The system has separate input sources for the bypass and inverter.
Parsed from file LIEBERT_GP_POWER.MIB.txt
Company: None
Module: LIEBERT-GP-POWER-MIB
The system has separate input sources for the bypass and inverter.
Parsed from file LIEBERT-GP-POWER-MIB.mib
Module: LIEBERT-GP-POWER-MIB
Vendor: Emerson Computer PowerRoger Draper
Module: LIEBERT-GP-POWER-MIB
[Automatically extracted from oidview.com]
lgpPwrUPSTopDualInput OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The system has separate input sources for the bypass and inverter." ::= { lgpPwrTopology 3 }
lgpPwrUPSTopDualInput OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2)} MAX-ACCESS read-only STATUS current DESCRIPTION "The system has separate input sources for the bypass and inverter." ::= { lgpPwrTopology 3 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.476.1.42.3.5.7.3.0 | lgpPwrUPSTopDualInput | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.476.1.42.3.5.7.1 | lgpPwrUpsTopOffline | 1 | 1 | The UPS has a offline topology. Under normal operating conditions, AC power from the utility passes straight through the UPS to … |
1.3.6.1.4.1.476.1.42.3.5.7.2 | lgpPwrUpsTopLineInteractive | 1 | 1 | The UPS has a line-interactive topology. This topology resembles the offline product, but inserts a transformer or inductor in s… |
1.3.6.1.4.1.476.1.42.3.5.7.4 | lgpPwrTopFrequencyConverter | 1 | 1 | The system has a freqency converter. |
1.3.6.1.4.1.476.1.42.3.5.7.5 | lgpPwrTopVoltageConverter | 1 | 1 | The system has a voltage converter. |
1.3.6.1.4.1.476.1.42.3.5.7.6 | lgpPwrTopMaximumFrameCapacity | 1 | 1 | The maximum device system capacity. |
1.3.6.1.4.1.476.1.42.3.5.7.7 | lgpPwrTopRedundantControlModules | 1 | 1 | The device has a redundant control module installed. |
1.3.6.1.4.1.476.1.42.3.5.7.8 | lgpPwrInputIsolationTransformerInstalled | 1 | 1 | Indicates whether the input isolation transformer is installed. |
1.3.6.1.4.1.476.1.42.3.5.7.9 | lgpPwrStateStaticSwitchType | 1 | 1 | lgpPwrStateStaticSwitchtype |
1.3.6.1.4.1.476.1.42.3.5.7.10 | lgpPwrStateModuleType | 1 | 1 | None |
1.3.6.1.4.1.476.1.42.3.5.7.11 | lgpPwrStateBypassInputConfig | 1 | 1 | Bypass input wire physical wiring configuration. singlePhase2WireL1WithReturn Single phase input with 2 wires (Line 1, and Return… |
1.3.6.1.4.1.476.1.42.3.5.7.12 | lgpPwrStateOutputConfig | 1 | 1 | Output wire physical wiring configuration. singlePhase2WireL1WithReturn Single phase output with 2 wires (Line 1, and Return). two… |
1.3.6.1.4.1.476.1.42.3.5.7.13 | lgpPwrRectifierPassiveFilterInstalled | 1 | 1 | Indicates whether the rectifier passive filter is installed. |
1.3.6.1.4.1.476.1.42.3.5.7.14 | lgpPwrRectifierTrapInstalled | 1 | 1 | Indicates whether the rectifier input passive filter is installed. |
1.3.6.1.4.1.476.1.42.3.5.7.15 | lgpPwrRectifierActiveFilterInstalled | 1 | 1 | Indicates whether the rectifier active filter is installed. |