Reference record for OID 1.3.6.1.4.1.412.2.4.52.1


parent
1.3.6.1.4.1.412.2.4.52 (dmtfUPSBatteryTable)
node code
1
node name
dmtfUPSBatteryEntry
dot oid
1.3.6.1.4.1.412.2.4.52.1
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dmtf(412) dmtfStdMifs(2) dmtfSystemsMIF(4) dmtfUPSBatteryTable(52) dmtfUPSBatteryEntry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dmtf(412) dmtfStdMifs(2) mapperdmtfGroups(4) dmtfUPSBatteryTable(52) dmtfUPSBatteryEntry(1)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) dmtf(412) dmtfStdMifs(2) dmtfSystemsMIF(4) dmtfUPSBatteryTable(52) dmtfUPSBatteryEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) dmtf(412) dmtfStdMifs(2) mapperdmtfGroups(4) dmtfUPSBatteryTable(52) dmtfUPSBatteryEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) dmtf(412) dmtfStdMifs(2) dmtfSystemsMIF(4) dmtfUPSBatteryTable(52) dmtfUPSBatteryEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) dmtf(412) dmtfStdMifs(2) mapperdmtfGroups(4) dmtfUPSBatteryTable(52) dmtfUPSBatteryEntry(1)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) dmtf(412) dmtfStdMifs(2) dmtfSystemsMIF(4) dmtfUPSBatteryTable(52) dmtfUPSBatteryEntry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) dmtf(412) dmtfStdMifs(2) mapperdmtfGroups(4) dmtfUPSBatteryTable(52) dmtfUPSBatteryEntry(1)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/dmtf/dmtfStdMifs/dmtfSystemsMIF/dmtfUPSBatteryTable/dmtfUPSBatteryEntry
  • /iso/identified-organization/dod/internet/private/enterprise/dmtf/dmtfStdMifs/mapperdmtfGroups/dmtfUPSBatteryTable/dmtfUPSBatteryEntry
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/dmtf/dmtfStdMifs/dmtfSystemsMIF/dmtfUPSBatteryTable/dmtfUPSBatteryEntry
  • /iso/org/dod/internet/private/enterprise/dmtf/dmtfStdMifs/mapperdmtfGroups/dmtfUPSBatteryTable/dmtfUPSBatteryEntry
  • /iso/org/dod/internet/private/enterprises/dmtf/dmtfStdMifs/dmtfSystemsMIF/dmtfUPSBatteryTable/dmtfUPSBatteryEntry
  • /iso/org/dod/internet/private/enterprises/dmtf/dmtfStdMifs/mapperdmtfGroups/dmtfUPSBatteryTable/dmtfUPSBatteryEntry
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/dmtf/dmtfStdMifs/dmtfSystemsMIF/dmtfUPSBatteryTable/dmtfUPSBatteryEntry
  • /iso/iso-identified-organization/dod/internet/private/enterprises/dmtf/dmtfStdMifs/mapperdmtfGroups/dmtfUPSBatteryTable/dmtfUPSBatteryEntry
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/412/2/4/52/1

    Description by mibdepot

    The UPS Battery group contains information regarding the
    UPS system's battery status.

    Parsed from file dmtf-systems.mib.txt
    Company: None
    Module: DMTF-SYSTEMS-MIB

    Description by circitor

    The UPS Battery group contains information regarding the
    UPS system's battery status.

    Parsed from file DMTF-SYSTEMS-MIB.mib
    Module: DMTF-SYSTEMS-MIB

    Information by oid_info

    Vendor: Distributed Management Task Force (DMTF)
    Module: DMTF-SYSTEMS-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    dmtfUPSBatteryEntry OBJECT-TYPE SYNTAX SdmtfUPSBattery MAX-ACCESS not-accessible STATUS current DESCRIPTION "The UPS Battery group contains information regarding the UPS system's battery status." INDEX { DmiCompId,DmiGroupId } ::= { dmtfUPSBatteryTable 1 }

    Information by circitor

    dmtfUPSBatteryEntry OBJECT-TYPE SYNTAX SdmtfUPSBattery MAX-ACCESS not-accessible STATUS current DESCRIPTION "The UPS Battery group contains information regarding the UPS system's battery status." INDEX { DmiCompId,DmiGroupId } ::= { dmtfUPSBatteryTable 1 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.412)

    Williams Raymond C.

    Children (9)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.412.2.4.52.1.1 batteryStatus 0 0 The indication of the capacity remaining in the UPS system's
    batteries. A value of 'battery normal' indicates that the remainin…
    1.3.6.1.4.1.412.2.4.52.1.2 secondsOnBattery 0 0 If the UPS is on battery power, the elapsed time in seconds
    since the UPS last switched to battery power, or the time since the …
    1.3.6.1.4.1.412.2.4.52.1.3 estimatedMinutesRemaining 0 0 An estimate in minutes of the time to battery charge depletion
    under the present load conditions if the utility power is off and…
    1.3.6.1.4.1.412.2.4.52.1.4 estimatedChargeRemaining 0 0 An estimate of the time to battery charge depletion under
    the present load conditions if the utility power is off and remains of…
    1.3.6.1.4.1.412.2.4.52.1.5 batteryVoltage 0 0 The magnitude of the present battery voltage in 0.1 volts
    DC.
    1.3.6.1.4.1.412.2.4.52.1.6 batteryCurrent 0 0 The present battery current in 0.1 Amps DC.
    1.3.6.1.4.1.412.2.4.52.1.7 temperatureProbeIndex 0 0 None
    1.3.6.1.4.1.412.2.4.52.1.8 fRUGroupIndex 0 0 None
    1.3.6.1.4.1.412.2.4.52.1.9 operationalGroupIndex 0 0 None

    Brothers (3)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.412.2.4.52.0 dmtfUPSBatteryTraps 3 3 None
    1.3.6.1.4.1.412.2.4.52.6 dmtfUPSBatteryEvSys 1 1 The major functional aspect of the product causing the fault.
    1.3.6.1.4.1.412.2.4.52.7 dmtfUPSBatteryEvSub 1 1 The minor functional aspect of the product causing the fault.