Reference record for OID 1.3.6.1.4.1.476.1.42.3.5.2.3.1.15



parent
1.3.6.1.4.1.476.1.42.3.5.2.3.1 (lgpPwrLineMeasurementEntry)
node code
15
node name
lgpPwrLineMeasurementPowerFactorTag
dot oid
1.3.6.1.4.1.476.1.42.3.5.2.3.1.15
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) emerson(476) liebertCorp(1) liebertGlobalProducts(42) lgpFoundation(3) lgpPower(5) lgpPwrMeasurements(2) lgpPwrLineMeasurementTable(3) lgpPwrLineMeasurementEntry(1) lgpPwrLineMeasurementPowerFactorTag(15)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) emerson(476) liebertCorp(1) liebertGlobalProducts(42) lgpFoundation(3) lgpPower(5) lgpPwrMeasurements(2) lgpPwrLineMeasurementTable(3) lgpPwrLineMeasurementEntry(1) lgpPwrLineMeasurementPowerFactorTag(15)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) emerson(476) liebertCorp(1) liebertGlobalProducts(42) lgpFoundation(3) lgpPower(5) lgpPwrMeasurements(2) lgpPwrLineMeasurementTable(3) lgpPwrLineMeasurementEntry(1) lgpPwrLineMeasurementPowerFactorTag(15)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) emerson(476) liebertCorp(1) liebertGlobalProducts(42) lgpFoundation(3) lgpPower(5) lgpPwrMeasurements(2) lgpPwrLineMeasurementTable(3) lgpPwrLineMeasurementEntry(1) lgpPwrLineMeasurementPowerFactorTag(15)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) emerson(476) liebertCorp(1) liebertGlobalProducts(42) lgpFoundation(3) lgpPower(5) lgpPwrMeasurements(2) lgpPwrLineMeasurementTable(3) lgpPwrLineMeasurementEntry(1) lgpPwrLineMeasurementPowerFactorTag(15)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) emerson(476) liebertCorp(1) liebertGlobalProducts(42) lgpFoundation(3) lgpPower(5) lgpPwrMeasurements(2) lgpPwrLineMeasurementTable(3) lgpPwrLineMeasurementEntry(1) lgpPwrLineMeasurementPowerFactorTag(15)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/emerson/liebertCorp/liebertGlobalProducts/lgpFoundation/lgpPower/lgpPwrMeasurements/lgpPwrLineMeasurementTable/lgpPwrLineMeasurementEntry/lgpPwrLineMeasurementPowerFactorTag
  • /iso/identified-organization/dod/internet/private/enterprises/emerson/liebertCorp/liebertGlobalProducts/lgpFoundation/lgpPower/lgpPwrMeasurements/lgpPwrLineMeasurementTable/lgpPwrLineMeasurementEntry/lgpPwrLineMeasurementPowerFactorTag
  • /iso/org/dod/internet/private/enterprise/emerson/liebertCorp/liebertGlobalProducts/lgpFoundation/lgpPower/lgpPwrMeasurements/lgpPwrLineMeasurementTable/lgpPwrLineMeasurementEntry/lgpPwrLineMeasurementPowerFactorTag
  • /iso/org/dod/internet/private/enterprises/emerson/liebertCorp/liebertGlobalProducts/lgpFoundation/lgpPower/lgpPwrMeasurements/lgpPwrLineMeasurementTable/lgpPwrLineMeasurementEntry/lgpPwrLineMeasurementPowerFactorTag
  • /iso/iso-identified-organization/dod/internet/private/enterprise/emerson/liebertCorp/liebertGlobalProducts/lgpFoundation/lgpPower/lgpPwrMeasurements/lgpPwrLineMeasurementTable/lgpPwrLineMeasurementEntry/lgpPwrLineMeasurementPowerFactorTag
  • /iso/iso-identified-organization/dod/internet/private/enterprises/emerson/liebertCorp/liebertGlobalProducts/lgpFoundation/lgpPower/lgpPwrMeasurements/lgpPwrLineMeasurementTable/lgpPwrLineMeasurementEntry/lgpPwrLineMeasurementPowerFactorTag
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/476/1/42/3/5/2/3/1/15

    Description by mibdepot

    The present description of the Power Factor for the line. If
    Leading, the load is said to be capacitive and the phase of the
    current leads the voltage. If Lagging, the load is said to be
    inductive and the phase of the current lags the voltage.

    Parsed from file LIEBERT_GP_POWER.MIB.txt
    Company: None
    Module: LIEBERT-GP-POWER-MIB

    Description by circitor

    The present description of the Power Factor for the line. If
    Leading, the load is said to be capacitive and the phase of the
    current leads the voltage. If Lagging, the load is said to be
    inductive and the phase of the current lags the voltage.

    Parsed from file LIEBERT-GP-POWER-MIB.mib
    Module: LIEBERT-GP-POWER-MIB

    Information by oid_info

    Vendor: Emerson Computer PowerRoger Draper
    Module: LIEBERT-GP-POWER-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    lgpPwrLineMeasurementPowerFactorTag OBJECT-TYPE SYNTAX INTEGER { leading(1), lagging(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The present description of the Power Factor for the line. If Leading, the load is said to be capacitive and the phase of the current leads the voltage. If Lagging, the load is said to be inductive and the phase of the current lags the voltage." ::= { lgpPwrLineMeasurementEntry 15 }

    Information by circitor

    lgpPwrLineMeasurementPowerFactorTag OBJECT-TYPE SYNTAX INTEGER {leading(1), lagging(2)} MAX-ACCESS read-only STATUS current DESCRIPTION "The present description of the Power Factor for the line. If Leading, the load is said to be capacitive and the phase of the current leads the voltage. If Lagging, the load is said to be inductive and the phase of the current lags the voltage." ::= { lgpPwrLineMeasurementEntry 15 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.476)

    [email protected]

    Brothers (20)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.476.1.42.3.5.2.3.1.1 lgpPwrMeasurementPtIndex 0 0 This is the index indicating the row of the table
    'lgpPwrMeasurementPointTable' for a power measurement point.
    1.3.6.1.4.1.476.1.42.3.5.2.3.1.2 lgpPwrLineMeasurementIndex 0 0 This is the index indicating the row of the table
    'lgpPwrLineMeasurementTable' for a power measurement point.
    1.3.6.1.4.1.476.1.42.3.5.2.3.1.3 lgpPwrMeasurementPoint 0 0 An OID representing a well known measurement point.
    These object identifiers indicate a point or location of power
    measurement in…
    1.3.6.1.4.1.476.1.42.3.5.2.3.1.4 lgpPwrLineMeasurementVoltsLL 0 0 The present Line-to-Line voltage measurement for the indicated
    source. The line being measured is given by the
    lgpPwrLineMeasurem…
    1.3.6.1.4.1.476.1.42.3.5.2.3.1.5 lgpPwrLineMeasurementVoltsLN 0 0 The present Line-to-neutral voltage measurement for the indicated
    source. The line being measured is given by the
    lgpPwrLineMeasu…
    1.3.6.1.4.1.476.1.42.3.5.2.3.1.6 lgpPwrLineMeasurementCurrent 0 0 The present current measurement for the indicated source. The line
    being measured is given by the 'lgpPwrLineMeasurementIndex' w…
    1.3.6.1.4.1.476.1.42.3.5.2.3.1.7 lgpPwrLineMeasurementCapacity 0 0 The percentage of the power capacity presently being used on this
    line.
    1.3.6.1.4.1.476.1.42.3.5.2.3.1.8 lgpPwrLineMeasurementVA 0 0 The present apparent AC line power.
    1.3.6.1.4.1.476.1.42.3.5.2.3.1.9 lgpPwrLineMeasurementTruePower 0 0 The present AC line power measured in watts.
    1.3.6.1.4.1.476.1.42.3.5.2.3.1.10 lgpPwrLineMeasurementVoltageTHD 0 0 The present total harmonic distortion on the AC line voltage.
    1.3.6.1.4.1.476.1.42.3.5.2.3.1.11 lgpPwrLineMeasurementCurrentTHD 0 0 The present total harmonic distortion on the AC line current.
    1.3.6.1.4.1.476.1.42.3.5.2.3.1.12 lgpPwrLineMeasurementKFactorCurrent 0 0 The present line K Factor.
    1.3.6.1.4.1.476.1.42.3.5.2.3.1.13 lgpPwrLineMeasurementCrestFactorCurrent 0 0 The present crest factor of the line current.
    1.3.6.1.4.1.476.1.42.3.5.2.3.1.14 lgpPwrLineMeasurementPowerFactor 0 0 The present Power Factor for the line.
    1.3.6.1.4.1.476.1.42.3.5.2.3.1.16 lgpPwrLineMeasurementMaxVolts 0 0 The maximum voltage measurement recorded for the indicated source
    since the command 'lgpPwrStatisticsReset' was executed.
    1.3.6.1.4.1.476.1.42.3.5.2.3.1.17 lgpPwrLineMeasurementMinVolts 0 0 The minimum voltage measurement recorded for the
    indicated source since the command 'lgpPwrStatisticsReset' was
    executed.
    1.3.6.1.4.1.476.1.42.3.5.2.3.1.18 lgpPwrLineMeasurementVAR 0 0 The present reactive AC line power of the power source indicated by
    'lgpPwrMeasurementPoint'.
    1.3.6.1.4.1.476.1.42.3.5.2.3.1.19 lgpPwrLineMeasurementPercentLoad 0 0 The present percent load of the AC line power.
    1.3.6.1.4.1.476.1.42.3.5.2.3.1.20 lgpPwrLineMeasurementVolts 0 0 The present voltage measurement for the indicated source.
    1.3.6.1.4.1.476.1.42.3.5.2.3.1.21 lgpPwrLineMeasurementVACapacity 0 0 The percentage of the apparent power capacity presently being
    used on this line.