This sub-tree registers Liebert Power Status object
identifiers. This is the location of power related status information
that does not fit into a more specific category such as the
lgpPwrConversion sub-tree.
Parsed from file LIEBERT_GP_POWER.MIB.txt
Company: None
Module: LIEBERT-GP-POWER-MIB
This sub-tree registers Liebert Power Status object
identifiers. This is the location of power related status information
that does not fit into a more specific category such as the
lgpPwrConversion sub-tree.
Parsed from file LIEBERT-GP-POWER-MIB.mib
Module: LIEBERT-GP-POWER-MIB
Vendor: Emerson Computer PowerRoger Draper
Module: LIEBERT-GP-POWER-MIB
[Automatically extracted from oidview.com]
lgpPwrStatus OBJECT-IDENTITY STATUS current DESCRIPTION "This sub-tree registers Liebert Power Status object identifiers. This is the location of power related status information that does not fit into a more specific category such as the lgpPwrConversion sub-tree." REFERENCE "The registrations for the objects in this sub-tree are defined below in the sub-section titled Liebert Power Status Group" ::= { lgpPower 3 }
lgpPwrStatus OBJECT-IDENTITY STATUS current DESCRIPTION "This sub-tree registers Liebert Power Status object identifiers. This is the location of power related status information that does not fit into a more specific category such as the lgpPwrConversion sub-tree." REFERENCE "The registrations for the objects in this sub-tree are defined below in the sub-section titled Liebert Power Status Group" ::= { lgpPower 3 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.476.1.42.3.5.3.1 | lgpPwrTransferCount | 1 | 1 | Number of times that the output load has been transferred between the available input sources. |
1.3.6.1.4.1.476.1.42.3.5.3.2 | lgpPwrAutoTransferTimer | 1 | 1 | The required wait time between output load auto transfer attempts between available input sources. |
1.3.6.1.4.1.476.1.42.3.5.3.3 | lgpPwrAutoReTransferEnabled | 1 | 1 | The ability to retransfer the output load automatically to the well known measurement source from the 'lgpPwrWellKnownMeasuremen… |
1.3.6.1.4.1.476.1.42.3.5.3.4 | lgpPwrSyncPhaseAngle | 1 | 1 | The phase angle difference of source 1 in relation to source 2. |
1.3.6.1.4.1.476.1.42.3.5.3.5 | lgpPwrParallelSystemOutputToLoadSource | 1 | 1 | The source supporting the parallel system's load. |
1.3.6.1.4.1.476.1.42.3.5.3.6 | lgpPwrDcToDcConverter | 1 | 1 | The state of the DC to DC converter. |
1.3.6.1.4.1.476.1.42.3.5.3.7 | lgpPwrOutputToLoadOnInverter | 1 | 1 | The present source of output power is the Inverter. |
1.3.6.1.4.1.476.1.42.3.5.3.8 | lgpPwrBatteryChargeCompensating | 1 | 1 | The system is adjusting the battery charging algorithm to accommodate for the battery temperature. |
1.3.6.1.4.1.476.1.42.3.5.3.9 | lgpPwrInverterReady | 1 | 1 | The ability of the inverter to support the output load of the system. |
1.3.6.1.4.1.476.1.42.3.5.3.10 | lgpPwrOutputToLoadOnBypass | 1 | 1 | The present source of output power is the Bypass. |
1.3.6.1.4.1.476.1.42.3.5.3.11 | lgpPwrBoost | 1 | 1 | The present state of the boost circuitry |
1.3.6.1.4.1.476.1.42.3.5.3.12 | lgpPwrBuck | 1 | 1 | The present state of the buck circuitry |
1.3.6.1.4.1.476.1.42.3.5.3.13 | lgpPwrShutdownOverTemperature | 1 | 1 | The system has previously shutdown due to an over temperature condition. |
1.3.6.1.4.1.476.1.42.3.5.3.14 | lgpPwrShutdownOverload | 1 | 1 | The system has previously shutdown due to an over load condition. |
1.3.6.1.4.1.476.1.42.3.5.3.15 | lgpPwrShutdownDcBusOverload | 1 | 1 | The system has previously shutdown due to a DC bus over load condition. |
1.3.6.1.4.1.476.1.42.3.5.3.16 | lgpPwrShutdownOutputShort | 1 | 1 | The system has previously shutdown due to an ouput short condition. |
1.3.6.1.4.1.476.1.42.3.5.3.17 | lgpPwrShutdownLineSwap | 1 | 1 | The system has previously shutdown due to a condition where the line and neutral were reversed. |
1.3.6.1.4.1.476.1.42.3.5.3.18 | lgpPwrShutdownLowBattery | 1 | 1 | The system has previously shutdown due to a low battery condition. |
1.3.6.1.4.1.476.1.42.3.5.3.19 | lgpPwrShutdownRemote | 1 | 1 | The system has previously shutdown due to a remote shutdown command. |
1.3.6.1.4.1.476.1.42.3.5.3.20 | lgpPwrShutdownInputUnderVoltage | 1 | 1 | The system has previously shutdown due to an under voltage condition during startup. |
1.3.6.1.4.1.476.1.42.3.5.3.21 | lgpPwrShutdownPowerFactorCorrectionFailure | 1 | 1 | The system has previously shutdown due to a power factor correction startup failure. |
1.3.6.1.4.1.476.1.42.3.5.3.22 | lgpPwrShutdownHardware | 1 | 1 | The system has previously shutdown due external shutdown signal. |
1.3.6.1.4.1.476.1.42.3.5.3.23 | lgpPwrRedundantSubModule | 1 | 1 | The system has a redundant battery module installed. |
1.3.6.1.4.1.476.1.42.3.5.3.24 | lgpPwrBypassReady | 1 | 1 | The ability of the bypass to support the output load of the system. If Yes, the bypass is available to transfer to. |
1.3.6.1.4.1.476.1.42.3.5.3.25 | lgpPwrGeneratorStatus | 1 | 1 | The state of the system generator. |
1.3.6.1.4.1.476.1.42.3.5.3.26 | lgpPwrRotaryBreakerStatus | 1 | 1 | The state of the system rotary breaker. |
1.3.6.1.4.1.476.1.42.3.5.3.27 | lgpPwrPowerFactorCorrection | 1 | 1 | The state of the power factor correction circuitry of the system. |
1.3.6.1.4.1.476.1.42.3.5.3.28 | lgpPwrBypassSyncDiff | 1 | 1 | The phase angle difference between the inverter output and bypass source. A positive value means the inverter leads the bypass s… |
1.3.6.1.4.1.476.1.42.3.5.3.29 | lgpPwrBypassOverloadShutdownTime | 1 | 1 | The calculated time remaining before bypass static switch shutdown due to the present overload condition. If the bypass is not i… |
1.3.6.1.4.1.476.1.42.3.5.3.30 | lgpPwrInverterOverloadShutdownTime | 1 | 1 | The calculated time remaining before inverter shutdown. The calculated time of inverter operation remaining for the present over… |
1.3.6.1.4.1.476.1.42.3.5.3.31 | lgpPwrStateOutputSource | 1 | 1 | The UPS's output power source (inverter, bypass, or none). NOTE: It is possible that the load still has power from the Maintenanc… |
1.3.6.1.4.1.476.1.42.3.5.3.32 | lgpPwrStateInputSource | 1 | 1 | The system input power source (none, utility, generator). |
1.3.6.1.4.1.476.1.42.3.5.3.33 | lgpPwrStateInputQualification | 1 | 1 | The current state of the system input. The unit may or may not operate normally under 'marginalLow' and 'marginalHigh' states. |
1.3.6.1.4.1.476.1.42.3.5.3.34 | lgpPwrStateBypassStaticSwitchState | 1 | 1 | The current state of the bypass static switch. |
1.3.6.1.4.1.476.1.42.3.5.3.35 | lgpPwrStateBypassQualification | 1 | 1 | The current operational state of the bypass static switch. The unit may or may not operate normally under 'marginalLow' and 'mar… |
1.3.6.1.4.1.476.1.42.3.5.3.36 | lgpPwrStateDCBusQualification | 1 | 1 | The current operational state of the DC bus. The unit may or may not operate normally under 'marginalLow' and 'marginalHigh' sta… |
1.3.6.1.4.1.476.1.42.3.5.3.37 | lgpPwrStateOutQualification | 1 | 1 | The current operational state of the output. The unit may or may not operate normally under 'marginalLow' and 'marginalHigh' sta… |
1.3.6.1.4.1.476.1.42.3.5.3.38 | lgpPwrStateInverterQualification | 1 | 1 | The current operational state of the inverter. The unit may or may not operate normally under 'marginalLow' and 'marginalHigh' s… |
1.3.6.1.4.1.476.1.42.3.5.3.39 | lgpPwrStateInverterState | 1 | 1 | The current state of the inverter. |
1.3.6.1.4.1.476.1.42.3.5.3.40 | lgpPwrStateRectifierState | 1 | 1 | The current state of the rectifier. |
1.3.6.1.4.1.476.1.42.3.5.3.41 | lgpPwrStateModuleGroup | 2 | 4 | This group contains UPS module information. |
1.3.6.1.4.1.476.1.42.3.5.3.42 | lgpPwrStateBackfeedBrkrState | 1 | 1 | The state of the Static Bypass Switch Line Disconnect Breaker. |
1.3.6.1.4.1.476.1.42.3.5.3.43 | lgpPwrStateLoadDisconnectState | 1 | 1 | The state of the Static Bypass Switch Load Disconnect Breaker. |
1.3.6.1.4.1.476.1.42.3.5.3.44 | lgpPwrStateInputBrkrState | 1 | 1 | The state of the Input Disconnect Breaker. |
1.3.6.1.4.1.476.1.42.3.5.3.45 | lgpPwrStateTrapFilterBrkrState | 1 | 1 | The state of the Trap Filter Disconnect Breaker. |
1.3.6.1.4.1.476.1.42.3.5.3.46 | lgpPwrStateInvOutputBrkrState | 1 | 1 | The state of the Inverter Output Disconnect Breaker. |
1.3.6.1.4.1.476.1.42.3.5.3.47 | lgpPwrStateIntBypassBrkrState | 1 | 1 | The state of the Internal Bypass Breaker. |
1.3.6.1.4.1.476.1.42.3.5.3.48 | lgpPwrStateBypassIsolBrkrState | 1 | 1 | The state of the Bypass Isolation Breaker. |
1.3.6.1.4.1.476.1.42.3.5.3.49 | lgpPwrStateRectifierIsolBrkrState | 1 | 1 | The state of the Rectifier Isolation Breaker. |
1.3.6.1.4.1.476.1.42.3.5.3.50 | lgpPwrStateMaintBypassBrkrState | 1 | 1 | The state of the Maintenance Bypass Breaker. |
1.3.6.1.4.1.476.1.42.3.5.3.51 | lgpPwrStateMaintIsolBrkrState | 1 | 1 | The state of the Maintenance Isolation Breaker. |
1.3.6.1.4.1.476.1.42.3.5.3.52 | lgpPwrStateOutStaticSwState | 1 | 1 | The state of the Output Series Static Switch. |
1.3.6.1.4.1.476.1.42.3.5.3.53 | lgpPwrStateModuleOutBrkrState | 1 | 1 | The state of the Module Output Breaker. |
1.3.6.1.4.1.476.1.42.3.5.3.54 | lgpPwrBypassReXfrRemainTime | 1 | 1 | The time remaining before an inverter overload or inverter fault can be cleared and auto retransfer from the bypass to the inver… |
1.3.6.1.4.1.476.1.42.3.5.3.55 | lgpPwrStateUpsOutputSource | 1 | 1 | The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no … |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.476.1.42.3.5.1 | lgpPwrBattery | 26 | 61 | This sub-tree is used to register Liebert Power Battery object identifiers. |
1.3.6.1.4.1.476.1.42.3.5.2 | lgpPwrMeasurements | 5 | 66 | This sub-tree registers Liebert Power Measurement object identifiers. The sub-tree contains tables and well known power measurem… |
1.3.6.1.4.1.476.1.42.3.5.4 | lgpPwrSettings | 20 | 48 | This sub-tree registers Liebert Power Static Switch object identifiers. |
1.3.6.1.4.1.476.1.42.3.5.5 | lgpPwrConversion | 6 | 12 | This sub-tree is used to register Liebert Power Conversion object identifiers. |
1.3.6.1.4.1.476.1.42.3.5.6 | lgpPwrControl | 10 | 24 | This sub-tree is used to register Liebert Power Control object identifiers. |
1.3.6.1.4.1.476.1.42.3.5.7 | lgpPwrTopology | 15 | 30 | This sub-tree is used to register Liebert Power Topology object identifiers. |
1.3.6.1.4.1.476.1.42.3.5.8 | lgpPwrStatistic | 9 | 18 | This sub-tree is used to register Liebert Power Statistic object identifiers. |
1.3.6.1.4.1.476.1.42.3.5.9 | lgpPwrConfig | 4 | 8 | This sub-tree is used to register Liebert Power Config object identifiers. |