Reference record for OID 1.3.6.1.4.1.52.4.1.1.10.5.1.1.1
- parent
- 1.3.6.1.4.1.52.4.1.1.10.5.1.1 (upsOutputEntry)
- node code
- 1
- node name
- upsOutputVoltage
- dot oid
- 1.3.6.1.4.1.52.4.1.1.10.5.1.1.1
- type
- OBJECT-TYPE
- asn1 oid
-
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cabletron(52) mibs(4) ctron(1) ctPhysical(1) ctUPS(10) upsOutput(5) upsOutputTable(1) upsOutputEntry(1) upsOutputVoltage(1)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cabletron(52) mibs(4) ctron(1) hubMgmt(1) ctUPS(10) upsOutput(5) upsOutputTable(1) upsOutputEntry(1) upsOutputVoltage(1)}
- ...skipped...
- {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) IMPORTS(52) mibs(4) ctron(1) ctPhysical(1) ctUPS(10) upsOutput(5) upsOutputTable(1) upsOutputEntry(1) upsOutputVoltage(1)}
- {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) IMPORTS(52) mibs(4) ctron(1) hubMgmt(1) ctUPS(10) upsOutput(5) upsOutputTable(1) upsOutputEntry(1) upsOutputVoltage(1)}
- {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) cabletron(52) mibs(4) ctron(1) ctPhysical(1) ctUPS(10) upsOutput(5) upsOutputTable(1) upsOutputEntry(1) upsOutputVoltage(1)}
- {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) cabletron(52) mibs(4) ctron(1) hubMgmt(1) ctUPS(10) upsOutput(5) upsOutputTable(1) upsOutputEntry(1) upsOutputVoltage(1)}
- ...skipped...
- {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) IMPORTS(52) mibs(4) ctron(1) ctPhysical(1) ctUPS(10) upsOutput(5) upsOutputTable(1) upsOutputEntry(1) upsOutputVoltage(1)}
- {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) IMPORTS(52) mibs(4) ctron(1) hubMgmt(1) ctUPS(10) upsOutput(5) upsOutputTable(1) upsOutputEntry(1) upsOutputVoltage(1)}
- iri oid
-
- /iso/identified-organization/dod/internet/private/enterprise/cabletron/mibs/ctron/ctPhysical/ctUPS/upsOutput/upsOutputTable/upsOutputEntry/upsOutputVoltage
- /iso/identified-organization/dod/internet/private/enterprise/cabletron/mibs/ctron/hubMgmt/ctUPS/upsOutput/upsOutputTable/upsOutputEntry/upsOutputVoltage
- ...skipped...
- /iso/org/dod/internet/private/enterprise/IMPORTS/mibs/ctron/ctPhysical/ctUPS/upsOutput/upsOutputTable/upsOutputEntry/upsOutputVoltage
- /iso/org/dod/internet/private/enterprise/IMPORTS/mibs/ctron/hubMgmt/ctUPS/upsOutput/upsOutputTable/upsOutputEntry/upsOutputVoltage
- /iso/org/dod/internet/private/enterprises/cabletron/mibs/ctron/ctPhysical/ctUPS/upsOutput/upsOutputTable/upsOutputEntry/upsOutputVoltage
- /iso/org/dod/internet/private/enterprises/cabletron/mibs/ctron/hubMgmt/ctUPS/upsOutput/upsOutputTable/upsOutputEntry/upsOutputVoltage
- ...skipped...
- /iso/iso-identified-organization/dod/internet/private/enterprises/IMPORTS/mibs/ctron/ctPhysical/ctUPS/upsOutput/upsOutputTable/upsOutputEntry/upsOutputVoltage
- /iso/iso-identified-organization/dod/internet/private/enterprises/IMPORTS/mibs/ctron/hubMgmt/ctUPS/upsOutput/upsOutputTable/upsOutputEntry/upsOutputVoltage
- iri by oid_info
- /ISO/Identified-Organization/6/1/4/1/52/4/1/1/10/5/1/1/1
Description by mibdepot
The measured UPS output voltage. The value of this
object is the actual voltage * 10 (that is, to determine
the actual voltage, divide the value of this object by
10).
Parsed from file ctups2-mib.mib.txt
Company: None
Module: UPS2-MIB
Description by circitor
The measured UPS output voltage. The value of this
object is the actual voltage * 10 (that is, to determine
the actual voltage, divide the value of this object by
10).
Parsed from file UPS2-MIB.mib
Module: UPS2-MIB
Information by mibdepot
upsOutputVoltage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The measured UPS output voltage. The value of this
object is the actual voltage * 10 (that is, to determine
the actual voltage, divide the value of this object by
10)."
::= { upsOutputEntry 1 }
Information by oid_info
Vendor: Enterasys Networks Inc.
Module: UPS2-MIB
[Automatically extracted from oidview.com]
Information by circitor
upsOutputVoltage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The measured UPS output voltage. The value of this
object is the actual voltage * 10 (that is, to determine
the actual voltage, divide the value of this object by
10)."
::= { upsOutputEntry 1 }
First Registration Authority (recovered by parent 1.3.6.1.4.1.52)
McTague Charles N.
Brothers (2)
OID | Name | Sub children | Sub Nodes Total | Description |
1.3.6.1.4.1.52.4.1.1.10.5.1.1.2 |
upsOutputUtilityVoltage |
0 |
0 |
The UPS's current on-battery output voltage setting (valid for 220/230/240 Vac version UPSs only). For other version UPSs, readiā¦ |
1.3.6.1.4.1.52.4.1.1.10.5.1.1.3 |
upsOutputPower |
0 |
0 |
The UPS's output load represented as a percentage of full rated load in Watts. The value of this object is the actual percentageā¦ |