with IFP(2) means that the unit has a LCD configurable display.
single-height(1) means that the unit does NOT have a LCD
configurable display.
Parsed from file nms520.mib.txt
Company: None
Module: NMS520-MIB
with IFP(2) means that the unit has a LCD configurable display.
single-height(1) means that the unit does NOT have a LCD
configurable display.
Parsed from file NMS520-MIB.mib
Module: NMS520-MIB
nms520UnitType OBJECT-TYPE SYNTAX INTEGER { singleHeight(1), withIFP(2) } ACCESS read-only STATUS mandatory DESCRIPTION "with IFP(2) means that the unit has a LCD configurable display. single-height(1) means that the unit does NOT have a LCD configurable display." ::= { nms520UnitCfgEntry 17 }
Vendor: General DataComm, Inc.
Module: NMS520-MIB
[Automatically extracted from oidview.com]
nms520UnitType OBJECT-TYPE SYNTAX INTEGER { singleHeight(1), withIFP(2) } ACCESS read-only STATUS mandatory DESCRIPTION "with IFP(2) means that the unit has a LCD configurable display. single-height(1) means that the unit does NOT have a LCD configurable display." ::= { nms520UnitCfgEntry 17 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.498.8.2.2.1.1 | nms520UnitCfgIndex | 0 | 0 | The index value which uniquely identifies the NMS520 to which this entry is applicable. This has the form of a SCinstance which … |
1.3.6.1.4.1.498.8.2.2.1.2 | nms520Nms510CompatibilityMode | 0 | 0 | The NMS510 compatibility mode. This mode allows the NMS520 to behave in a manner compatible with that of the NMS510 in a DDSI mul… |
1.3.6.1.4.1.498.8.2.2.1.3 | nms520PtToPtSentryTime | 0 | 0 | The Point to point sentry time nms520PtToPtSentryTime, is used to control the amount of time between unsolicited alarm responses… |
1.3.6.1.4.1.498.8.2.2.1.4 | nms520AlarmHystTime | 0 | 0 | The Alarm hysterysis time nms520AlarmHystTime, is used to control the amount of time a remote must wait between reporting unsoli… |
1.3.6.1.4.1.498.8.2.2.1.5 | nms520MtpointRmRspIntrvl | 0 | 0 | The multipoint remote response interval nms520MtpointRmRspIntrvl, is used to control the amount of time between unsolicited alar… |
1.3.6.1.4.1.498.8.2.2.1.6 | nms520DtePortType | 0 | 0 | The value auto(3), indicates that the DTE port is automatically being detected, and set. The rs232(1), will force the DTE port to… |
1.3.6.1.4.1.498.8.2.2.1.7 | nms520DteCtsDelay | 0 | 0 | RTS/CTS Delay options ctsOn(1) Forces both RTS and CTS On regardless of the state of the attached business equipment (the transmi… |
1.3.6.1.4.1.498.8.2.2.1.8 | nms520DteCtsDelayExt | 0 | 0 | RTS/CTS Delay options extension ext0mSec(1) Used to enable options cts0mSec(2) or ctsFix3Char(3) from MIB object nms520DteCtsDelay… |
1.3.6.1.4.1.498.8.2.2.1.9 | nms520FirmwareLevel | 0 | 0 | None |
1.3.6.1.4.1.498.8.2.2.1.10 | nms520DaisyChainBps | 0 | 0 | Indicates the data rate at which the management data is sent/received when the gdcNmsManagementSource is daisyChain(4). |
1.3.6.1.4.1.498.8.2.2.1.11 | nms520AlarmCfgCountWindow | 0 | 0 | The DDS Alarm Threshold Alarm Interval. It specifies the amount of time in minutes, 1 to 15 minutes, in which the threshold sett… |
1.3.6.1.4.1.498.8.2.2.1.12 | nms520SoftReset | 0 | 0 | This object will cause software reset in dataset. |
1.3.6.1.4.1.498.8.2.2.1.13 | nms520FrontPanelInhibit | 0 | 0 | Inhibits all front panel test switches. If a test switch is activated while inhibited it will simply be ignored. If enabled via … |
1.3.6.1.4.1.498.8.2.2.1.14 | nms520FrontPanelEnable | 0 | 0 | Enables all front panel test switches. If a test switch is activated while inhibited, via the nms520FrontPanelInhibit object, it… |
1.3.6.1.4.1.498.8.2.2.1.15 | nms520HdlcInvert | 0 | 0 | Primary data invert option. Will enhance the quality of data when network does not provide B8Z5. Primarily used with DDS II 56k |
1.3.6.1.4.1.498.8.2.2.1.16 | nms520PiggyBackDetect | 0 | 0 | If set to 2 then either a Data Rate Adadaptor or 530 card is installed. |
1.3.6.1.4.1.498.8.2.2.1.18 | nms520ExtPortCtrlOut1 | 0 | 0 | This option sets the external output state (on/off) of the current network element and displays the external output. |
1.3.6.1.4.1.498.8.2.2.1.19 | nms520ExtPortCtrlOut2 | 0 | 0 | This option sets the external output state (on/off) of the current network element and displays the external output. |