Software configuration variable set by network management.
Auto Wrap Enabled (AWE) should be set on(1) for connection to
end stations and the RingIn ports of DEC token ring products.
It may be set off(2) for lobe connection to IBM 8228 or
equivalent 'dumb' linecards which do not drive phantom current.
The factory default is on(1).
The value of this object is maintained across power cycles
and resets.
Parsed from file DEChub900-TokenRing.mib.txt
Company: None
Module: DECHUB900-PTRM-MIB-V3-0
Software configuration variable set by network management.
Auto Wrap Enabled (AWE) should be set on(1) for connection to
end stations and the RingIn ports of DEC token ring products.
It may be set off(2) for lobe connection to IBM 8228 or
equivalent 'dumb' linecards which do not drive phantom current.
The factory default is on(1).
The value of this object is maintained across power cycles
and resets.
Parsed from file DECHUB900-PTRM-MIB-V3-0.mib
Module: DECHUB900-PTRM-MIB-V3-0
Vendor: DEC
Module: DECHUB900-PTRM-MIB-V3-0
[Automatically extracted from oidview.com]
ptrmLobeAutoWrapEnable OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Software configuration variable set by network management. Auto Wrap Enabled (AWE) should be set on(1) for connection to end stations and the RingIn ports of DEC token ring products. It may be set off(2) for lobe connection to IBM 8228 or equivalent 'dumb' linecards which do not drive phantom current. The factory default is on(1). The value of this object is maintained across power cycles and resets." ::= { ptrmLobeEntry 5 }
ptrmLobeAutoWrapEnable OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Software configuration variable set by network management. Auto Wrap Enabled (AWE) should be set on(1) for connection to end stations and the RingIn ports of DEC token ring products. It may be set off(2) for lobe connection to IBM 8228 or equivalent 'dumb' linecards which do not drive phantom current. The factory default is on(1). The value of this object is maintained across power cycles and resets." ::= { ptrmLobeEntry 5 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.36.2.18.11.3.3.1.1 | ptrmLobeIndex | 0 | 0 | Port number for the lobe, as it appears externally to the user, i.e. 1 for the port labeled '1'. |
1.3.6.1.4.1.36.2.18.11.3.3.1.2 | ptrmLobeOperStatus | 0 | 0 | Indicates whether the lobe port is wrapped or inserted into the linecard's internal ring. If the lobe port is not implemented in… |
1.3.6.1.4.1.36.2.18.11.3.3.1.3 | ptrmLobeAdminStatus | 0 | 0 | Used to disable the lobe port during network troubleshooting. If set to disabled(2), the lobe port is forced to wrap. This object… |
1.3.6.1.4.1.36.2.18.11.3.3.1.4 | ptrmLobeMedia | 0 | 0 | The media type of the lobe port. Different module types have different lobe connectors. If a module implements an STP/UTP switc… |
1.3.6.1.4.1.36.2.18.11.3.3.1.6 | ptrmLobeAutoPartitionStatus | 0 | 0 | Indicates whether the lobe port has been auto-partitioned. When autoPartitioned(2), a lobe is automatically wrapped. |
1.3.6.1.4.1.36.2.18.11.3.3.1.7 | ptrmLobeDetectedSpeed | 0 | 0 | Indicates the speed detected on the incoming data pair. If invalid(1) a valid token ring speed was not detected. If notApplicable… |
1.3.6.1.4.1.36.2.18.11.3.3.1.8 | ptrmLobePhantomDrive | 0 | 0 | This variable is not applicable to lobe ports, and is defined only as a place holder for the corresponding trunk variable. |
1.3.6.1.4.1.36.2.18.11.3.3.1.9 | ptrmLobePhantomDetect | 0 | 0 | Indicates the state of the incoming phantom current detect circuit for the lobe port. Lobe ports are required to implement phant… |