the value other (1). The result of
setting this object to each acceptable
value is:
runDiagnostics: runs the board's
offline diagnostics.
Sources for this description
MIBdepot
Source file: Download linkb.mib.txt
OID reference
1.3.6.1.4.1.43.7.1.2.1.1.7
This object, when read, always returns the value other (1). The result of setting this object to each acceptable value is: runDiagnostics: runs the board's offline diagnostics.
Identification
{1 3 6 1 4 1 43 7 1 2 1 1 7}
| Value | Name |
|---|---|
| 1 | other |
| 2 | runDiagnostics |
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In LB3GH-1-0-7, the row index slotIndex is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.43.7.1.2.1.1.7.<slotIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.43.7.1.2.1.1.7
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Source file: Download linkb.mib.txt
Historical records
slotBoardAction OBJECT-TYPE
SYNTAX INTEGER {
other(1),
runDiagnostics(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object, when read, always returns
the value other (1). The result of
setting this object to each acceptable
value is:
runDiagnostics: runs the board's
offline diagnostics."
::= { slotEntry 7 }
slotBoardAction OBJECT-TYPE
SYNTAX INTEGER {
other(1),
runDiagnostics(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object, when read, always returns
the value other (1). The result of
setting this object to each acceptable
value is:
runDiagnostics: runs the board's
offline diagnostics."
::= { slotEntry 7 }
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.43.7.1.2.1.1.1 | slotIndex | 0 | 0 | The physical slot number of this slot within the LinkBuilder 3GH chassis. |
| 1.3.6.1.4.1.43.7.1.2.1.1.2 | slotBoardType | 0 | 0 | The type of board residing in this slot. |
| 1.3.6.1.4.1.43.7.1.2.1.1.3 | slotBoardRevision | 0 | 0 | The revision number of the board in this slot. |
| 1.3.6.1.4.1.43.7.1.2.1.1.4 | slotBoardStatus | 0 | 0 | The status of the board in this slot. |
| 1.3.6.1.4.1.43.7.1.2.1.1.5 | slotBoardName | 0 | 0 | The text string describing this board type. |
| 1.3.6.1.4.1.43.7.1.2.1.1.6 | slotBoardNameAbbrev | 0 | 0 | The abbreviation describing this board type. |