Displays the state of the NTP on the system clock. Clock states are:
0 - Clock has never been calibrated for frequency errors
1 - Clock frequency errors calibration has done
2 - Clock time has set to server time
3 - Clock frequency errors calibration is going on
4 - Clock has synchronized its time
5 - Clock has detected spike
Parsed from file juniSystemClock.mi2.txt
Company: None
Module: Juniper-System-Clock-MIB
Displays the state of the NTP on the system clock. Clock states are:
0 - Clock has never been calibrated for frequency errors
1 - Clock frequency errors calibration has done
2 - Clock time has set to server time
3 - Clock frequency errors calibration is going on
4 - Clock has synchronized its time
5 - Clock has detected spike
Parsed from file Unisphere-Data-System-Clock-MIB.mib
Module: Unisphere-Data-System-Clock-MIB
Vendor: Juniper Networks/Unisphere
Module: Juniper-System-Clock-MIB
[Automatically extracted from oidview.com]
juniNtpSysClockState OBJECT-TYPE SYNTAX INTEGER { neverFrequencyCalibrated(0), frequencyCalibrated(1), setToServerTime(2), frequencyCalibrationIsGoingOn(3), synchronized(4), spikeDetected(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Displays the state of the NTP on the system clock. Clock states are: 0 - Clock has never been calibrated for frequency errors 1 - Clock frequency errors calibration has done 2 - Clock time has set to server time 3 - Clock frequency errors calibration is going on 4 - Clock has synchronized its time 5 - Clock has detected spike " REFERENCE "D.L. Mills, 'Network Time Protocol (Version 3)', RFC-1305, March 1992" ::= { juniNtpSysClock 1 }
usdNtpSysClockState OBJECT-TYPE SYNTAX INTEGER { neverFrequencyCalibrated(0), frequencyCalibrated(1), setToServerTime(2), frequencyCalibrationIsGoingOn(3), synchronized(4), spikeDetected(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Displays the state of the NTP on the system clock. Clock states are: 0 - Clock has never been calibrated for frequency errors 1 - Clock frequency errors calibration has done 2 - Clock time has set to server time 3 - Clock frequency errors calibration is going on 4 - Clock has synchronized its time 5 - Clock has detected spike " REFERENCE "D.L. Mills, 'Network Time Protocol (Version 3)', RFC-1305, March 1992" ::= { usdNtpSysClock 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.4874.2.2.56.2.1.1.0 | juniNtpSysClockState | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.4874.2.2.56.2.1.2 | juniNtpSysClockOffsetError, usdNtpSysClockOffsetError | 1 | 1 | Displays the estimated offset error of the system clock relative to the master clock in seconds. This variable can take on both… |
1.3.6.1.4.1.4874.2.2.56.2.1.3 | juniNtpSysClockFrequencyError, usdNtpSysClockFrequencyError | 1 | 1 | Displays the system clock frequency error in parts per million (ppm). It will always be a positive value. This error adjustment… |
1.3.6.1.4.1.4874.2.2.56.2.1.4 | juniNtpSysClockRootDelay, usdNtpSysClockRootDelay | 1 | 1 | This indicates the NTP time message total Network roundtrip delay to the primary reference source at the root of the synchroniza… |
1.3.6.1.4.1.4874.2.2.56.2.1.5 | juniNtpSysClockRootDispersion, usdNtpSysClockRootDispersion | 1 | 1 | This indicates the maximum error relative to the primary reference source at the root of the synchronization subnet, in seconds.… |
1.3.6.1.4.1.4874.2.2.56.2.1.6 | juniNtpSysClockStratumNumber, usdNtpSysClockStratumNumber | 1 | 1 | Displays the stratum number of the system clock. 1 - primary reference (e.g. calibrated atomic clock, radio clock) 2-255 - seco… |
1.3.6.1.4.1.4874.2.2.56.2.1.7 | juniNtpSysClockLastUpdateTime, usdNtpSysClockLastUpdateTime | 1 | 1 | Displays the time of the system clock at the time when it was last updated by any associated NTP server(peer). |
1.3.6.1.4.1.4874.2.2.56.2.1.8 | juniNtpSysClockLastUpdateServer, usdNtpSysClockLastUpdateServer | 1 | 1 | Displays the IP address of the NTP server (peer) which done last update to the system clock. |
1.3.6.1.4.1.4874.2.2.56.2.1.9 | juniNtpSysClockOffsetErrorNew | 1 | 1 | Displays the estimated offset error of the system clock relative to the master clock in seconds. This variable can take on both… |
1.3.6.1.4.1.4874.2.2.56.2.1.10 | juniNtpSysClockFrequencyErrorNew | 1 | 1 | Displays the system clock frequency error in parts per million (ppm). It will always be a positive value. This error adjustment… |