Current Status (Operational Status) of this SS7 Circuit.
'SET' Operation is NOT APPLICABLE.
For the 'GET' Operation, the possible options are
1) active
2) down
3) block
Parsed from file A2000.mib.txt
Company: None
Module: ARMILLAIRE2000-MIB
Current Status (Operational Status) of this SS7 Circuit.
'SET' Operation is NOT APPLICABLE.
For the 'GET' Operation, the possible options are
1) active
2) down
3) block
Parsed from file ARMILLAIRE2000-MIB.mib
Module: ARMILLAIRE2000-MIB
Vendor: ARMILLAIRE TECHNOLOGIES
Module: ARMILLAIRE2000-MIB
[Automatically extracted from oidview.com]
ss7CktOpStatus OBJECT-TYPE SYNTAX CktOpStatus ACCESS read-only STATUS mandatory DESCRIPTION "Current Status (Operational Status) of this SS7 Circuit. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down 3) block " ::= { ss7CktCfgEntry 17 }
ss7CktOpStatus OBJECT-TYPE SYNTAX CktOpStatus ACCESS read-only STATUS mandatory DESCRIPTION "Current Status (Operational Status) of this SS7 Circuit. 'SET' Operation is NOT APPLICABLE. For the 'GET' Operation, the possible options are 1) active 2) down 3) block " ::= { ss7CktCfgEntry 17 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.4618.1.2.2.1.2.2.1.1 | ss7CktTrunkId | 0 | 0 | User Assigned Trunk id. |
1.3.6.1.4.1.4618.1.2.2.1.2.2.1.2 | ss7CktChnlId | 0 | 0 | User Assigned Channel id |
1.3.6.1.4.1.4618.1.2.2.1.2.2.1.3 | ss7CktId | 0 | 0 | Circuit id. The Id assingned to each of the circuits for a particular Trunk. |
1.3.6.1.4.1.4618.1.2.2.1.2.2.1.4 | ss7CktDpc | 0 | 0 | Destination Point Code (The Integer Value). The Point Code should be converted into its Integer equivalent. For Example: 0-1-1 is … |
1.3.6.1.4.1.4618.1.2.2.1.2.2.1.5 | ss7CktCic | 0 | 0 | Circuit identifier code. Can be any integer from 1) 1-4095 for ITU 2) 1-16383 for ANSI |
1.3.6.1.4.1.4618.1.2.2.1.2.2.1.6 | ss7CktDir | 0 | 0 | Traffic direction: Possible options are : 1) IN 2) OUT 3) BOTH |
1.3.6.1.4.1.4618.1.2.2.1.2.2.1.7 | ss7CktPriority | 0 | 0 | Traffic priority |
1.3.6.1.4.1.4618.1.2.2.1.2.2.1.8 | ss7CktT3 | 0 | 0 | T3 timer. Default Value is 0 milliSeconds |
1.3.6.1.4.1.4618.1.2.2.1.2.2.1.9 | ss7CktT12 | 0 | 0 | T12 timer - blocking sent. Default Value is 40 milliSeconds |
1.3.6.1.4.1.4618.1.2.2.1.2.2.1.10 | ss7CktT13 | 0 | 0 | T13 timer - initial blocking sent. Default Value is 600 milliSeconds |
1.3.6.1.4.1.4618.1.2.2.1.2.2.1.11 | ss7CktT14 | 0 | 0 | T14 timer - unblocking sent. Default Value is 40 milliSeconds |
1.3.6.1.4.1.4618.1.2.2.1.2.2.1.12 | ss7CktT15 | 0 | 0 | T15 timer - initial unblocking sent. Default Value is 600 milliSeconds |
1.3.6.1.4.1.4618.1.2.2.1.2.2.1.13 | ss7CktT16 | 0 | 0 | T16 timer - reset sent. Default Value is 40 milliSeconds |
1.3.6.1.4.1.4618.1.2.2.1.2.2.1.14 | ss7CktT17 | 0 | 0 | T17 timer - initial reset sent. Default Value is 600 milliSeconds |
1.3.6.1.4.1.4618.1.2.2.1.2.2.1.15 | ss7CktTVal | 0 | 0 | TVal timer - initial reset sent. Default Value is 100 milliSeconds |
1.3.6.1.4.1.4618.1.2.2.1.2.2.1.16 | ss7CktRowStatus | 0 | 0 | Current Status (configurational Status) of this SS7 Circuit. To Configure this circuit, the only option is 'CREATEANDWAIT'. To De… |