Output wire physical wiring configuration.
singlePhase2WireL1WithReturn
Single phase output with 2 wires (Line 1, and Return).
twoPhase2WireL1L2
Two phase output with 2 wires (Line 1, and Line 2).
twoPhase3WireL1L2WithNeutral
Two phase output with 3 wires (Line 1, Line 2, and Neutral)
threePhase3WireL1L2L3
Three phase output with 3 wires (Line 1, Line 2, and Line 3)
threePhase4WireL1L2L3WithNeutral
Three phase output with 4 wires (Line 1, Line 2, Line 3, and
Neutral).
Parsed from file LIEBERT_GP_POWER.MIB.txt
Company: liebert
Module: LIEBERT-GP-POWER-MIB
Child arc 0 is used to translate between SNMPv1 and SNMPv2 notification parameters as explained in IETF RFC 2576, section 3.
lgpPwrStateOutputConfig OBJECT-TYPE SYNTAX INTEGER { singlePhase2WireL1WithReturn(1), twoPhase2WireL1L2(2), twoPhase3WireL1L2WithNeutral(3), threePhase3WireL1L2L3(4), threePhase4WireL1L2L3WithNeutral(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Output wire physical wiring configuration. singlePhase2WireL1WithReturn Single phase output with 2 wires (Line 1, and Return). twoPhase2WireL1L2 Two phase output with 2 wires (Line 1, and Line 2). twoPhase3WireL1L2WithNeutral Two phase output with 3 wires (Line 1, Line 2, and Neutral) threePhase3WireL1L2L3 Three phase output with 3 wires (Line 1, Line 2, and Line 3) threePhase4WireL1L2L3WithNeutral Three phase output with 4 wires (Line 1, Line 2, Line 3, and Neutral)." ::= { lgpPwrTopology 12 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.476.1.42.3.5.7.12.0 | lgpPwrStateOutputConfig | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.476.1.42.3.5.7.1 | lgpPwrUpsTopOffline | 1 | 1 | The UPS has a offline topology. Under normal operating conditions, AC power from the utility passes straight through the UPS to … |
1.3.6.1.4.1.476.1.42.3.5.7.2 | lgpPwrUpsTopLineInteractive | 1 | 1 | The UPS has a line-interactive topology. This topology resembles the offline product, but inserts a transformer or inductor in s… |
1.3.6.1.4.1.476.1.42.3.5.7.3 | lgpPwrUPSTopDualInput | 1 | 1 | The system has separate input sources for the bypass and inverter. |
1.3.6.1.4.1.476.1.42.3.5.7.4 | lgpPwrTopFrequencyConverter | 1 | 1 | The system has a freqency converter. |
1.3.6.1.4.1.476.1.42.3.5.7.5 | lgpPwrTopVoltageConverter | 1 | 1 | The system has a voltage converter. |
1.3.6.1.4.1.476.1.42.3.5.7.6 | lgpPwrTopMaximumFrameCapacity | 1 | 1 | The maximum device system capacity. |
1.3.6.1.4.1.476.1.42.3.5.7.7 | lgpPwrTopRedundantControlModules | 1 | 1 | The device has a redundant control module installed. |
1.3.6.1.4.1.476.1.42.3.5.7.8 | lgpPwrInputIsolationTransformerInstalled | 1 | 1 | Indicates whether the input isolation transformer is installed. |
1.3.6.1.4.1.476.1.42.3.5.7.9 | lgpPwrStateStaticSwitchType | 1 | 1 | lgpPwrStateStaticSwitchtype |
1.3.6.1.4.1.476.1.42.3.5.7.10 | lgpPwrStateModuleType | 1 | 1 | None |
1.3.6.1.4.1.476.1.42.3.5.7.11 | lgpPwrStateBypassInputConfig | 1 | 1 | Bypass input wire physical wiring configuration. singlePhase2WireL1WithReturn Single phase input with 2 wires (Line 1, and Return… |
1.3.6.1.4.1.476.1.42.3.5.7.13 | lgpPwrRectifierPassiveFilterInstalled | 1 | 1 | Indicates whether the rectifier passive filter is installed. |
1.3.6.1.4.1.476.1.42.3.5.7.14 | lgpPwrRectifierTrapInstalled | 1 | 1 | Indicates whether the rectifier input passive filter is installed. |
1.3.6.1.4.1.476.1.42.3.5.7.15 | lgpPwrRectifierActiveFilterInstalled | 1 | 1 | Indicates whether the rectifier active filter is installed. |