This defines how often, in seconds, a poll packet is sent to
the device being polled.
If burst mode(0) is chosen, then number of packets selected will
be sent out as fast as possible when the a3ComPollAction is set to
activate(2).
Common values the a3ComPollRate can be set to:
every 3 seconds (3) default every minute (60)
every 5 minutes (300) every 15 minutes (900)
every 30 minutes (1800) every hour (3600)
This object may not be modified if the associated a3ComPollReport
is equal to busy(2). When this object is successfully set,
a3ComPollReport will be set to idle(1).
Parsed from file 3cPoll.mib.txt
Company: None
Module: A3COM-SWITCHING-SYSTEMS-POLL-MIB
This defines how often, in seconds, a poll packet is sent to
the device being polled.
If burst mode(0) is chosen, then number of packets selected will
be sent out as fast as possible when the a3ComPollAction is set to
activate(2).
Common values the a3ComPollRate can be set to:
every 3 seconds (3) default every minute (60)
every 5 minutes (300) every 15 minutes (900)
every 30 minutes (1800) every hour (3600)
This object may not be modified if the associated a3ComPollReport
is equal to busy(2). When this object is successfully set,
a3ComPollReport will be set to idle(1).
Parsed from file A3COM-SWITCHING-SYSTEMS-POLL-MIB.mib
Module: A3COM-SWITCHING-SYSTEMS-POLL-MIB
Vendor: 3Com
Module: A3COM-SWITCHING-SYSTEMS-POLL-MIB
[Automatically extracted from oidview.com]
a3ComPollRate OBJECT-TYPE SYNTAX INTEGER (0..5400) ACCESS read-write STATUS mandatory DESCRIPTION "This defines how often, in seconds, a poll packet is sent to the device being polled. If burst mode(0) is chosen, then number of packets selected will be sent out as fast as possible when the a3ComPollAction is set to activate(2). Common values the a3ComPollRate can be set to: every 3 seconds (3) default every minute (60) every 5 minutes (300) every 15 minutes (900) every 30 minutes (1800) every hour (3600) This object may not be modified if the associated a3ComPollReport is equal to busy(2). When this object is successfully set, a3ComPollReport will be set to idle(1)." DEFVAL { 3 } ::= { a3ComPollEntry 6 }
a3ComPollRate OBJECT-TYPE SYNTAX INTEGER (0..5400) ACCESS read-write STATUS mandatory DESCRIPTION "This defines how often, in seconds, a poll packet is sent to the device being polled. If burst mode(0) is chosen, then number of packets selected will be sent out as fast as possible when the a3ComPollAction is set to activate(2). Common values the a3ComPollRate can be set to: every 3 seconds (3) default every minute (60) every 5 minutes (300) every 15 minutes (900) every 30 minutes (1800) every hour (3600) This object may not be modified if the associated a3ComPollReport is equal to busy(2). When this object is successfully set, a3ComPollReport will be set to idle(1)." DEFVAL { 3 } ::= { a3ComPollEntry 6 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.43.29.4.22.1.1.1 | a3ComPollIndex | 0 | 0 | Unique identifier of a row in the Poll Table. The actual number of rows that can be created on any particular device depends on t… |
1.3.6.1.4.1.43.29.4.22.1.1.2 | a3ComPollAddress | 0 | 0 | This DisplayString is the network address of the device to monitor. Typically this is an IP, dotted IP format, IP's hostname, IPX… |
1.3.6.1.4.1.43.29.4.22.1.1.3 | a3ComPollAddressType | 0 | 0 | This defines the method used to interpret the a3ComPollAddress, which implies on the protocol to be used. Writing an address to … |
1.3.6.1.4.1.43.29.4.22.1.1.4 | a3ComPollCount | 0 | 0 | This integer is the number of ping packets to be sent out until completion of a polling command. If count is set to continuous(0… |
1.3.6.1.4.1.43.29.4.22.1.1.5 | a3ComPollAttempts | 0 | 0 | The number of unsuccessful or successful requests necessary before deciding that the device is definitely not responding or resp… |
1.3.6.1.4.1.43.29.4.22.1.1.7 | a3ComPollResponseTimeOut | 0 | 0 | Maximum wait time, in msecs, for a response packet before deciding that no response arrived. This object differs from a3ComPollR… |
1.3.6.1.4.1.43.29.4.22.1.1.8 | a3ComPollPacketSize | 0 | 0 | Size, in bytes, of ping packet to be sent out. If set to 0, the default size for ping packet under the protocol chosen will be u… |
1.3.6.1.4.1.43.29.4.22.1.1.9 | a3ComPollSourceAddress | 0 | 0 | This DisplayString is the network address of the local interface to receive ping query. Typically this is an IP, IPX or AppleTal… |
1.3.6.1.4.1.43.29.4.22.1.1.10 | a3ComPollMinRoundTripTime | 0 | 0 | The minimum amount of time taken, in msecs, for the round trip of a ping packet. |
1.3.6.1.4.1.43.29.4.22.1.1.11 | a3ComPollAvgRoundTripTime | 0 | 0 | The average amount of time taken, in msecs, for the round trip of a ping packet. |
1.3.6.1.4.1.43.29.4.22.1.1.12 | a3ComPollMaxRoundTripTime | 0 | 0 | The maximum amount of time taken, in msecs, for the round trip of a ping packet. |
1.3.6.1.4.1.43.29.4.22.1.1.13 | a3ComPollFramesSent | 0 | 0 | The number of ping packets sent to remote device so far. |
1.3.6.1.4.1.43.29.4.22.1.1.14 | a3ComPollFramesReceived | 0 | 0 | The number of ping packets responded by remote device so far. If a3ComPollResponseTimeOut is a non-zero value, and the poll respo… |
1.3.6.1.4.1.43.29.4.22.1.1.15 | a3ComPollInformation | 0 | 0 | Depending on the protocol being used, this object contains extra information obtained through the device poll. For IP, the value… |
1.3.6.1.4.1.43.29.4.22.1.1.16 | a3ComPollOwner | 0 | 0 | The RMON OwnerString conventions are used here to help control the multi-manager situations. |
1.3.6.1.4.1.43.29.4.22.1.1.17 | a3ComPollReport | 0 | 0 | This integer contains the current status of the poll entry. When the state changes from busy to any other, the entry is no longe… |
1.3.6.1.4.1.43.29.4.22.1.1.18 | a3ComPollAction | 0 | 0 | This object is the trigger for initiating, stopping, resetting and destroying a poll entry. In order to read the current status … |