This variable is used to report the elapsed system tick
time for conversion to real time at the controller and is
not related to the sysUpTime referenced in MIB-II.
Upon power-up of the unit, the elapsed time is cleared.
The elapsed time counter rolls over upon reaching the
maximum count.
SCinstance: [L]ine=5 [i]nterface=0
Parsed from file gdc7624.mib.txt
Company: None
Module: GDCUAS7624-MIB
This variable is used to report the elapsed system tick
time for conversion to real time at the controller and is
not related to the sysUpTime referenced in MIB-II.
Upon power-up of the unit, the elapsed time is cleared.
The elapsed time counter rolls over upon reaching the
maximum count.
SCinstance: [L]ine=5 [i]nterface=0
Parsed from file GDCUAS7624-MIB.mib
Module: GDCUAS7624-MIB
uas7624SysUpTime OBJECT-TYPE SYNTAX INTEGER (1..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used to report the elapsed system tick time for conversion to real time at the controller and is not related to the sysUpTime referenced in MIB-II. Upon power-up of the unit, the elapsed time is cleared. The elapsed time counter rolls over upon reaching the maximum count. SCinstance: [L]ine=5 [i]nterface=0" ::= { uas7624MaintenanceEntry 9 }
Vendor: General DataComm, Inc.
Module: GDCUAS7624-MIB
[Automatically extracted from oidview.com]
uas7624SysUpTime OBJECT-TYPE SYNTAX INTEGER (1..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "This variable is used to report the elapsed system tick time for conversion to real time at the controller and is not related to the sysUpTime referenced in MIB-II. Upon power-up of the unit, the elapsed time is cleared. The elapsed time counter rolls over upon reaching the maximum count. SCinstance: [L]ine=5 [i]nterface=0" ::= { uas7624MaintenanceEntry 9 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.498.18.1.2.1.1.1 | uas7624MaintenanceLineIndex | 0 | 0 | Integer value which uniquely identifies the uas7624 to which this entry is applicable. See DESCRIPTION's below for ranges. |
1.3.6.1.4.1.498.18.1.2.1.1.2 | uas7624SoftReset | 0 | 0 | Supports the action of soft resetting the unit. When this object is set to reset(2), then the unit performs a soft reset, whose m… |
1.3.6.1.4.1.498.18.1.2.1.1.3 | uas7624DefaultInit | 0 | 0 | This is used to allow the NonVolatile Configuration to be set to a factory default state. When this value is set to factoryDefau… |
1.3.6.1.4.1.498.18.1.2.1.1.4 | uas7624ResetMajorAlarm | 0 | 0 | This variable is used. SCinstance: [L]ine=1-4 [i]nterface=1-3 |
1.3.6.1.4.1.498.18.1.2.1.1.5 | uas7624ResetMinorAlarm | 0 | 0 | This variable is used. SCinstance: [L]ine=1-4 [i]nterface=1-3 |
1.3.6.1.4.1.498.18.1.2.1.1.6 | uas7624ResetStatistics | 0 | 0 | This variable is used to reset the performance intervals. When it is set to reset, the performance tables and uas7624Valid interv… |
1.3.6.1.4.1.498.18.1.2.1.1.7 | uas7624StatLastInitialized | 0 | 0 | The elapsed time since the statistics were last initialized. This will be zero'd when uas7624ResetStatistics is reset(2). SCinsta… |
1.3.6.1.4.1.498.18.1.2.1.1.8 | uas7624ValidIntervals | 0 | 0 | The number of previous intervals for which valid data was collected. The value will be 96 for the T1 interface and 16 for th… |
1.3.6.1.4.1.498.18.1.2.1.1.10 | uas7624LedStatus | 0 | 0 | Returns a bitwise snapshot of the front panel LED state. based on the Line: For SCinstance: [L]ine=1-4 [i]nterface=0 key 01 = S… |
1.3.6.1.4.1.498.18.1.2.1.1.11 | uas7624AlarmStatus | 0 | 0 | Returns a bit-wise Status of alarms with both masked and unmasked. For SCinstance: [L]ine=1-4 [i]nterface=0 1.7 - f/u 1.6 - Powe… |
1.3.6.1.4.1.498.18.1.2.1.1.12 | uas7624LoopState | 0 | 0 | A setting of inhibit(1) stops operation on the loop and a setting of enable(2) starts operation on the loop. SCinstance: [L]ine=1-… |
1.3.6.1.4.1.498.18.1.2.1.1.13 | uas7624ConfigMode | 0 | 0 | This variable is used to report the mode, either soft or hard, of the the uas7624. If the unit is in hard mode then the options … |