.6.1.6.1.1.9 | apsSDBER | 0 | 0 | This object contains the Bit Error Rate threshold for Signal Degrade detection on the working line. If set to 5, it means SDBER r… |
1.3.6.1.4.1.351.110.4.6.1.6.1.1.10 | apsWtr | 0 | 0 | This object contains interval (in minute) to wait before attempting to switch back to working line. Not applicable if the line co… |
1.3.6.1.4.1.351.110.4.6.1.6.1.1.11 | apsdirection | 0 | 0 | This object is used to configure the switching direction which this APS line support. Unidirectional switch only one direction. B… |
1.3.6.1.4.1.351.110.4.6.1.6.1.1.12 | apsRevertive | 0 | 0 | This object is used to configure the APS revertive or nonrevertive option. Revertive allows the line to be switch back to workin… |