This is a logical port number. If PXM1
(Processor Switch Module) is the PXM
used on the shelf this object should be set to 1.
For PXM1E this object should be set to 255.
Parsed from file CISCO-VISM-PORT-MIB.mib
Module: CISCO-VISM-PORT-MIB
This is a logical port number. If PXM1
(Processor Switch Module) is the PXM
used on the shelf this object should be set to 1.
For PXM1E this object should be set to 255.
This is a logical port number. If PXM1
(Processor Switch Module) is the PXM
used on the shelf this object should be set to 1.
For PXM1E this object should be set to 255.
Parsed from file CISCO-VISM-PORT-MIB.my.txt
Company: None
Module: CISCO-VISM-PORT-MIB
This is a logical port number. If PXM1
(Processor Switch Module) is the PXM
used on the shelf this object should be set to 1.
For PXM1E this object should be set to 255.
vismPortNum OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a logical port number. If PXM1 (Processor Switch Module) is the PXM used on the shelf this object should be set to 1. For PXM1E this object should be set to 255. " ::= { vismPortCnfGrpEntry 1}
vismPortNum OBJECT-TYPE SYNTAX INTEGER(0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "This is a logical port number. If PXM1 (Processor Switch Module) is the PXM used on the shelf this object should be set to 1. For PXM1E this object should be set to 255. " ::= { vismPortCnfGrpEntry 1 }
Vendor: Stratacom
Module: CISCO-WAN-AXIPOP-MIB
[Automatically extracted from oidview.com]
vismPortNum OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a logical port number. If PXM1 (Processor Switch Module) is the PXM used on the shelf this object should be set to 1. For PXM1E this object should be set to 255. " ::= { vismPortCnfGrpEntry 1}
vismPortNum OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This is a logical port number. If PXM1 (Processor Switch Module) is the PXM used on the shelf this object should be set to 1. For PXM1E this object should be set to 255. " ::= { vismPortCnfGrpEntry 1}
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.351.110.5.5.2.1.1.1.2 | vismPortRowStatus | 0 | 0 | The object add, delete or modify a port. 'add' - add a port, a port acn only be added if the status is in 'del'. 'del' - delete a… |
1.3.6.1.4.1.351.110.5.5.2.1.1.1.3 | vismPortLineNum | 0 | 0 | This represents the line number to which this port is associated. Since the network port is not associated with any line, line nu… |
1.3.6.1.4.1.351.110.5.5.2.1.1.1.4 | vismPortType | 0 | 0 | The value of this object is always set to 'voIP'. It indicates that network port. The same value is used even when VISM supports … |
1.3.6.1.4.1.351.110.5.5.2.1.1.1.5 | vismPortDs0ConfigBitMap | 0 | 0 | This respesents the bit map of DS0s which is used to create this port. Bit 0 represents DS0-1. Since this object is not applicab… |
1.3.6.1.4.1.351.110.5.5.2.1.1.1.6 | vismPortSpeed | 0 | 0 | The speed of the port in cells per second. It is used by VISM card to advertise virtual port bandwidth to the controller, SVC(Swi… |
1.3.6.1.4.1.351.110.5.5.2.1.1.1.7 | vismPortState | 0 | 0 | This object indicates the state of the port. |