This attribute indicates the cause of the current local end failure
experienced by the IMA group. The failure may have occurred
during a start-up procedure or during normal operation. Possible
values are:
noFailure: no local end failure.
noGoodLinksInStartup: no good links were available during IMA
start-up.
badGidInStartup: during start-up, different group identifiers (GIDs)
were received on the links.
badLidInStartup: during start-up, duplicate link identifiers (LIDs)
were received on the links.
unsupportedFrameLengthInStartup: during start-up, an
unsupported frame length was received.
timeoutInStartup: a time-out has occurred during start-up.
noGoodLinks: no good links are available in the IMA group.
remoteFailure: the far end is down.
unsupportedSymmetryInStartup: the symmetry proposed by the far
end is not supported on the near-end. This value will occur when
the IMA group is running the ATM Forum protocol and the far end
is proposing a group symmetry other than 'symmetric configuration
and operation'.
Parsed from file nortelPC-imaV1.mib.txt
Company: None
Module: Nortel-MsCarrier-MscPassport-ImaMIB
This attribute indicates the cause of the current local end failure
experienced by the IMA group. The failure may have occurred
during a start-up procedure or during normal operation. Possible
values are:
noFailure: no local end failure.
noGoodLinksInStartup: no good links were available during IMA
start-up.
badGidInStartup: during start-up, different group identifiers (GIDs)
were received on the links.
badLidInStartup: during start-up, duplicate link identifiers (LIDs)
were received on the links.
unsupportedFrameLengthInStartup: during start-up, an
unsupported frame length was received.
timeoutInStartup: a time-out has occurred during start-up.
noGoodLinks: no good links are available in the IMA group.
remoteFailure: the far end is down.
unsupportedSymmetryInStartup: the symmetry proposed by the far
end is not supported on the near-end. This value will occur when
the IMA group is running the ATM Forum protocol and the far end
is proposing a group symmetry other than 'symmetric configuration
and operation'.
Parsed from file Nortel-MsCarrier-MscPassport-ImaMIB.mib
Module: Nortel-MsCarrier-MscPassport-ImaMIB
Vendor: Northern Telecom, Ltd.
Module: Nortel-MsCarrier-MscPassport-ImaMIB
[Automatically extracted from oidview.com]
mscLpImaFailureCause OBJECT-TYPE SYNTAX INTEGER { noFailure(0), noGoodLinksInStartup(1), badGidInStartup(2), badLidInStartup(3), unsupportedFrameLengthInStartup(4), timeoutInStartup(5), noGoodLinks(6), remoteFailure(7), unsupportedSymmetryInStartup(8) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the cause of the current local end failure experienced by the IMA group. The failure may have occurred during a start-up procedure or during normal operation. Possible values are: noFailure: no local end failure. noGoodLinksInStartup: no good links were available during IMA start-up. badGidInStartup: during start-up, different group identifiers (GIDs) were received on the links. badLidInStartup: during start-up, duplicate link identifiers (LIDs) were received on the links. unsupportedFrameLengthInStartup: during start-up, an unsupported frame length was received. timeoutInStartup: a time-out has occurred during start-up. noGoodLinks: no good links are available in the IMA group. remoteFailure: the far end is down. unsupportedSymmetryInStartup: the symmetry proposed by the far end is not supported on the near-end. This value will occur when the IMA group is running the ATM Forum protocol and the far end is proposing a group symmetry other than 'symmetric configuration and operation'." ::= { mscLpImaOperEntry 1 }
mscLpImaFailureCause OBJECT-TYPE SYNTAX INTEGER { noFailure(0), noGoodLinksInStartup(1), badGidInStartup(2), badLidInStartup(3), unsupportedFrameLengthInStartup(4), timeoutInStartup(5), noGoodLinks(6), remoteFailure(7), unsupportedSymmetryInStartup(8) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates the cause of the current local end failure experienced by the IMA group. The failure may have occurred during a start-up procedure or during normal operation. Possible values are: noFailure: no local end failure. noGoodLinksInStartup: no good links were available during IMA start-up. badGidInStartup: during start-up, different group identifiers (GIDs) were received on the links. badLidInStartup: during start-up, duplicate link identifiers (LIDs) were received on the links. unsupportedFrameLengthInStartup: during start-up, an unsupported frame length was received. timeoutInStartup: a time-out has occurred during start-up. noGoodLinks: no good links are available in the IMA group. remoteFailure: the far end is down. unsupportedSymmetryInStartup: the symmetry proposed by the far end is not supported on the near-end. This value will occur when the IMA group is running the ATM Forum protocol and the far end is proposing a group symmetry other than 'symmetric configuration and operation'." ::= { mscLpImaOperEntry 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.562.36.2.1.12.22.11.1.2 | mscLpImaRemoteDefect | 0 | 0 | This attribute indicates the cause of the current far end defect experienced by the IMA group. For the ATM Forum IMA protocol, po… |
1.3.6.1.4.1.562.36.2.1.12.22.11.1.3 | mscLpImaRemoteLidsConfig | 0 | 0 | This attribute indicates all the links which have been configured in the remote IMA group. For example, if links 1, 3 and 5 have… |
1.3.6.1.4.1.562.36.2.1.12.22.11.1.4 | mscLpImaRemoteLidsActive | 0 | 0 | This attribute indicates all the links which are active in the remote IMA group. For example, if links 1 and 5 are active in the… |
1.3.6.1.4.1.562.36.2.1.12.22.11.1.5 | mscLpImaCellCapacity | 0 | 0 | This attribute indicates the total cell capacity (in cells per second) which is provided to the ATM layer. This cell capacity ta… |
1.3.6.1.4.1.562.36.2.1.12.22.11.1.6 | mscLpImaRemoteGid | 0 | 0 | This attribute indicates the IMA group identifier (GID) used by the remote IMA. A value of 0 will be displayed if the group is n… |
1.3.6.1.4.1.562.36.2.1.12.22.11.1.7 | mscLpImaClockingModeMismatch | 0 | 0 | This attribute indicates whether or not both ends of the IMA group are using the same transmit clocking mode (itc/ctc). Its valu… |