The state of this alarm entry.
Entries in the Alarm Table are marked as 'inactive' when the module
to which they refer:
- is removed or becomes 'asleep',
- returns an error in response to a poll request, or
- ignores a request message.
Inactive entries are still polled and are reactivated when:
- the module becomes 'awake', and
- whenever the module correctly returns a polled value.
Entries in the Alarm and Event Tables are deleted either by a
network manager, or whenever a stack or hub reconfiguration occurs
such that a module of a different type now occupies the slot being
polled. (Modules are determined to be 'of a different type' when
their sysObjectIDs differ.)
Parsed from file hubmg3-0.mib.txt
Company: None
Module: DECHUB900-HUBMGR-MIB-V3-0
The state of this alarm entry.
Entries in the Alarm Table are marked as 'inactive' when the module
to which they refer:
- is removed or becomes 'asleep',
- returns an error in response to a poll request, or
- ignores a request message.
Inactive entries are still polled and are reactivated when:
- the module becomes 'awake', and
- whenever the module correctly returns a polled value.
Entries in the Alarm and Event Tables are deleted either by a
network manager, or whenever a stack or hub reconfiguration occurs
such that a module of a different type now occupies the slot being
polled. (Modules are determined to be 'of a different type' when
their sysObjectIDs differ.)
Parsed from file DECHUB900-HUBMGR-MIB-V3-0.mib
Module: DECHUB900-HUBMGR-MIB-V3-0
Vendor: DEC
Module: DECHUB900-HUBMGR-MIB-V3-0
[Automatically extracted from oidview.com]
hubAlarmState OBJECT-TYPE SYNTAX INTEGER { active(1), inactive(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of this alarm entry. Entries in the Alarm Table are marked as 'inactive' when the module to which they refer: - is removed or becomes 'asleep', - returns an error in response to a poll request, or - ignores a request message. Inactive entries are still polled and are reactivated when: - the module becomes 'awake', and - whenever the module correctly returns a polled value. Entries in the Alarm and Event Tables are deleted either by a network manager, or whenever a stack or hub reconfiguration occurs such that a module of a different type now occupies the slot being polled. (Modules are determined to be 'of a different type' when their sysObjectIDs differ.)" ::= { hubAlarmEntry 13 }
hubAlarmState OBJECT-TYPE SYNTAX INTEGER { active(1), inactive(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The state of this alarm entry. Entries in the Alarm Table are marked as 'inactive' when the module to which they refer: - is removed or becomes 'asleep', - returns an error in response to a poll request, or - ignores a request message. Inactive entries are still polled and are reactivated when: - the module becomes 'awake', and - whenever the module correctly returns a polled value. Entries in the Alarm and Event Tables are deleted either by a network manager, or whenever a stack or hub reconfiguration occurs such that a module of a different type now occupies the slot being polled. (Modules are determined to be 'of a different type' when their sysObjectIDs differ.)" ::= { hubAlarmEntry 13 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.1 | hubAlarmSlotNumber | 0 | 0 | The number of the slot in which the module to be monitored occupies in the hub chassis or the module's position in a stack. |
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.2 | hubAlarmIndex | 0 | 0 | An index that uniquely identifies an entry in the alarm table for a given slot. |
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.3 | hubAlarmInterval | 0 | 0 | The interval, in seconds, over which the data is sampled and compared with the rising and falling thresholds. This object may not… |
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.4 | hubAlarmVariable | 0 | 0 | The object identifier of the particular variable to be sampled. Only variables that resolve to an ASN.1 primitive type of INTEGE… |
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.5 | hubAlarmSampleType | 0 | 0 | The method of sampling the selected variable and calculating the value to be compared against the thresholds. If the value of t… |
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.6 | hubAlarmValue | 0 | 0 | The value of the statistic during the last sampling period. For example, if the sample type is deltaValue, this value is the dif… |
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.7 | hubAlarmStartupAlarm | 0 | 0 | The alarm that may be sent when this entry is first set to valid. If the first sample after this entry becomes valid is greater … |
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.8 | hubAlarmRisingThreshold | 0 | 0 | A threshold for the sampled statistic. When the current sampled value is greater than or equal to this threshold, and the value… |
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.9 | hubAlarmFallingThreshold | 0 | 0 | A threshold for the sampled statistic. When the current sampled value is less than or equal to this threshold, and the value at… |
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.10 | hubAlarmRisingEventIndex | 0 | 0 | The index of the eventEntry that is used when a rising threshold is crossed. The hubEventEntry identified by a particular value… |
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.11 | hubAlarmFallingEventIndex | 0 | 0 | The index of the hubEventEntry that is used when a falling threshold is crossed. The hubEventEntry identified by a particular v… |
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.12 | hubAlarmOwner | 0 | 0 | The entity that configured this entry and is therefore using the resources assigned to it. |
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.14 | hubAlarmStatus | 0 | 0 | The status of this alarm entry. (Refer to the RFC 1757 definition of 'EntryStatus.) |