This variable is used to set the Cascade
PreEqualization option for matching the cascade port
line length, providing transmitter pre-equalization for
lengths of 130 ft (0-130 feet), 260 ft (130-260 feet)
390 ft (260-390 feet), 530 ft (390-530 feet) or
655 ft (530-655 feet). Selecting the proper length
ensures that the signal reaching the customer
cascade equipment is satisfactory.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 None
552a PreEqualization Same as defined in managed object
552a V1.1 PreEqualization Same as defined in managed object
551 PreEqualization Same as defined in managed object
Parsed from file gdcds1.mib.txt
Company: None
Module: GDCDS1-MIB
This variable is used to set the Cascade
PreEqualization option for matching the cascade port
line length, providing transmitter pre-equalization for
lengths of 130 ft (0-130 feet), 260 ft (130-260 feet)
390 ft (260-390 feet), 530 ft (390-530 feet) or
655 ft (530-655 feet). Selecting the proper length
ensures that the signal reaching the customer
cascade equipment is satisfactory.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 None
552a PreEqualization Same as defined in managed object
552a V1.1 PreEqualization Same as defined in managed object
551 PreEqualization Same as defined in managed object
Parsed from file GDCDS1-MIB.mib
Module: GDCDS1-MIB
csuPreEqualizer OBJECT-TYPE SYNTAX INTEGER { csuNoEqual(1), csu130ft(2), csu260ft(3), csu390ft(4), csu530ft(5), csu655ft(6) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used to set the Cascade PreEqualization option for matching the cascade port line length, providing transmitter pre-equalization for lengths of 130 ft (0-130 feet), 260 ft (130-260 feet) 390 ft (260-390 feet), 530 ft (390-530 feet) or 655 ft (530-655 feet). Selecting the proper length ensures that the signal reaching the customer cascade equipment is satisfactory. GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS 552a-1 None 552a PreEqualization Same as defined in managed object 552a V1.1 PreEqualization Same as defined in managed object 551 PreEqualization Same as defined in managed object" ::= { csuConfigEntry 10 }
Vendor: General DataComm, Inc.
Module: GDCDS1-MIB
[Automatically extracted from oidview.com]
csuPreEqualizer OBJECT-TYPE SYNTAX INTEGER { csuNoEqual(1), csu130ft(2), csu260ft(3), csu390ft(4), csu530ft(5), csu655ft(6) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable is used to set the Cascade PreEqualization option for matching the cascade port line length, providing transmitter pre-equalization for lengths of 130 ft (0-130 feet), 260 ft (130-260 feet) 390 ft (260-390 feet), 530 ft (390-530 feet) or 655 ft (530-655 feet). Selecting the proper length ensures that the signal reaching the customer cascade equipment is satisfactory. GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS 552a-1 None 552a PreEqualization Same as defined in managed object 552a V1.1 PreEqualization Same as defined in managed object 551 PreEqualization Same as defined in managed object" ::= { csuConfigEntry 10 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.498.2.1.1.1 | csuConfigLineIndex | 0 | 0 | This object is the identifier of a DS1 interface on a managed object. It is used to associate the DS1 Configuration Group in the … |
1.3.6.1.4.1.498.2.1.1.2 | csuOnesDensity | 0 | 0 | This variable is used to indicate the pulse density on the network side. inhibit refers to no minimum pulse density csuMax15Zeros … |
1.3.6.1.4.1.498.2.1.1.3 | csuFrontPanel | 0 | 0 | This variable is used to indicate whether the front panel switches are operational or not. inhibit refers to when the front panel… |
1.3.6.1.4.1.498.2.1.1.4 | csuInbandLoop | 0 | 0 | This variable is used to set the In-Band DS1 Loopback Code Detection. inhibit refers to when the in-band loopback codes are ignore… |
1.3.6.1.4.1.498.2.1.1.5 | csuILBFrame | 0 | 0 | This variable is used to set the In-Band DS1 Loopback Code Framing option. unframed refers to the DSU transmitting unframed in-ba… |
1.3.6.1.4.1.498.2.1.1.6 | csuLineBuildOutCtrl | 0 | 0 | This variable is used to set the Network Line Build-Out control option for the network side. Man refers to manually setting the N… |
1.3.6.1.4.1.498.2.1.1.7 | csuLineBuildOutValue | 0 | 0 | This variable is used to set the Network Line Build-Out value on the network side. In manual mode, these values can be written an… |
1.3.6.1.4.1.498.2.1.1.8 | csuLineTypeCtrl | 0 | 0 | This variable is used to set the Line Type control. None refers to the unframed mode of the DC551. Man refers to manually setting … |
1.3.6.1.4.1.498.2.1.1.9 | csuAISLoopdown | 0 | 0 | This variable is used to set the AIS Loop-Down option for remotely-initiated DS1 loopbacks. 4, inhibit, refers to when a continuo… |
1.3.6.1.4.1.498.2.1.1.11 | csuInitialize | 0 | 0 | This variable is used to initialize specific items on the csu, csuAlarmHistory refers to initializing the Alarm History Report and… |
1.3.6.1.4.1.498.2.1.1.12 | csuTime | 0 | 0 | This variable is used to set the time for the real-time clock located on the network element. The string is fixed at a length of … |
1.3.6.1.4.1.498.2.1.1.13 | csuDate | 0 | 0 | This variable is used to set the date for the real-time clock located on the network element. The string is fixed at a length of … |
1.3.6.1.4.1.498.2.1.1.14 | csuTestType | 0 | 0 | This variable is used to set the network side DS1 loop type. If csuLLB is set, a line loop is done when the proper inband loop p… |
1.3.6.1.4.1.498.2.1.1.15 | csuReceiveLevel | 0 | 0 | This variable is used to display the current receive level as reported by the Receive Level screen. GDCPRODUCT EQUIVALENT POSSIBL… |