A threshold for the sampled statistic. When the current sampled
value is less than or equal to this threshold, and the value at the
last sampling interval was greater than this threshold, a single
event will be generated. A single event will also be generated if
the first sample after this entry becomes valid is less than or
equal to this threshold and the associated hubAlarmStartupAlarm is
equal to fallingAlarm(2) or risingOrFallingAlarm(3).
After a falling event is generated, another such event will not be
generated until the sampled value rises above this threshold and
reaches the hubAlarmRisingThreshold.
This object may not be modified if the associated hubAlarmStatus
object is equal to valid(1).
Parsed from file hubmg3-0.mib.txt
Company: None
Module: DECHUB900-HUBMGR-MIB-V3-0
A threshold for the sampled statistic. When the current sampled
value is less than or equal to this threshold, and the value at the
last sampling interval was greater than this threshold, a single
event will be generated. A single event will also be generated if
the first sample after this entry becomes valid is less than or
equal to this threshold and the associated hubAlarmStartupAlarm is
equal to fallingAlarm(2) or risingOrFallingAlarm(3).
After a falling event is generated, another such event will not be
generated until the sampled value rises above this threshold and
reaches the hubAlarmRisingThreshold.
This object may not be modified if the associated hubAlarmStatus
object is equal to valid(1).
Parsed from file DECHUB900-HUBMGR-MIB-V3-0.mib
Module: DECHUB900-HUBMGR-MIB-V3-0
Vendor: DEC
Module: DECHUB900-HUBMGR-MIB-V3-0
[Automatically extracted from oidview.com]
hubAlarmFallingThreshold OBJECT-TYPE SYNTAX INTEGER (0..4294967295) ACCESS read-write STATUS mandatory DESCRIPTION "A threshold for the sampled statistic. When the current sampled value is less than or equal to this threshold, and the value at the last sampling interval was greater than this threshold, a single event will be generated. A single event will also be generated if the first sample after this entry becomes valid is less than or equal to this threshold and the associated hubAlarmStartupAlarm is equal to fallingAlarm(2) or risingOrFallingAlarm(3). After a falling event is generated, another such event will not be generated until the sampled value rises above this threshold and reaches the hubAlarmRisingThreshold. This object may not be modified if the associated hubAlarmStatus object is equal to valid(1)." ::= { hubAlarmEntry 9 }
hubAlarmFallingThreshold OBJECT-TYPE SYNTAX INTEGER (0..4294967295) ACCESS read-write STATUS mandatory DESCRIPTION "A threshold for the sampled statistic. When the current sampled value is less than or equal to this threshold, and the value at the last sampling interval was greater than this threshold, a single event will be generated. A single event will also be generated if the first sample after this entry becomes valid is less than or equal to this threshold and the associated hubAlarmStartupAlarm is equal to fallingAlarm(2) or risingOrFallingAlarm(3). After a falling event is generated, another such event will not be generated until the sampled value rises above this threshold and reaches the hubAlarmRisingThreshold. This object may not be modified if the associated hubAlarmStatus object is equal to valid(1)." ::= { hubAlarmEntry 9 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.1 | hubAlarmSlotNumber | 0 | 0 | The number of the slot in which the module to be monitored occupies in the hub chassis or the module's position in a stack. |
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.2 | hubAlarmIndex | 0 | 0 | An index that uniquely identifies an entry in the alarm table for a given slot. |
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.3 | hubAlarmInterval | 0 | 0 | The interval, in seconds, over which the data is sampled and compared with the rising and falling thresholds. This object may not… |
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.4 | hubAlarmVariable | 0 | 0 | The object identifier of the particular variable to be sampled. Only variables that resolve to an ASN.1 primitive type of INTEGE… |
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.5 | hubAlarmSampleType | 0 | 0 | The method of sampling the selected variable and calculating the value to be compared against the thresholds. If the value of t… |
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.6 | hubAlarmValue | 0 | 0 | The value of the statistic during the last sampling period. For example, if the sample type is deltaValue, this value is the dif… |
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.7 | hubAlarmStartupAlarm | 0 | 0 | The alarm that may be sent when this entry is first set to valid. If the first sample after this entry becomes valid is greater … |
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.8 | hubAlarmRisingThreshold | 0 | 0 | A threshold for the sampled statistic. When the current sampled value is greater than or equal to this threshold, and the value… |
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.10 | hubAlarmRisingEventIndex | 0 | 0 | The index of the eventEntry that is used when a rising threshold is crossed. The hubEventEntry identified by a particular value… |
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.11 | hubAlarmFallingEventIndex | 0 | 0 | The index of the hubEventEntry that is used when a falling threshold is crossed. The hubEventEntry identified by a particular v… |
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.12 | hubAlarmOwner | 0 | 0 | The entity that configured this entry and is therefore using the resources assigned to it. |
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.13 | hubAlarmState | 0 | 0 | The state of this alarm entry. Entries in the Alarm Table are marked as 'inactive' when the module to which they refer: - is remov… |
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.14 | hubAlarmStatus | 0 | 0 | The status of this alarm entry. (Refer to the RFC 1757 definition of 'EntryStatus.) |