Reference record for OID 1.3.6.1.4.1.529.23.66.1.1


parent
1.3.6.1.4.1.529.23.66.1 (mibcltmCmdTable)
node code
1
node name
mibcltmCmdEntry
dot oid
1.3.6.1.4.1.529.23.66.1.1
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) ascend(529) configuration(23) mibcltmCmd(66) mibcltmCmdTable(1) mibcltmCmdEntry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) ascend(529) configuration(23) mibcltmCmd(66) mibcltmCmdTable(1) mibcltmCmdEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) ascend(529) configuration(23) mibcltmCmd(66) mibcltmCmdTable(1) mibcltmCmdEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) ascend(529) configuration(23) mibcltmCmd(66) mibcltmCmdTable(1) mibcltmCmdEntry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) ascend(529) configuration(23) mibcltmCmd(66) mibcltmCmdTable(1) mibcltmCmdEntry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) ascend(529) configuration(23) mibcltmCmd(66) mibcltmCmdTable(1) mibcltmCmdEntry(1)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/ascend/configuration/mibcltmCmd/mibcltmCmdTable/mibcltmCmdEntry
  • /iso/identified-organization/dod/internet/private/enterprises/ascend/configuration/mibcltmCmd/mibcltmCmdTable/mibcltmCmdEntry
  • /iso/org/dod/internet/private/enterprise/ascend/configuration/mibcltmCmd/mibcltmCmdTable/mibcltmCmdEntry
  • /iso/org/dod/internet/private/enterprises/ascend/configuration/mibcltmCmd/mibcltmCmdTable/mibcltmCmdEntry
  • /iso/iso-identified-organization/dod/internet/private/enterprise/ascend/configuration/mibcltmCmd/mibcltmCmdTable/mibcltmCmdEntry
  • /iso/iso-identified-organization/dod/internet/private/enterprises/ascend/configuration/mibcltmCmd/mibcltmCmdTable/mibcltmCmdEntry
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/529/23/66/1/1

    Description by circitor

    A mibcltmCmd entry containing objects that
    maps to the parameters of mibcltmCmd profile.

    Parsed from file ASCEND-MIBCLTM-MIB.mib
    Module: ASCEND-MIBCLTM-MIB

    Information by oid_info

    Vendor: Ascend Communications Inc.
    Module: ASCEND-MIBCLTM-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    mibcltmCmdEntry OBJECT-TYPE SYNTAX MibcltmCmdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A mibcltmCmd entry containing objects that maps to the parameters of mibcltmCmd profile." INDEX { cltmCmd-Index-o } ::= { mibcltmCmdTable 1 }

    Children (47)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.529.23.66.1.1.1 cltmCmd-Index-o 0 0 None
    1.3.6.1.4.1.529.23.66.1.1.2 cltmCmd-CltmSlot 0 0 Identify the CLTM slot within the system.
    1.3.6.1.4.1.529.23.66.1.1.3 cltmCmd-TestTimeStamp 0 0 Value of the sysUpTime when the last test command was issued. This parameter is cleared when any of the test parameters are cha…
    1.3.6.1.4.1.529.23.66.1.1.4 cltmCmd-TestSequence 0 0 Sequence of the last issued test command.
    1.3.6.1.4.1.529.23.66.1.1.5 cltmCmd-TestOperation 0 0 The current operation that is active on the CLT Module. Defaultls to 'none'. Set to 'none' to stop the test procedure.
    1.3.6.1.4.1.529.23.66.1.1.6 cltmCmd-DmmType 0 0 DMM Measurement Type.
    1.3.6.1.4.1.529.23.66.1.1.7 cltmCmd-DmmLead 0 0 DMM Measurement Leads.
    1.3.6.1.4.1.529.23.66.1.1.8 cltmCmd-BackgroundNoiseFilter 0 0 Line Filter Type for Background Noise Test.
    1.3.6.1.4.1.529.23.66.1.1.9 cltmCmd-BackgroundNoiseTermination 0 0 Line Termination Type for Background Noise Test.
    1.3.6.1.4.1.529.23.66.1.1.10 cltmCmd-LoopResistanceUnit 0 0 Measurement System for Loop Resistance Test.
    1.3.6.1.4.1.529.23.66.1.1.11 cltmCmd-LoopResistanceTemp 0 0 Line Temperature for Loop Resistance Test. Assigned in degree celsius/fahrenheit.
    1.3.6.1.4.1.529.23.66.1.1.12 cltmCmd-ImpulseNoiseStartThresh 0 0 Threshold for Impulse Noise Test. The Range is 50-100 dBrm.
    1.3.6.1.4.1.529.23.66.1.1.13 cltmCmd-ImpulseNoiseStartDelta 0 0 Delta Value for Impulse Noise Test. The delta range is 2-6 dB
    1.3.6.1.4.1.529.23.66.1.1.14 cltmCmd-ImpulseNoiseStartMaxCount 0 0 Max Count for Impulse Noise Test. The range of the value is 1-1999.
    1.3.6.1.4.1.529.23.66.1.1.15 cltmCmd-ImpulseNoiseStartDeadTime 0 0 Dead Time Value for Impulse Noise Start Test. The value is assigned in 0.1 ms increments.
    1.3.6.1.4.1.529.23.66.1.1.16 cltmCmd-ImpulseNoiseStartTimer 0 0 Timer values for Impulse Noise Start Test. The value is assigned in 1 minute increment.
    1.3.6.1.4.1.529.23.66.1.1.17 cltmCmd-CalibrationType 0 0 Calibration Type
    1.3.6.1.4.1.529.23.66.1.1.18 cltmCmd-ToneSendFreq 0 0 Tone Send Frequency in KHz.
    1.3.6.1.4.1.529.23.66.1.1.19 cltmCmd-ToneSendLevel 0 0 Tone Send Level in dBm.
    1.3.6.1.4.1.529.23.66.1.1.20 cltmCmd-ToneSendPeriod 0 0 Amount of time a tone is sent (1-20 Minutes).
    1.3.6.1.4.1.529.23.66.1.1.21 cltmCmd-TdrUnit 0 0 Measurement System for TDR Test.
    1.3.6.1.4.1.529.23.66.1.1.22 cltmCmd-TdrGauge 0 0 TDR gauge. This is either 22/24/26 AWG for English system or 6/5/4 (0.1mm) for the metric system.
    1.3.6.1.4.1.529.23.66.1.1.23 cltmCmd-TdrVp 0 0 TDR VP as percentage of the speed of light.
    1.3.6.1.4.1.529.23.66.1.1.24 cltmCmd-TdrAvg 0 0 Number of trials to get the avarage.
    1.3.6.1.4.1.529.23.66.1.1.25 cltmCmd-TdrGetType 0 0 TDR Test Range Measurement Type. If set to automatic cltmCmdTdrStartLen and cltmCmdTdrMeasureLen do not need to be set.
    1.3.6.1.4.1.529.23.66.1.1.26 cltmCmd-TdrStartDistance 0 0 TDR Start Length for MANUAL mode, the value is given in feet (15..20000) for the English system and cm (460..609750) for the me…
    1.3.6.1.4.1.529.23.66.1.1.27 cltmCmd-TdrMeasurementLength 0 0 TDR Measurement Length for MANUAL mode, the value is given in feet (300..20000) for the English system and cm (9150..609750) fo…
    1.3.6.1.4.1.529.23.66.1.1.28 cltmCmd-DmmdcdPeriod 0 0 Amount of time measurement is made (0,1-5 100ms;0=MAX).
    1.3.6.1.4.1.529.23.66.1.1.29 cltmCmd-DmmdcdVoltage 0 0 Test voltage to be used (-230 to 230 Volts).
    1.3.6.1.4.1.529.23.66.1.1.30 cltmCmd-DmmdcdImpedance 0 0 Output Impedance to be used (10 to 1000 Kohms).
    1.3.6.1.4.1.529.23.66.1.1.31 cltmCmd-DmmcapPeriod 0 0 Amount of time measurement is made (0,1-5 100ms;0=MAX).
    1.3.6.1.4.1.529.23.66.1.1.32 cltmCmd-DmmallType 0 0 DMM Measurement Type.
    1.3.6.1.4.1.529.23.66.1.1.33 cltmCmd-DmmallPeriod 0 0 Amount of time measurement is made (0,1-5 100ms;0=MAX).
    1.3.6.1.4.1.529.23.66.1.1.34 cltmCmd-DmmallInputImp 0 0 Input Impedance (100, 1000 Kohm).
    1.3.6.1.4.1.529.23.66.1.1.35 cltmCmd-CtoneType 0 0 Control tone, type of DSL service (ADSL, GLITE).
    1.3.6.1.4.1.529.23.66.1.1.36 cltmCmd-CtoneTone 0 0 Control tone, type of Tone (QUIET, RESTORE).
    1.3.6.1.4.1.529.23.66.1.1.37 cltmCmd-TtoneLead 0 0 trace tone, Measurement Leads.
    1.3.6.1.4.1.529.23.66.1.1.38 cltmCmd-TtoneLevel 0 0 trace tone, Tone Send Level in dBm.
    1.3.6.1.4.1.529.23.66.1.1.39 cltmCmd-TtonePeriod 0 0 trace tone, Amount of time a tone is sent (1-20 Minutes).
    1.3.6.1.4.1.529.23.66.1.1.40 cltmCmd-BtapStartLength 0 0 Measurement start length (15 - 20000 ft. or 5 - 6097 meter).
    1.3.6.1.4.1.529.23.66.1.1.41 cltmCmd-BtapMeasureLength 0 0 Measurement length (100 - 20000 ft. or 32 - 6097 meter).
    1.3.6.1.4.1.529.23.66.1.1.42 cltmCmd-Action-o 0 0 None
    1.3.6.1.4.1.529.23.66.1.1.43 cltmCmd-FcllocUnit 0 0 Measurement System for FCLLOC Test.
    1.3.6.1.4.1.529.23.66.1.1.44 cltmCmd-FcllocGauge 0 0 FCLLOC gauge. This is either 22/24/26 AWG for English system or 6/5/4 (0.1mm) for the metric system.
    1.3.6.1.4.1.529.23.66.1.1.45 cltmCmd-ShortlocUnit 0 0 Measurement System for SHORTLOC Test.
    1.3.6.1.4.1.529.23.66.1.1.46 cltmCmd-ShortlocGauge 0 0 SHORTLOC gauge. This is either 22/24/26 AWG for English system or 6/5/4 (0.1mm) for the metric system.
    1.3.6.1.4.1.529.23.66.1.1.47 cltmCmd-ShortlocType 0 0 SHORTLOC test type.