Supports the action of soft resetting the uas7022FarEndValidIntervals
object. When this object is set to reset(2), then the unit
will reset the uas7022FarEndValidIntervals object to zero.
The value of norm(1) can not be set by management.
Valid [i]nterface = 1-2
Parsed from file gdc7022.mib.txt
Company: None
Module: GDCUAS7022-MIB
Supports the action of soft resetting the uas7022FarEndValidIntervals
object. When this object is set to reset(2), then the unit
will reset the uas7022FarEndValidIntervals object to zero.
The value of norm(1) can not be set by management.
Valid [i]nterface = 1-2
Parsed from file GDCUAS7022-MIB.mib
Module: GDCUAS7022-MIB
uas7022FarEndResetStats OBJECT-TYPE SYNTAX INTEGER { norm(1), reset(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Supports the action of soft resetting the uas7022FarEndValidIntervals object. When this object is set to reset(2), then the unit will reset the uas7022FarEndValidIntervals object to zero. The value of norm(1) can not be set by management. Valid [i]nterface = 1-2" ::= { uas7022MaintenanceEntry 8 }
Vendor: General DataComm, Inc.
Module: GDCUAS7022-MIB
[Automatically extracted from oidview.com]
uas7022FarEndResetStats OBJECT-TYPE SYNTAX INTEGER { norm(1), reset(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Supports the action of soft resetting the uas7022FarEndValidIntervals object. When this object is set to reset(2), then the unit will reset the uas7022FarEndValidIntervals object to zero. The value of norm(1) can not be set by management. Valid [i]nterface = 1-2" ::= { uas7022MaintenanceEntry 8 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.498.6.13.2.1.1.1 | uas7022MaintenanceLineIndex | 0 | 0 | Integer value which uniquely identifies the UAS7022 to which this entry is applicable. SCinstance is defined to be SLDi where: S … |
1.3.6.1.4.1.498.6.13.2.1.1.2 | uas7022SoftReset | 0 | 0 | Supports the action of soft resetting the unit. When this object is set to reset(2), then the unit performs a soft reset, whose … |
1.3.6.1.4.1.498.6.13.2.1.1.3 | uas7022SysUpTime | 0 | 0 | This variable is used to report the elapsed system tick time for conversion to real time at the controller and is not related to … |
1.3.6.1.4.1.498.6.13.2.1.1.4 | uas7022DefaultInit | 0 | 0 | This is used to allow the NonVolatile Configuration to be set to a factory default state. When this value is set to factoryDefau… |
1.3.6.1.4.1.498.6.13.2.1.1.5 | uas7022LedStatus | 0 | 0 | Returns a bitwise snapshot of the front panel LED state. Octet 1 bit 7 - not used bit 6 - future use bit 5 - INSV bit 4 - RSP bit 3 … |
1.3.6.1.4.1.498.6.13.2.1.1.6 | uas7022AlarmStatus | 0 | 0 | Returns a bit-wise Status of alarms Octet 1 bit 7 - not used bit 6 - NIUA_LOS bit 5 - NIUA_LOF bit 4 - NIUA_AIS bit 3 - NIUA_LCV bit … |
1.3.6.1.4.1.498.6.13.2.1.1.7 | uas7022NearEndResetStats | 0 | 0 | Supports the action of soft resetting the uas7022NearEndValidIntervals object. When this object is set to reset(2), then the un… |
1.3.6.1.4.1.498.6.13.2.1.1.9 | uas7022NearEndStatLastInit | 0 | 0 | Number of seconds from midnight Dec 31, 1969 up until uas7022NearEndValidIntervals was last initialized to zero Valid [i]nterface… |
1.3.6.1.4.1.498.6.13.2.1.1.10 | uas7022FarEndStatLastInit | 0 | 0 | Number of seconds from midnight Dec 31, 1969 up until uas7022FarEndValidIntervals was last initialized to zero Valid [i]nterface … |
1.3.6.1.4.1.498.6.13.2.1.1.11 | uas7022NearEndValidIntervals | 0 | 0 | The number of previous intervals for which valid data was collected. The value will be 16 unless the interface was brought o… |
1.3.6.1.4.1.498.6.13.2.1.1.12 | uas7022FarEndValidIntervals | 0 | 0 | The number of previous intervals for which valid data was collected. The value will be 16 unless the interface was brought o… |
1.3.6.1.4.1.498.6.13.2.1.1.13 | uas7022NIUaCircuitID | 0 | 0 | This variable is used for general purpose storage. Valid [i]nterface = 1 |
1.3.6.1.4.1.498.6.13.2.1.1.14 | uas7022SystemTimingGenStatus | 0 | 0 | Indicates if the units configured for primary or secondary system clock are actually supplying clock and if it is the 8hkz, 4mhz,… |
1.3.6.1.4.1.498.6.13.2.1.1.15 | uas7022NIUbCircuitID | 0 | 0 | This variable is used for general purpose storage. Valid [i]nterface = 2 |