Destination Point Code (The Integer Value).
The Point Code should be converted into its Integer
equivalent. For Example:
0-1-1 is converted as 257 (for ANSI)
0-1-2 is converted as 10 (for ITU)
Parsed from file A2000.mib.txt
Company: None
Module: ARMILLAIRE2000-MIB
Destination Point Code (The Integer Value).
The Point Code should be converted into its Integer
equivalent. For Example:
0-1-1 is converted as 257 (for ANSI)
0-1-2 is converted as 10 (for ITU)
Parsed from file ARMILLAIRE2000-MIB.mib
Module: ARMILLAIRE2000-MIB
Vendor: ARMILLAIRE TECHNOLOGIES
Module: ARMILLAIRE2000-MIB
[Automatically extracted from oidview.com]
ss7CktDpc OBJECT-TYPE SYNTAX INTEGER(1..16777215) ACCESS read-write STATUS mandatory DESCRIPTION "Destination Point Code (The Integer Value). The Point Code should be converted into its Integer equivalent. For Example: 0-1-1 is converted as 257 (for ANSI) 0-1-2 is converted as 10 (for ITU) " ::= { ss7CktCfgEntry 4 }
ss7CktDpc OBJECT-TYPE SYNTAX INTEGER(1..16777215) ACCESS read-write STATUS mandatory DESCRIPTION "Destination Point Code (The Integer Value). The Point Code should be converted into its Integer equivalent. For Example: 0-1-1 is converted as 257 (for ANSI) 0-1-2 is converted as 10 (for ITU) " ::= { ss7CktCfgEntry 4 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.4618.1.2.2.1.2.2.1.1 | ss7CktTrunkId | 0 | 0 | User Assigned Trunk id. |
1.3.6.1.4.1.4618.1.2.2.1.2.2.1.2 | ss7CktChnlId | 0 | 0 | User Assigned Channel id |
1.3.6.1.4.1.4618.1.2.2.1.2.2.1.3 | ss7CktId | 0 | 0 | Circuit id. The Id assingned to each of the circuits for a particular Trunk. |
1.3.6.1.4.1.4618.1.2.2.1.2.2.1.5 | ss7CktCic | 0 | 0 | Circuit identifier code. Can be any integer from 1) 1-4095 for ITU 2) 1-16383 for ANSI |
1.3.6.1.4.1.4618.1.2.2.1.2.2.1.6 | ss7CktDir | 0 | 0 | Traffic direction: Possible options are : 1) IN 2) OUT 3) BOTH |
1.3.6.1.4.1.4618.1.2.2.1.2.2.1.7 | ss7CktPriority | 0 | 0 | Traffic priority |
1.3.6.1.4.1.4618.1.2.2.1.2.2.1.8 | ss7CktT3 | 0 | 0 | T3 timer. Default Value is 0 milliSeconds |
1.3.6.1.4.1.4618.1.2.2.1.2.2.1.9 | ss7CktT12 | 0 | 0 | T12 timer - blocking sent. Default Value is 40 milliSeconds |
1.3.6.1.4.1.4618.1.2.2.1.2.2.1.10 | ss7CktT13 | 0 | 0 | T13 timer - initial blocking sent. Default Value is 600 milliSeconds |
1.3.6.1.4.1.4618.1.2.2.1.2.2.1.11 | ss7CktT14 | 0 | 0 | T14 timer - unblocking sent. Default Value is 40 milliSeconds |
1.3.6.1.4.1.4618.1.2.2.1.2.2.1.12 | ss7CktT15 | 0 | 0 | T15 timer - initial unblocking sent. Default Value is 600 milliSeconds |
1.3.6.1.4.1.4618.1.2.2.1.2.2.1.13 | ss7CktT16 | 0 | 0 | T16 timer - reset sent. Default Value is 40 milliSeconds |
1.3.6.1.4.1.4618.1.2.2.1.2.2.1.14 | ss7CktT17 | 0 | 0 | T17 timer - initial reset sent. Default Value is 600 milliSeconds |
1.3.6.1.4.1.4618.1.2.2.1.2.2.1.15 | ss7CktTVal | 0 | 0 | TVal timer - initial reset sent. Default Value is 100 milliSeconds |
1.3.6.1.4.1.4618.1.2.2.1.2.2.1.16 | ss7CktRowStatus | 0 | 0 | Current Status (configurational Status) of this SS7 Circuit. To Configure this circuit, the only option is 'CREATEANDWAIT'. To De… |