Tone Send Frequency in KHz.
Parsed from file ASCEND-MIBCLTM-MIB.mib
Module: ASCEND-MIBCLTM-MIB
Vendor: Ascend Communications Inc.
Module: ASCEND-MIBCLTM-MIB
[Automatically extracted from oidview.com]
cltmCmd-ToneSendFreq OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Tone Send Frequency in KHz." ::= { mibcltmCmdEntry 18 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.529.23.66.1.1.1 | cltmCmd-Index-o | 0 | 0 | None |
1.3.6.1.4.1.529.23.66.1.1.2 | cltmCmd-CltmSlot | 0 | 0 | Identify the CLTM slot within the system. |
1.3.6.1.4.1.529.23.66.1.1.3 | cltmCmd-TestTimeStamp | 0 | 0 | Value of the sysUpTime when the last test command was issued. This parameter is cleared when any of the test parameters are cha… |
1.3.6.1.4.1.529.23.66.1.1.4 | cltmCmd-TestSequence | 0 | 0 | Sequence of the last issued test command. |
1.3.6.1.4.1.529.23.66.1.1.5 | cltmCmd-TestOperation | 0 | 0 | The current operation that is active on the CLT Module. Defaultls to 'none'. Set to 'none' to stop the test procedure. |
1.3.6.1.4.1.529.23.66.1.1.6 | cltmCmd-DmmType | 0 | 0 | DMM Measurement Type. |
1.3.6.1.4.1.529.23.66.1.1.7 | cltmCmd-DmmLead | 0 | 0 | DMM Measurement Leads. |
1.3.6.1.4.1.529.23.66.1.1.8 | cltmCmd-BackgroundNoiseFilter | 0 | 0 | Line Filter Type for Background Noise Test. |
1.3.6.1.4.1.529.23.66.1.1.9 | cltmCmd-BackgroundNoiseTermination | 0 | 0 | Line Termination Type for Background Noise Test. |
1.3.6.1.4.1.529.23.66.1.1.10 | cltmCmd-LoopResistanceUnit | 0 | 0 | Measurement System for Loop Resistance Test. |
1.3.6.1.4.1.529.23.66.1.1.11 | cltmCmd-LoopResistanceTemp | 0 | 0 | Line Temperature for Loop Resistance Test. Assigned in degree celsius/fahrenheit. |
1.3.6.1.4.1.529.23.66.1.1.12 | cltmCmd-ImpulseNoiseStartThresh | 0 | 0 | Threshold for Impulse Noise Test. The Range is 50-100 dBrm. |
1.3.6.1.4.1.529.23.66.1.1.13 | cltmCmd-ImpulseNoiseStartDelta | 0 | 0 | Delta Value for Impulse Noise Test. The delta range is 2-6 dB |
1.3.6.1.4.1.529.23.66.1.1.14 | cltmCmd-ImpulseNoiseStartMaxCount | 0 | 0 | Max Count for Impulse Noise Test. The range of the value is 1-1999. |
1.3.6.1.4.1.529.23.66.1.1.15 | cltmCmd-ImpulseNoiseStartDeadTime | 0 | 0 | Dead Time Value for Impulse Noise Start Test. The value is assigned in 0.1 ms increments. |
1.3.6.1.4.1.529.23.66.1.1.16 | cltmCmd-ImpulseNoiseStartTimer | 0 | 0 | Timer values for Impulse Noise Start Test. The value is assigned in 1 minute increment. |
1.3.6.1.4.1.529.23.66.1.1.17 | cltmCmd-CalibrationType | 0 | 0 | Calibration Type |
1.3.6.1.4.1.529.23.66.1.1.19 | cltmCmd-ToneSendLevel | 0 | 0 | Tone Send Level in dBm. |
1.3.6.1.4.1.529.23.66.1.1.20 | cltmCmd-ToneSendPeriod | 0 | 0 | Amount of time a tone is sent (1-20 Minutes). |
1.3.6.1.4.1.529.23.66.1.1.21 | cltmCmd-TdrUnit | 0 | 0 | Measurement System for TDR Test. |
1.3.6.1.4.1.529.23.66.1.1.22 | cltmCmd-TdrGauge | 0 | 0 | TDR gauge. This is either 22/24/26 AWG for English system or 6/5/4 (0.1mm) for the metric system. |
1.3.6.1.4.1.529.23.66.1.1.23 | cltmCmd-TdrVp | 0 | 0 | TDR VP as percentage of the speed of light. |
1.3.6.1.4.1.529.23.66.1.1.24 | cltmCmd-TdrAvg | 0 | 0 | Number of trials to get the avarage. |
1.3.6.1.4.1.529.23.66.1.1.25 | cltmCmd-TdrGetType | 0 | 0 | TDR Test Range Measurement Type. If set to automatic cltmCmdTdrStartLen and cltmCmdTdrMeasureLen do not need to be set. |
1.3.6.1.4.1.529.23.66.1.1.26 | cltmCmd-TdrStartDistance | 0 | 0 | TDR Start Length for MANUAL mode, the value is given in feet (15..20000) for the English system and cm (460..609750) for the me… |
1.3.6.1.4.1.529.23.66.1.1.27 | cltmCmd-TdrMeasurementLength | 0 | 0 | TDR Measurement Length for MANUAL mode, the value is given in feet (300..20000) for the English system and cm (9150..609750) fo… |
1.3.6.1.4.1.529.23.66.1.1.28 | cltmCmd-DmmdcdPeriod | 0 | 0 | Amount of time measurement is made (0,1-5 100ms;0=MAX). |
1.3.6.1.4.1.529.23.66.1.1.29 | cltmCmd-DmmdcdVoltage | 0 | 0 | Test voltage to be used (-230 to 230 Volts). |
1.3.6.1.4.1.529.23.66.1.1.30 | cltmCmd-DmmdcdImpedance | 0 | 0 | Output Impedance to be used (10 to 1000 Kohms). |
1.3.6.1.4.1.529.23.66.1.1.31 | cltmCmd-DmmcapPeriod | 0 | 0 | Amount of time measurement is made (0,1-5 100ms;0=MAX). |
1.3.6.1.4.1.529.23.66.1.1.32 | cltmCmd-DmmallType | 0 | 0 | DMM Measurement Type. |
1.3.6.1.4.1.529.23.66.1.1.33 | cltmCmd-DmmallPeriod | 0 | 0 | Amount of time measurement is made (0,1-5 100ms;0=MAX). |
1.3.6.1.4.1.529.23.66.1.1.34 | cltmCmd-DmmallInputImp | 0 | 0 | Input Impedance (100, 1000 Kohm). |
1.3.6.1.4.1.529.23.66.1.1.35 | cltmCmd-CtoneType | 0 | 0 | Control tone, type of DSL service (ADSL, GLITE). |
1.3.6.1.4.1.529.23.66.1.1.36 | cltmCmd-CtoneTone | 0 | 0 | Control tone, type of Tone (QUIET, RESTORE). |
1.3.6.1.4.1.529.23.66.1.1.37 | cltmCmd-TtoneLead | 0 | 0 | trace tone, Measurement Leads. |
1.3.6.1.4.1.529.23.66.1.1.38 | cltmCmd-TtoneLevel | 0 | 0 | trace tone, Tone Send Level in dBm. |
1.3.6.1.4.1.529.23.66.1.1.39 | cltmCmd-TtonePeriod | 0 | 0 | trace tone, Amount of time a tone is sent (1-20 Minutes). |
1.3.6.1.4.1.529.23.66.1.1.40 | cltmCmd-BtapStartLength | 0 | 0 | Measurement start length (15 - 20000 ft. or 5 - 6097 meter). |
1.3.6.1.4.1.529.23.66.1.1.41 | cltmCmd-BtapMeasureLength | 0 | 0 | Measurement length (100 - 20000 ft. or 32 - 6097 meter). |
1.3.6.1.4.1.529.23.66.1.1.42 | cltmCmd-Action-o | 0 | 0 | None |
1.3.6.1.4.1.529.23.66.1.1.43 | cltmCmd-FcllocUnit | 0 | 0 | Measurement System for FCLLOC Test. |
1.3.6.1.4.1.529.23.66.1.1.44 | cltmCmd-FcllocGauge | 0 | 0 | FCLLOC gauge. This is either 22/24/26 AWG for English system or 6/5/4 (0.1mm) for the metric system. |
1.3.6.1.4.1.529.23.66.1.1.45 | cltmCmd-ShortlocUnit | 0 | 0 | Measurement System for SHORTLOC Test. |
1.3.6.1.4.1.529.23.66.1.1.46 | cltmCmd-ShortlocGauge | 0 | 0 | SHORTLOC gauge. This is either 22/24/26 AWG for English system or 6/5/4 (0.1mm) for the metric system. |
1.3.6.1.4.1.529.23.66.1.1.47 | cltmCmd-ShortlocType | 0 | 0 | SHORTLOC test type. |