Determines the textual name of the destination service this route
connects to. When attempting a X25 connection across Frame Relay, this
object specifies the name of the outgoing circuit at the Frame Relay
layer.
When attempting a X25 connection between cards within the same chassis
(future use within CX1000), this object specifies the name of the X25
Convergence SAP on the remote card.
Range of Values: 1 -16 characters (first character must be a letter)
Default Value: none
Configuration Changed: administrative and operative
Parsed from file CXGIM.MIB.txt
Company: None
Module: CXGIM-MIB
Determines the textual name of the destination service this route
connects to. When attempting a X25 connection across Frame Relay, this
object specifies the name of the outgoing circuit at the Frame Relay
layer.
When attempting a X25 connection between cards within the same chassis
(future use within CX1000), this object specifies the name of the X25
Convergence SAP on the remote card.
Range of Values: 1 -16 characters (first character must be a letter)
Default Value: none
Configuration Changed: administrative and operative
Parsed from file CXGIM-MIB.mib
Module: CXGIM-MIB
Vendor: Memotec Communications
Module: CXGIM-MIB
[Automatically extracted from oidview.com]
gimSRDestAlias OBJECT-TYPE SYNTAX Alias ACCESS read-write STATUS mandatory DESCRIPTION "Determines the textual name of the destination service this route connects to. When attempting a X25 connection across Frame Relay, this object specifies the name of the outgoing circuit at the Frame Relay layer. When attempting a X25 connection between cards within the same chassis (future use within CX1000), this object specifies the name of the X25 Convergence SAP on the remote card. Range of Values: 1 -16 characters (first character must be a letter) Default Value: none Configuration Changed: administrative and operative" ::= { gimSysRouteEntry 4 }
gimSRDestAlias OBJECT-TYPE SYNTAX Alias ACCESS read-write STATUS mandatory DESCRIPTION "Determines the textual name of the destination service this route connects to. When attempting a X25 connection across Frame Relay, this object specifies the name of the outgoing circuit at the Frame Relay layer. When attempting a X25 connection between cards within the same chassis (future use within CX1000), this object specifies the name of the X25 Convergence SAP on the remote card. Range of Values: 1 -16 characters (first character must be a letter) Default Value: none Configuration Changed: administrative and operative" ::= { gimSysRouteEntry 4 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.495.2.1.6.55.11.1.1 | gimSRSapType | 0 | 0 | Identifies the type of service access point this route entry is associated with. |
1.3.6.1.4.1.495.2.1.6.55.11.1.2 | gimSRSapNumber | 0 | 0 | Identifies the service access point this route entry is associated with. |
1.3.6.1.4.1.495.2.1.6.55.11.1.3 | gimSRRowStatus | 0 | 0 | Determines the status of the objects in a table row. Options: invalid (1): Row is deleted from the table immediately, however val… |
1.3.6.1.4.1.495.2.1.6.55.11.1.5 | gimSRSubRef | 0 | 0 | Specifies a reference number that uniquely identifies this route. This number is used by the FRIM (Frame Relay Interface Module)… |
1.3.6.1.4.1.495.2.1.6.55.11.1.10 | gimSRRouteStatus | 0 | 0 | Indicates the connection status of this X25 route. Options: offLine (1): Indicates that the X25 Convergence SAP this route is asso… |
1.3.6.1.4.1.495.2.1.6.55.11.1.11 | gimSRClearStatus | 0 | 0 | Indicates the status of a failed connection. The value of this object is only valid only between attempts to establish the route… |