A row of Pad Profile configuration parameters
Parsed from file vanguard-65xx-pad.mib.txt
Company: None
Module: PAD-OPT-MIB
A row of Pad Profile configuration parameters
Parsed from file PAD-OPT-MIB.mib
Module: PAD-OPT-MIB
Vendor: Codex
Module: PAD-OPT-MIB
[Automatically extracted from oidview.com]
cdx6500CfgPadProfileEntry OBJECT-TYPE SYNTAX Cdx6500CfgPadProfileEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row of Pad Profile configuration parameters" INDEX { cdx6500padprofProfileNum } ::= { cdx6500CfgPadProfileTable 1 }
cdx6500CfgPadProfileEntry OBJECT-TYPE SYNTAX Cdx6500CfgPadProfileEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row of Pad Profile configuration parameters" INDEX { cdx6500padprofProfileNum } ::= { cdx6500CfgPadProfileTable 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.449.2.1.2.2.8.1.1 | cdx6500padprofProfileNum | 0 | 0 | This is not a configuration parameter. Instead, it identifies the particular PAD Profile Table entry being configured by the othe… |
1.3.6.1.4.1.449.2.1.2.2.8.1.2 | cdx6500padprofProfileName | 0 | 0 | Reference name for this PAD profile. Individual parameter prompt messages are prefixed with X.3 parameter number. Numbers greater… |
1.3.6.1.4.1.449.2.1.2.2.8.1.3 | cdx6500padprofPar1 | 0 | 0 | #1, enables PAD recall to command mode during a call: 0 - PAD recall disabled 1 - PAD recall character = DLE = <^P> 32-126 -…^p> |
1.3.6.1.4.1.449.2.1.2.2.8.1.4 | cdx6500padprofPar2 | 0 | 0 | #2, controls echo: 0 - echo disabled 1 - echo enabled. |
1.3.6.1.4.1.449.2.1.2.2.8.1.5 | cdx6500padprofPar3 | 0 | 0 | #3, selects the ASCII characters used for data forwarding: 0 - no data forwarding characters 1 - A-Z, a-z, 0-9 2 - CR 4 - ESC, BEL,… |
1.3.6.1.4.1.449.2.1.2.2.8.1.6 | cdx6500padprofPar4 | 0 | 0 | #4, selects forwarding idle timer delay: 0 - idle timer disabled 1 to 255 - value of idle timer in 1/20 seconds. |
1.3.6.1.4.1.449.2.1.2.2.8.1.7 | cdx6500padprofPar5 | 0 | 0 | #5, specifies whether the attached terminal is flow controlled (restrained from sending data) by the PAD port sending the XON, XO… |
1.3.6.1.4.1.449.2.1.2.2.8.1.8 | cdx6500padprofPar6 | 0 | 0 | #6, controls PAD service signal messages to the attached device: 0 - no service signal is sent 1 - service signals, other than the… |
1.3.6.1.4.1.449.2.1.2.2.8.1.9 | cdx6500padprofPar7 | 0 | 0 | #7, selects the PAD mode of operation on receipt of a break signal from the attached terminal: 0 - do nothing 1 - send Interrupt p… |
1.3.6.1.4.1.449.2.1.2.2.8.1.10 | cdx6500padprofPar9 | 0 | 0 | #9, controls padding after carriage return (CR): 0 - no padding after CR. 1 to 255 - number of padding characters inserted… |
1.3.6.1.4.1.449.2.1.2.2.8.1.11 | cdx6500padprofPar10 | 0 | 0 | #10, controls line folding: 0 - no line folding. 1 to 255 - number of characters per line. |
1.3.6.1.4.1.449.2.1.2.2.8.1.12 | cdx6500padprofPar12 | 0 | 0 | #12, specifies whether the PAD port is flow controlled (restrained from sending data) by the attached terminal sending the XON, X… |
1.3.6.1.4.1.449.2.1.2.2.8.1.13 | cdx6500padprofPar13 | 0 | 0 | #13, controls line feed insertion after carriage return (CR) in data transfer state: 0 - no line feed insertion 1 - after CR in da… |
1.3.6.1.4.1.449.2.1.2.2.8.1.14 | cdx6500padprofPar14 | 0 | 0 | #14, controls padding after line feed in the data transfer state: 0 - no padding after line feed 1 to 255 - number of paddi… |
1.3.6.1.4.1.449.2.1.2.2.8.1.15 | cdx6500padprofPar15 | 0 | 0 | #15, controls local editing in data transfer state: 0 - no editing 1 - allow editing (idle timer data forwarding must be disabled,… |
1.3.6.1.4.1.449.2.1.2.2.8.1.16 | cdx6500padprofPar16 | 0 | 0 | #16, decimal value of ASCII character used to delete a character if editing is enabled (parameter #15 = 1). |
1.3.6.1.4.1.449.2.1.2.2.8.1.17 | cdx6500padprofPar17 | 0 | 0 | #17, decimal value of ASCII character used to delete a line if editing is enabled (parameter #15 = 1). |
1.3.6.1.4.1.449.2.1.2.2.8.1.18 | cdx6500padprofPar18 | 0 | 0 | #18, decimal value of ASCII character used to display a line if editing is enabled (parameter #15 = 1). |
1.3.6.1.4.1.449.2.1.2.2.8.1.19 | cdx6500padprofPar19 | 0 | 0 | #19, specifies the type of character delete service signal sent by PAD: 0 - no service signal 1 - printing terminals… |
1.3.6.1.4.1.449.2.1.2.2.8.1.20 | cdx6500padprofPar20 | 0 | 0 | #20, specifies the echo mask: 0 - no echo mask (all characters echoed) 1 - no echo of CR 2 - no echo of LF 4 - no echo of VT, HT, o… |
1.3.6.1.4.1.449.2.1.2.2.8.1.21 | cdx6500padprofPar21 | 0 | 0 | #21, controls the parity treatment of characters received and transmitted to the attached device. 0 - No parity checking or gener… |
1.3.6.1.4.1.449.2.1.2.2.8.1.22 | cdx6500padprofPar22 | 0 | 0 | #22, controls page wait: 0 - page wait disabled. 1 to 255 - number of line feed characters sent by the PAD for the page wai… |
1.3.6.1.4.1.449.2.1.2.2.8.1.23 | cdx6500padprofPar100 | 0 | 0 | #100, specifies the ASCII character used to simulate break for attached terminals that do not have a break key: 0 - no bre… |
1.3.6.1.4.1.449.2.1.2.2.8.1.24 | cdx6500padprofPar101 | 0 | 0 | #101, specifies the ASCII character used to toggle echo substitution of entered data. This function available only if parameter #… |
1.3.6.1.4.1.449.2.1.2.2.8.1.25 | cdx6500padprofPar102 | 0 | 0 | #102, specifies the ASCII character used to echo all characters entered by the attached device when echo substitution is toggled … |
1.3.6.1.4.1.449.2.1.2.2.8.1.26 | cdx6500padprofPar103 | 0 | 0 | #103, specifies the ASCII character used for the XON function: 0 to 255 - decimal value of the XON character |
1.3.6.1.4.1.449.2.1.2.2.8.1.27 | cdx6500padprofPar104 | 0 | 0 | #104, specifies the ASCII character used for the XOFF function: 0 to 255 - decimal value of the XOFF character. |
1.3.6.1.4.1.449.2.1.2.2.8.1.28 | cdx6500padprofPar105 | 0 | 0 | #105, specifies whether both the PAD and the attached terminal are flow controlled (restrained from sending data) by the use of V… |
1.3.6.1.4.1.449.2.1.2.2.8.1.29 | cdx6500padprofPar106 | 0 | 0 | #106, specifies parity of data sent to the network by the PAD: 0 - transparent - pass data as received 1 - space 2 - mark 3 - even 4… |
1.3.6.1.4.1.449.2.1.2.2.8.1.30 | cdx6500padprofPar107 | 0 | 0 | #107, is the elapsed time of no user data input after which a call on the port will be cleared: 0 - timer disabled 1 to 255… |
1.3.6.1.4.1.449.2.1.2.2.8.1.31 | cdx6500padprofPar108 | 0 | 0 | #108, specifies the ASCII character used to disconnect a call: 0 - no character disconnects the call. 1 to 127 - decimal v… |
1.3.6.1.4.1.449.2.1.2.2.8.1.32 | cdx6500padprofPar109 | 0 | 0 | #109, specifies the number of padding characters inserted in the data sent to the attached device after a form feed: 0 - n… |
1.3.6.1.4.1.449.2.1.2.2.8.1.33 | cdx6500padprofPar110 | 0 | 0 | #110, Selects the data forwarding delay after ESC is detected 0 - timer disabled. 1 to 255 - timer value in 1/20 second. |
1.3.6.1.4.1.449.2.1.2.2.8.1.34 | cdx6500padprofPar111 | 0 | 0 | #111, Controls how the pad handles the echo of data when echo, parameter 2, is on. 0 - No Priority. Data is output and cha… |
1.3.6.1.4.1.449.2.1.2.2.8.1.35 | cdx6500padprofPar112 | 0 | 0 | #112, Setting this parameter causes the PAD port to dynamically forward data packets, as bandwidth becomes available on the netwo… |
1.3.6.1.4.1.449.2.1.2.2.8.1.36 | cdx6500padprofPar113 | 0 | 0 | #113, Controls Hewlett-Packard flow control. 0 - No HP flow control. 1 - HP host enq/ack control. 2 - HP term… |
1.3.6.1.4.1.449.2.1.2.2.8.1.37 | cdx6500padprofPar114 | 0 | 0 | #114, Selects PAD operational mode: 0 - Normal PAD. 1 - Transparent Polled Async Host PAD. 2 - Transparent Po… |
1.3.6.1.4.1.449.2.1.2.2.8.1.38 | cdx6500padprofPar115 | 0 | 0 | #115, Selects Data Forwarding Criteria for Polled Async PADs: 0 - Normal. 1 - Short Timer. 2 - RTS Signal Drop. |
1.3.6.1.4.1.449.2.1.2.2.8.1.39 | cdx6500padprofPar116 | 0 | 0 | #116, Selects forwarding Short Timer duration for Polled Async PADs: 0 - Short Timer disabled. 1 to 255 - Duration of Short… |
1.3.6.1.4.1.449.2.1.2.2.8.1.40 | cdx6500padprofPar117 | 0 | 0 | #117, Selects EIA Signalling Action for Polled Async PADs: 0 - None. 1 - Raise DCD before transmission and drop DCD… |
1.3.6.1.4.1.449.2.1.2.2.8.1.41 | cdx6500padprofPar118 | 0 | 0 | #118, Setting this parameter causes a Polled Async PAD to buffer complete async messages from the network before transmitting the… |
1.3.6.1.4.1.449.2.1.2.2.8.1.42 | cdx6500padprofPar119 | 0 | 0 | #119, This parameter specifies the amount of time that DCD is held high before data transmission to the attached device begins. T… |