A table with redundancy status and control for
each redundancy-capable port in the chassis.
The number of entries is determined by the number
of redundancy-capable ports in the chassis.
The ports appearing in this table can be divided into
two categories:
Those with remote fault signaling capability and
those without. The latter kind depends on the port
link status to provide the required redundancy.
Ports that are not capable of supporting redundancy do
not have an entry in this table.
Parsed from file S5erl102.mib.txt
Company: None
Module: S5-ETH-REDUNDANT-LINKS-MIB
A table with redundancy status and control for
each redundancy-capable port in the chassis.
The number of entries is determined by the number
of redundancy-capable ports in the chassis.
The ports appearing in this table can be divided into
two categories:
Those with remote fault signaling capability and
those without. The latter kind depends on the port
link status to provide the required redundancy.
Ports that are not capable of supporting redundancy do
not have an entry in this table.
Parsed from file S5-ETH-REDUNDANT-LINKS-MIB.mib
Module: S5-ETH-REDUNDANT-LINKS-MIB
Vendor: SynOptics
Module: S5-ETH-REDUNDANT-LINKS-MIB
[Automatically extracted from oidview.com]
s5EnRedPortTable OBJECT-TYPE SYNTAX SEQUENCE OF S5EnRedPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table with redundancy status and control for each redundancy-capable port in the chassis. The number of entries is determined by the number of redundancy-capable ports in the chassis. The ports appearing in this table can be divided into two categories: Those with remote fault signaling capability and those without. The latter kind depends on the port link status to provide the required redundancy. Ports that are not capable of supporting redundancy do not have an entry in this table." ::= { s5EnRedun 1 }
s5EnRedPortTable OBJECT-TYPE SYNTAX SEQUENCE OF S5EnRedPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table with redundancy status and control for each redundancy-capable port in the chassis. The number of entries is determined by the number of redundancy-capable ports in the chassis. The ports appearing in this table can be divided into two categories: Those with remote fault signaling capability and those without. The latter kind depends on the port link status to provide the required redundancy. Ports that are not capable of supporting redundancy do not have an entry in this table." ::= { s5EnRedun 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.45.1.6.6.1.2.1.1 | s5EnRedPortEntry | 14 | 14 | A row in the table of redundancy status and control for each redundancy-capable port in the chassis. Entries in the table cannot … |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.45.1.6.6.1.2.2 | s5EnRedLastChg | 1 | 1 | The value of sysUpTime when the last change in the redundant ports table was observed by the agent. |