The indication of the capacity remaining in the UPS system's
batteries. A value of 'battery normal' indicates that the remaining estimated
minutes of run-time is greater than the UPS's configured 'low battery time'
(typically two minutes). A value of 'battery low' indicates that the remaining
estimated minutes of battery run-time is less than or equal to the UPS's
configured 'low battery time'. A value of 'battery depleted' indicates that
the UPS will be unable to sustain the present load when and if
Parsed from file dmtf-systems.mib.txt
Company: None
Module: DMTF-SYSTEMS-MIB
The indication of the capacity remaining in the UPS system's
batteries. A value of 'battery normal' indicates that the remaining estimated
minutes of run-time is greater than the UPS's configured 'low battery time'
(typically two minutes). A value of 'battery low' indicates that the remaining
estimated minutes of battery run-time is less than or equal to the UPS's
configured 'low battery time'. A value of 'battery depleted' indicates that
the UPS will be unable to sustain the present load when and if
Parsed from file DMTF-SYSTEMS-MIB.mib
Module: DMTF-SYSTEMS-MIB
Vendor: Distributed Management Task Force (DMTF)
Module: DMTF-SYSTEMS-MIB
[Automatically extracted from oidview.com]
batteryStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), batteryNormal(2), batteryLow(3), batteryDepleted(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The indication of the capacity remaining in the UPS system's batteries. A value of 'battery normal' indicates that the remaining estimated minutes of run-time is greater than the UPS's configured 'low battery time' (typically two minutes). A value of 'battery low' indicates that the remaining estimated minutes of battery run-time is less than or equal to the UPS's configured 'low battery time'. A value of 'battery depleted' indicates that the UPS will be unable to sustain the present load when and if " REFERENCE "'DMTF|UPS Battery|001' 1" ::= { dmtfUPSBatteryEntry 1 }
batteryStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), batteryNormal(2), batteryLow(3), batteryDepleted(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The indication of the capacity remaining in the UPS system's batteries. A value of 'battery normal' indicates that the remaining estimated minutes of run-time is greater than the UPS's configured 'low battery time' (typically two minutes). A value of 'battery low' indicates that the remaining estimated minutes of battery run-time is less than or equal to the UPS's configured 'low battery time'. A value of 'battery depleted' indicates that the UPS will be unable to sustain the present load when and if " REFERENCE "'DMTF|UPS Battery|001' 1" ::= { dmtfUPSBatteryEntry 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.412.2.4.52.1.2 | secondsOnBattery | 0 | 0 | If the UPS is on battery power, the elapsed time in seconds since the UPS last switched to battery power, or the time since the … |
1.3.6.1.4.1.412.2.4.52.1.3 | estimatedMinutesRemaining | 0 | 0 | An estimate in minutes of the time to battery charge depletion under the present load conditions if the utility power is off and… |
1.3.6.1.4.1.412.2.4.52.1.4 | estimatedChargeRemaining | 0 | 0 | An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains of… |
1.3.6.1.4.1.412.2.4.52.1.5 | batteryVoltage | 0 | 0 | The magnitude of the present battery voltage in 0.1 volts DC. |
1.3.6.1.4.1.412.2.4.52.1.6 | batteryCurrent | 0 | 0 | The present battery current in 0.1 Amps DC. |
1.3.6.1.4.1.412.2.4.52.1.7 | temperatureProbeIndex | 0 | 0 | None |
1.3.6.1.4.1.412.2.4.52.1.8 | fRUGroupIndex | 0 | 0 | None |
1.3.6.1.4.1.412.2.4.52.1.9 | operationalGroupIndex | 0 | 0 | None |