Reference record for OID 1.3.6.1.4.1.52.4.1.1.10.5.1.1



parent
1.3.6.1.4.1.52.4.1.1.10.5.1 (upsOutputTable)
node code
1
node name
upsOutputEntry
dot oid
1.3.6.1.4.1.52.4.1.1.10.5.1.1
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cabletron(52) mibs(4) ctron(1) ctPhysical(1) ctUPS(10) upsOutput(5) upsOutputTable(1) upsOutputEntry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cabletron(52) mibs(4) ctron(1) hubMgmt(1) ctUPS(10) upsOutput(5) upsOutputTable(1) upsOutputEntry(1)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) IMPORTS(52) mibs(4) ctron(1) ctPhysical(1) ctUPS(10) upsOutput(5) upsOutputTable(1) upsOutputEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) IMPORTS(52) mibs(4) ctron(1) hubMgmt(1) ctUPS(10) upsOutput(5) upsOutputTable(1) upsOutputEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) cabletron(52) mibs(4) ctron(1) ctPhysical(1) ctUPS(10) upsOutput(5) upsOutputTable(1) upsOutputEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) cabletron(52) mibs(4) ctron(1) hubMgmt(1) ctUPS(10) upsOutput(5) upsOutputTable(1) upsOutputEntry(1)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) IMPORTS(52) mibs(4) ctron(1) ctPhysical(1) ctUPS(10) upsOutput(5) upsOutputTable(1) upsOutputEntry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) IMPORTS(52) mibs(4) ctron(1) hubMgmt(1) ctUPS(10) upsOutput(5) upsOutputTable(1) upsOutputEntry(1)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/cabletron/mibs/ctron/ctPhysical/ctUPS/upsOutput/upsOutputTable/upsOutputEntry
  • /iso/identified-organization/dod/internet/private/enterprise/cabletron/mibs/ctron/hubMgmt/ctUPS/upsOutput/upsOutputTable/upsOutputEntry
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/IMPORTS/mibs/ctron/ctPhysical/ctUPS/upsOutput/upsOutputTable/upsOutputEntry
  • /iso/org/dod/internet/private/enterprise/IMPORTS/mibs/ctron/hubMgmt/ctUPS/upsOutput/upsOutputTable/upsOutputEntry
  • /iso/org/dod/internet/private/enterprises/cabletron/mibs/ctron/ctPhysical/ctUPS/upsOutput/upsOutputTable/upsOutputEntry
  • /iso/org/dod/internet/private/enterprises/cabletron/mibs/ctron/hubMgmt/ctUPS/upsOutput/upsOutputTable/upsOutputEntry
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/IMPORTS/mibs/ctron/ctPhysical/ctUPS/upsOutput/upsOutputTable/upsOutputEntry
  • /iso/iso-identified-organization/dod/internet/private/enterprises/IMPORTS/mibs/ctron/hubMgmt/ctUPS/upsOutput/upsOutputTable/upsOutputEntry
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/52/4/1/1/10/5/1/1

    Description by mibdepot

    An entry containing objects for a particular UPS.

    Parsed from file ctups2-mib.mib.txt
    Company: None
    Module: UPS2-MIB

    Description by circitor

    An entry containing objects for a particular UPS.

    Parsed from file UPS2-MIB.mib
    Module: UPS2-MIB

    Information by mibdepot

    upsOutputEntry OBJECT-TYPE SYNTAX UpsOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing objects for a particular UPS." INDEX { upsIndex } ::= { upsOutputTable 1 }

    Information by oid_info

    Vendor: Enterasys Networks Inc.
    Module: UPS2-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    upsOutputEntry OBJECT-TYPE SYNTAX UpsOutputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing objects for a particular UPS." INDEX { upsIndex } ::= { upsOutputTable 1 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.52)

    McTague Charles N.

    Children (3)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.52.4.1.1.10.5.1.1.1 upsOutputVoltage 0 0 The measured UPS output voltage. The value of this
    object is the actual voltage * 10 (that is, to determine
    the actual voltage, …
    1.3.6.1.4.1.52.4.1.1.10.5.1.1.2 upsOutputUtilityVoltage 0 0 The UPS's current on-battery output voltage setting
    (valid for 220/230/240 Vac version UPSs only). For other
    version UPSs, readi…
    1.3.6.1.4.1.52.4.1.1.10.5.1.1.3 upsOutputPower 0 0 The UPS's output load represented as a percentage of full
    rated load in Watts. The value of this object is the actual
    percentage…