Reference record for OID 1.3.6.1.4.1.449.2.1.2.2.8.1.28



parent
1.3.6.1.4.1.449.2.1.2.2.8.1 (cdx6500CfgPadProfileEntry)
node code
28
node name
cdx6500padprofPar105
dot oid
1.3.6.1.4.1.449.2.1.2.2.8.1.28
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) codex(449) cdxProductSpecific(2) cdx6500(1) cdx6500Configuration(2) cdx6500CfgGeneralGroup(2) cdx6500CfgPadProfileTable(8) cdx6500CfgPadProfileEntry(1) cdx6500padprofPar105(28)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) codex(449) cdxProductSpecific(2) cdx6500(1) cdx6500Configuration(2) cdx6500CfgGeneralGroup(2) cdx6500CfgPadProfileTable(8) cdx6500CfgPadProfileEntry(1) cdx6500padprofPar105(28)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) codex(449) cdxProductSpecific(2) cdx6500(1) cdx6500Configuration(2) cdx6500CfgGeneralGroup(2) cdx6500CfgPadProfileTable(8) cdx6500CfgPadProfileEntry(1) cdx6500padprofPar105(28)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) codex(449) cdxProductSpecific(2) cdx6500(1) cdx6500Configuration(2) cdx6500CfgGeneralGroup(2) cdx6500CfgPadProfileTable(8) cdx6500CfgPadProfileEntry(1) cdx6500padprofPar105(28)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) codex(449) cdxProductSpecific(2) cdx6500(1) cdx6500Configuration(2) cdx6500CfgGeneralGroup(2) cdx6500CfgPadProfileTable(8) cdx6500CfgPadProfileEntry(1) cdx6500padprofPar105(28)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) codex(449) cdxProductSpecific(2) cdx6500(1) cdx6500Configuration(2) cdx6500CfgGeneralGroup(2) cdx6500CfgPadProfileTable(8) cdx6500CfgPadProfileEntry(1) cdx6500padprofPar105(28)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/codex/cdxProductSpecific/cdx6500/cdx6500Configuration/cdx6500CfgGeneralGroup/cdx6500CfgPadProfileTable/cdx6500CfgPadProfileEntry/cdx6500padprofPar105
  • /iso/identified-organization/dod/internet/private/enterprises/codex/cdxProductSpecific/cdx6500/cdx6500Configuration/cdx6500CfgGeneralGroup/cdx6500CfgPadProfileTable/cdx6500CfgPadProfileEntry/cdx6500padprofPar105
  • /iso/org/dod/internet/private/enterprise/codex/cdxProductSpecific/cdx6500/cdx6500Configuration/cdx6500CfgGeneralGroup/cdx6500CfgPadProfileTable/cdx6500CfgPadProfileEntry/cdx6500padprofPar105
  • /iso/org/dod/internet/private/enterprises/codex/cdxProductSpecific/cdx6500/cdx6500Configuration/cdx6500CfgGeneralGroup/cdx6500CfgPadProfileTable/cdx6500CfgPadProfileEntry/cdx6500padprofPar105
  • /iso/iso-identified-organization/dod/internet/private/enterprise/codex/cdxProductSpecific/cdx6500/cdx6500Configuration/cdx6500CfgGeneralGroup/cdx6500CfgPadProfileTable/cdx6500CfgPadProfileEntry/cdx6500padprofPar105
  • /iso/iso-identified-organization/dod/internet/private/enterprises/codex/cdxProductSpecific/cdx6500/cdx6500Configuration/cdx6500CfgGeneralGroup/cdx6500CfgPadProfileTable/cdx6500CfgPadProfileEntry/cdx6500padprofPar105
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/449/2/1/2/2/8/1/28

    Description by mibdepot

    #105, specifies whether both the PAD and the attached
    terminal are flow controlled (restrained from sending data)
    by the use of V.24 control signals, rather than XON, XOFF.
    This type of control is called out-of-band flow control.
    The control applies to data, commands and responses to and
    from an attached device:
    0 - none using connector control signals
    1 - Data Restraint Outbound, attached device flow controls
    PAD with connector pin 14
    2 - Data Restraint Inbound, PAD flow controls attached device
    with connector pin 5, CTS
    X - any combination formed by summing (e.g. 1+2 or 3)
    For DRO control using XON/XOFF, use parameters #5 and #12.

    Parsed from file vanguard-65xx-pad.mib.txt
    Company: None
    Module: PAD-OPT-MIB

    Description by circitor

    #105, specifies whether both the PAD and the attached
    terminal are flow controlled (restrained from sending data)
    by the use of V.24 control signals, rather than XON, XOFF.
    This type of control is called out-of-band flow control.
    The control applies to data, commands and responses to and
    from an attached device:
    0 - none using connector control signals
    1 - Data Restraint Outbound, attached device flow controls
    PAD with connector pin 14
    2 - Data Restraint Inbound, PAD flow controls attached device
    with connector pin 5, CTS
    X - any combination formed by summing (e.g. 1+2 or 3)
    For DRO control using XON/XOFF, use parameters #5 and #12.

    Parsed from file PAD-OPT-MIB.mib
    Module: PAD-OPT-MIB

    Information by oid_info

    Vendor: Codex
    Module: PAD-OPT-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    cdx6500padprofPar105 OBJECT-TYPE SYNTAX DisplayString (SIZE(1..5)) ACCESS read-only STATUS mandatory DESCRIPTION "#105, specifies whether both the PAD and the attached terminal are flow controlled (restrained from sending data) by the use of V.24 control signals, rather than XON, XOFF. This type of control is called out-of-band flow control. The control applies to data, commands and responses to and from an attached device: 0 - none using connector control signals 1 - Data Restraint Outbound, attached device flow controls PAD with connector pin 14 2 - Data Restraint Inbound, PAD flow controls attached device with connector pin 5, CTS X - any combination formed by summing (e.g. 1+2 or 3) For DRO control using XON/XOFF, use parameters #5 and #12." ::= { cdx6500CfgPadProfileEntry 28 }

    Information by circitor

    cdx6500padprofPar105 OBJECT-TYPE SYNTAX DisplayString (SIZE(1..5)) ACCESS read-only STATUS mandatory DESCRIPTION "#105, specifies whether both the PAD and the attached terminal are flow controlled (restrained from sending data) by the use of V.24 control signals, rather than XON, XOFF. This type of control is called out-of-band flow control. The control applies to data, commands and responses to and from an attached device: 0 - none using connector control signals 1 - Data Restraint Outbound, attached device flow controls PAD with connector pin 14 2 - Data Restraint Inbound, PAD flow controls attached device with connector pin 5, CTS X - any combination formed by summing (e.g. 1+2 or 3) For DRO control using XON/XOFF, use parameters #5 and #12." ::= { cdx6500CfgPadProfileEntry 28 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.449)

    McGinty Thomas

    Brothers (41)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.449.2.1.2.2.8.1.1 cdx6500padprofProfileNum 0 0 This is not a configuration parameter. Instead, it
    identifies the particular PAD Profile Table entry
    being configured by the othe…
    1.3.6.1.4.1.449.2.1.2.2.8.1.2 cdx6500padprofProfileName 0 0 Reference name for this PAD profile. Individual parameter
    prompt messages are prefixed with X.3 parameter number.
    Numbers greater…
    1.3.6.1.4.1.449.2.1.2.2.8.1.3 cdx6500padprofPar1 0 0 #1, enables PAD recall to command mode during a call:
    0 - PAD recall disabled
    1 - PAD recall character = DLE = <^P>
    32-126 -…
    1.3.6.1.4.1.449.2.1.2.2.8.1.4 cdx6500padprofPar2 0 0 #2, controls echo:
    0 - echo disabled
    1 - echo enabled.
    1.3.6.1.4.1.449.2.1.2.2.8.1.5 cdx6500padprofPar3 0 0 #3, selects the ASCII characters used for data forwarding:
    0 - no data forwarding characters
    1 - A-Z, a-z, 0-9
    2 - CR
    4 - ESC, BEL,…
    1.3.6.1.4.1.449.2.1.2.2.8.1.6 cdx6500padprofPar4 0 0 #4, selects forwarding idle timer delay:
    0 - idle timer disabled
    1 to 255 - value of idle timer in 1/20 seconds.
    1.3.6.1.4.1.449.2.1.2.2.8.1.7 cdx6500padprofPar5 0 0 #5, specifies whether the attached terminal is flow
    controlled (restrained from sending data) by the PAD port
    sending the XON, XO…
    1.3.6.1.4.1.449.2.1.2.2.8.1.8 cdx6500padprofPar6 0 0 #6, controls PAD service signal messages to the attached
    device:
    0 - no service signal is sent
    1 - service signals, other than the…
    1.3.6.1.4.1.449.2.1.2.2.8.1.9 cdx6500padprofPar7 0 0 #7, selects the PAD mode of operation on receipt of a break
    signal from the attached terminal:
    0 - do nothing
    1 - send Interrupt p…
    1.3.6.1.4.1.449.2.1.2.2.8.1.10 cdx6500padprofPar9 0 0 #9, controls padding after carriage return (CR):
    0 - no padding after CR.
    1 to 255 - number of padding characters inserted…
    1.3.6.1.4.1.449.2.1.2.2.8.1.11 cdx6500padprofPar10 0 0 #10, controls line folding:
    0 - no line folding.
    1 to 255 - number of characters per line.
    1.3.6.1.4.1.449.2.1.2.2.8.1.12 cdx6500padprofPar12 0 0 #12, specifies whether the PAD port is flow controlled
    (restrained from sending data) by the attached terminal
    sending the XON, X…
    1.3.6.1.4.1.449.2.1.2.2.8.1.13 cdx6500padprofPar13 0 0 #13, controls line feed insertion after carriage return (CR)
    in data transfer state:
    0 - no line feed insertion
    1 - after CR in da…
    1.3.6.1.4.1.449.2.1.2.2.8.1.14 cdx6500padprofPar14 0 0 #14, controls padding after line feed in the data transfer
    state:
    0 - no padding after line feed
    1 to 255 - number of paddi…
    1.3.6.1.4.1.449.2.1.2.2.8.1.15 cdx6500padprofPar15 0 0 #15, controls local editing in data transfer state:
    0 - no editing
    1 - allow editing (idle timer data forwarding must be
    disabled,…
    1.3.6.1.4.1.449.2.1.2.2.8.1.16 cdx6500padprofPar16 0 0 #16, decimal value of ASCII character used to delete a
    character if editing is enabled (parameter #15 = 1).
    1.3.6.1.4.1.449.2.1.2.2.8.1.17 cdx6500padprofPar17 0 0 #17, decimal value of ASCII character used to delete a line
    if editing is enabled (parameter #15 = 1).
    1.3.6.1.4.1.449.2.1.2.2.8.1.18 cdx6500padprofPar18 0 0 #18, decimal value of ASCII character used to display a line
    if editing is enabled (parameter #15 = 1).
    1.3.6.1.4.1.449.2.1.2.2.8.1.19 cdx6500padprofPar19 0 0 #19, specifies the type of character delete service signal
    sent by PAD:
    0 - no service signal
    1 - printing terminals…
    1.3.6.1.4.1.449.2.1.2.2.8.1.20 cdx6500padprofPar20 0 0 #20, specifies the echo mask:
    0 - no echo mask (all characters echoed)
    1 - no echo of CR
    2 - no echo of LF
    4 - no echo of VT, HT, o…
    1.3.6.1.4.1.449.2.1.2.2.8.1.21 cdx6500padprofPar21 0 0 #21, controls the parity treatment of characters received and
    transmitted to the attached device.
    0 - No parity checking or gener…
    1.3.6.1.4.1.449.2.1.2.2.8.1.22 cdx6500padprofPar22 0 0 #22, controls page wait:
    0 - page wait disabled.
    1 to 255 - number of line feed characters sent
    by the PAD for the page wai…
    1.3.6.1.4.1.449.2.1.2.2.8.1.23 cdx6500padprofPar100 0 0 #100, specifies the ASCII character used to simulate break
    for attached terminals that do not have a break key:
    0 - no bre…
    1.3.6.1.4.1.449.2.1.2.2.8.1.24 cdx6500padprofPar101 0 0 #101, specifies the ASCII character used to toggle echo
    substitution of entered data. This function available only
    if parameter #…
    1.3.6.1.4.1.449.2.1.2.2.8.1.25 cdx6500padprofPar102 0 0 #102, specifies the ASCII character used to echo all
    characters entered by the attached device when echo
    substitution is toggled …
    1.3.6.1.4.1.449.2.1.2.2.8.1.26 cdx6500padprofPar103 0 0 #103, specifies the ASCII character used for the XON
    function:
    0 to 255 - decimal value of the XON character
    1.3.6.1.4.1.449.2.1.2.2.8.1.27 cdx6500padprofPar104 0 0 #104, specifies the ASCII character used for the XOFF
    function:
    0 to 255 - decimal value of the XOFF character.
    1.3.6.1.4.1.449.2.1.2.2.8.1.29 cdx6500padprofPar106 0 0 #106, specifies parity of data sent to the network by the PAD:
    0 - transparent - pass data as received
    1 - space
    2 - mark
    3 - even
    4…
    1.3.6.1.4.1.449.2.1.2.2.8.1.30 cdx6500padprofPar107 0 0 #107, is the elapsed time of no user data input after which
    a call on the port will be cleared:
    0 - timer disabled
    1 to 255…
    1.3.6.1.4.1.449.2.1.2.2.8.1.31 cdx6500padprofPar108 0 0 #108, specifies the ASCII character used to disconnect a call:
    0 - no character disconnects the call.
    1 to 127 - decimal v…
    1.3.6.1.4.1.449.2.1.2.2.8.1.32 cdx6500padprofPar109 0 0 #109, specifies the number of padding characters inserted
    in the data sent to the attached device after a form feed:
    0 - n…
    1.3.6.1.4.1.449.2.1.2.2.8.1.33 cdx6500padprofPar110 0 0 #110, Selects the data forwarding delay after ESC is detected
    0 - timer disabled.
    1 to 255 - timer value in 1/20 second.
    1.3.6.1.4.1.449.2.1.2.2.8.1.34 cdx6500padprofPar111 0 0 #111, Controls how the pad handles the echo of data when echo,
    parameter 2, is on.
    0 - No Priority. Data is output and cha…
    1.3.6.1.4.1.449.2.1.2.2.8.1.35 cdx6500padprofPar112 0 0 #112, Setting this parameter causes the PAD port to
    dynamically forward data packets, as bandwidth becomes
    available on the netwo…
    1.3.6.1.4.1.449.2.1.2.2.8.1.36 cdx6500padprofPar113 0 0 #113, Controls Hewlett-Packard flow control.
    0 - No HP flow control.
    1 - HP host enq/ack control.
    2 - HP term…
    1.3.6.1.4.1.449.2.1.2.2.8.1.37 cdx6500padprofPar114 0 0 #114, Selects PAD operational mode:
    0 - Normal PAD.
    1 - Transparent Polled Async Host PAD.
    2 - Transparent Po…
    1.3.6.1.4.1.449.2.1.2.2.8.1.38 cdx6500padprofPar115 0 0 #115, Selects Data Forwarding Criteria for Polled Async
    PADs:
    0 - Normal.
    1 - Short Timer.
    2 - RTS Signal Drop.
    1.3.6.1.4.1.449.2.1.2.2.8.1.39 cdx6500padprofPar116 0 0 #116, Selects forwarding Short Timer duration for Polled
    Async PADs:
    0 - Short Timer disabled.
    1 to 255 - Duration of Short…
    1.3.6.1.4.1.449.2.1.2.2.8.1.40 cdx6500padprofPar117 0 0 #117, Selects EIA Signalling Action for Polled Async PADs:
    0 - None.
    1 - Raise DCD before transmission and drop DCD…
    1.3.6.1.4.1.449.2.1.2.2.8.1.41 cdx6500padprofPar118 0 0 #118, Setting this parameter causes a Polled Async PAD to
    buffer complete async messages from the network before
    transmitting the…
    1.3.6.1.4.1.449.2.1.2.2.8.1.42 cdx6500padprofPar119 0 0 #119, This parameter specifies the amount of time that
    DCD is held high before data transmission to the attached
    device begins. T…