An OID representing a well known measurement point.
These object identifiers indicate a point or location of power
measurement in a power system. The OID name usually
implies a location of the measurement point such as
'input', 'output', 'bypass', etc.
Parsed from file LIEBERT_GP_POWER.MIB.txt
Company: None
Module: LIEBERT-GP-POWER-MIB
An OID representing a well known measurement point.
These object identifiers indicate a point or location of power
measurement in a power system. The OID name usually
implies a location of the measurement point such as
'input', 'output', 'bypass', etc.
Parsed from file LIEBERT-GP-POWER-MIB.mib
Module: LIEBERT-GP-POWER-MIB
Vendor: Emerson Computer PowerRoger Draper
Module: LIEBERT-GP-POWER-MIB
[Automatically extracted from oidview.com]
lgpPwrMeasurementPoint OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "An OID representing a well known measurement point. These object identifiers indicate a point or location of power measurement in a power system. The OID name usually implies a location of the measurement point such as 'input', 'output', 'bypass', etc." REFERENCE "The object identifiers in this column can be found in the sub-tree 'lgpPwrWellKnownMeasurementPoints' and correspond to the entry in the table lgpPwrMeasurementPointTable." ::= { lgpPwrLineMeasurementEntry 3 }
lgpPwrMeasurementPoint OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "An OID representing a well known measurement point. These object identifiers indicate a point or location of power measurement in a power system. The OID name usually implies a location of the measurement point such as 'input', 'output', 'bypass', etc." REFERENCE "The object identifiers in this column can be found in the sub-tree 'lgpPwrWellKnownMeasurementPoints' and correspond to the entry in the table lgpPwrMeasurementPointTable." ::= { lgpPwrLineMeasurementEntry 3 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.476.1.42.3.5.2.3.1.1 | lgpPwrMeasurementPtIndex | 0 | 0 | This is the index indicating the row of the table 'lgpPwrMeasurementPointTable' for a power measurement point. |
1.3.6.1.4.1.476.1.42.3.5.2.3.1.2 | lgpPwrLineMeasurementIndex | 0 | 0 | This is the index indicating the row of the table 'lgpPwrLineMeasurementTable' for a power measurement point. |
1.3.6.1.4.1.476.1.42.3.5.2.3.1.4 | lgpPwrLineMeasurementVoltsLL | 0 | 0 | The present Line-to-Line voltage measurement for the indicated source. The line being measured is given by the lgpPwrLineMeasurem… |
1.3.6.1.4.1.476.1.42.3.5.2.3.1.5 | lgpPwrLineMeasurementVoltsLN | 0 | 0 | The present Line-to-neutral voltage measurement for the indicated source. The line being measured is given by the lgpPwrLineMeasu… |
1.3.6.1.4.1.476.1.42.3.5.2.3.1.6 | lgpPwrLineMeasurementCurrent | 0 | 0 | The present current measurement for the indicated source. The line being measured is given by the 'lgpPwrLineMeasurementIndex' w… |
1.3.6.1.4.1.476.1.42.3.5.2.3.1.7 | lgpPwrLineMeasurementCapacity | 0 | 0 | The percentage of the power capacity presently being used on this line. |
1.3.6.1.4.1.476.1.42.3.5.2.3.1.8 | lgpPwrLineMeasurementVA | 0 | 0 | The present apparent AC line power. |
1.3.6.1.4.1.476.1.42.3.5.2.3.1.9 | lgpPwrLineMeasurementTruePower | 0 | 0 | The present AC line power measured in watts. |
1.3.6.1.4.1.476.1.42.3.5.2.3.1.10 | lgpPwrLineMeasurementVoltageTHD | 0 | 0 | The present total harmonic distortion on the AC line voltage. |
1.3.6.1.4.1.476.1.42.3.5.2.3.1.11 | lgpPwrLineMeasurementCurrentTHD | 0 | 0 | The present total harmonic distortion on the AC line current. |
1.3.6.1.4.1.476.1.42.3.5.2.3.1.12 | lgpPwrLineMeasurementKFactorCurrent | 0 | 0 | The present line K Factor. |
1.3.6.1.4.1.476.1.42.3.5.2.3.1.13 | lgpPwrLineMeasurementCrestFactorCurrent | 0 | 0 | The present crest factor of the line current. |
1.3.6.1.4.1.476.1.42.3.5.2.3.1.14 | lgpPwrLineMeasurementPowerFactor | 0 | 0 | The present Power Factor for the line. |
1.3.6.1.4.1.476.1.42.3.5.2.3.1.15 | lgpPwrLineMeasurementPowerFactorTag | 0 | 0 | The present description of the Power Factor for the line. If Leading, the load is said to be capacitive and the phase of the cur… |
1.3.6.1.4.1.476.1.42.3.5.2.3.1.16 | lgpPwrLineMeasurementMaxVolts | 0 | 0 | The maximum voltage measurement recorded for the indicated source since the command 'lgpPwrStatisticsReset' was executed. |
1.3.6.1.4.1.476.1.42.3.5.2.3.1.17 | lgpPwrLineMeasurementMinVolts | 0 | 0 | The minimum voltage measurement recorded for the indicated source since the command 'lgpPwrStatisticsReset' was executed. |
1.3.6.1.4.1.476.1.42.3.5.2.3.1.18 | lgpPwrLineMeasurementVAR | 0 | 0 | The present reactive AC line power of the power source indicated by 'lgpPwrMeasurementPoint'. |
1.3.6.1.4.1.476.1.42.3.5.2.3.1.19 | lgpPwrLineMeasurementPercentLoad | 0 | 0 | The present percent load of the AC line power. |
1.3.6.1.4.1.476.1.42.3.5.2.3.1.20 | lgpPwrLineMeasurementVolts | 0 | 0 | The present voltage measurement for the indicated source. |
1.3.6.1.4.1.476.1.42.3.5.2.3.1.21 | lgpPwrLineMeasurementVACapacity | 0 | 0 | The percentage of the apparent power capacity presently being used on this line. |