Maximum backoff time (seconds) to delay between
subsequent attempts to open additional virtual
circuits to the same destination. The actual
delay is varied exponentially from
accX25InitBackoff up to this value.
Parsed from file accX25.my.txt
Company: None
Module: ACC-X25
Maximum backoff time (seconds) to delay between
subsequent attempts to open additional virtual
circuits to the same destination. The actual
delay is varied exponentially from
accX25InitBackoff up to this value.
Parsed from file ACC-X25.mib
Module: ACC-X25
Vendor: ACC
Module: ACC-X25
[Automatically extracted from oidview.com]
accX25MaxBackoff OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " Maximum backoff time (seconds) to delay between subsequent attempts to open additional virtual circuits to the same destination. The actual delay is varied exponentially from accX25InitBackoff up to this value." DEFVAL { 86400 } ::= { accX25PortParmEntry 18 }
accX25MaxBackoff OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION " Maximum backoff time (seconds) to delay between subsequent attempts to open additional virtual circuits to the same destination. The actual delay is varied exponentially from accX25InitBackoff up to this value." DEFVAL { 86400 } ::= { accX25PortParmEntry 18 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.5.1.1.17.3.1.1 | accX25PortParmIndex, sbeX25PortParmIndex | 0 | 0 | Port number |
1.3.6.1.4.1.5.1.1.17.3.1.2 | accX25AddrMode, sbeX25AddrMode | 0 | 0 | specifies address translation technique. |
1.3.6.1.4.1.5.1.1.17.3.1.3 | accX25PktSize, sbeX25PktSize | 0 | 0 | specifies default data packet size for this port. |
1.3.6.1.4.1.5.1.1.17.3.1.4 | accX25PktWind, sbeX25PktWind | 0 | 0 | specifies default packet window size for this port. |
1.3.6.1.4.1.5.1.1.17.3.1.5 | accX25SvcNumber, sbeX25SvcNumber | 0 | 0 | specifies maximum number of switched virtual circuits to be used on this port. |
1.3.6.1.4.1.5.1.1.17.3.1.6 | accX25SvcBase, sbeX25SvcBase | 0 | 0 | specifies lowest Logical Channel Identifier to be used for switched virtual circuits. |
1.3.6.1.4.1.5.1.1.17.3.1.7 | accX25ExtendClr, sbeX25ExtendClr | 0 | 0 | specifies whether extended format for call clearing packets (as defined by X.25-1984) is permitted |
1.3.6.1.4.1.5.1.1.17.3.1.8 | accX25ExtendSeq, sbeX25ExtendSeq | 0 | 0 | Use of extended sequence numbers |
1.3.6.1.4.1.5.1.1.17.3.1.9 | accX25IdleMin, sbeX25IdleMin | 0 | 0 | minimum idle time for closing circuits; a circuit will not be cleared until it has been idle (no data has been sent or received) … |
1.3.6.1.4.1.5.1.1.17.3.1.10 | accX25IdleMax, sbeX25IdleMax | 0 | 0 | maximum idle time for closing circuits; a circuit will be cleared when its idle time exceeds this value. |
1.3.6.1.4.1.5.1.1.17.3.1.11 | accX25IdleScale, sbeX25IdleScale | 0 | 0 | scale factor for idle timeout: a circuit will be cleared when it has been idle for accX25IdleMin plus accX25IdleScale times the n… |
1.3.6.1.4.1.5.1.1.17.3.1.12 | accX25SvcMax | 0 | 0 | Maximum number of virtual circuits which can be opened to a single destination. |
1.3.6.1.4.1.5.1.1.17.3.1.13 | accX25SvcLimit | 0 | 0 | Maximum number of switched virtual circuits that IP can use. The value must not exceed the total number of logical channels avai… |
1.3.6.1.4.1.5.1.1.17.3.1.14 | accX25OpenThresh | 0 | 0 | Threshold (number of IP datagrams queued per circuit) at which an additional virtual circuit will be opened. |
1.3.6.1.4.1.5.1.1.17.3.1.15 | accX25SvcMin | 0 | 0 | The minimum number of virtual circuits which IP will leave available for first circuits to other destinations |
1.3.6.1.4.1.5.1.1.17.3.1.16 | accX25SvcDelay | 0 | 0 | Delay (seconds) between opening of successive virtual circuits to same destination. |
1.3.6.1.4.1.5.1.1.17.3.1.17 | accX25InitBackoff | 0 | 0 | Initial backoff time (seconds) to delay before next attempt to open an additional virtual circuit to the same destination when an… |
1.3.6.1.4.1.5.1.1.17.3.1.19 | accX25OurAddress | 0 | 0 | Our X25 address (put in outbound packets) |
1.3.6.1.4.1.5.1.1.17.3.1.20 | accX25PvcBase | 0 | 0 | Lowest LCID to be used for PVCs. |
1.3.6.1.4.1.5.1.1.17.3.1.21 | accX25PvcNumber | 0 | 0 | Maximum number of PVCs. |
1.3.6.1.4.1.5.1.1.17.3.1.22 | accX25Tx0Timer | 0 | 0 | Value for T10 (DCE) or T20 (DTE) timer. |
1.3.6.1.4.1.5.1.1.17.3.1.23 | accX25Tx1Timer | 0 | 0 | Value for T11 (DCE) or T21 (DTE) timer. |
1.3.6.1.4.1.5.1.1.17.3.1.24 | accX25Tx2Timer | 0 | 0 | Value for T12 (DCE) or T22 (DTE) timer. |
1.3.6.1.4.1.5.1.1.17.3.1.25 | accX25Tx3Timer | 0 | 0 | Value for T13 (DCE) or T23 (DTE) timer. |
1.3.6.1.4.1.5.1.1.17.3.1.26 | accX25PortEventSeverityLevel | 0 | 0 | The base severity level which events are recorded. |