This attribute indicates whether or not both ends of the IMA group
are using the same transmit clocking mode (itc/ctc). Its value will be
yes if both ends are not using the same transmit clocking mode. A
clocking mode mismatch does not prevent an IMA group from
coming up and can be corrected by using the same clocking mode at
both ends.
This attribute will always have a value of no if the protocol for the
IMA group is proprietary.
Parsed from file nortelPC-imaV1.mib.txt
Company: None
Module: Nortel-MsCarrier-MscPassport-ImaMIB
This attribute indicates whether or not both ends of the IMA group
are using the same transmit clocking mode (itc/ctc). Its value will be
yes if both ends are not using the same transmit clocking mode. A
clocking mode mismatch does not prevent an IMA group from
coming up and can be corrected by using the same clocking mode at
both ends.
This attribute will always have a value of no if the protocol for the
IMA group is proprietary.
Parsed from file Nortel-MsCarrier-MscPassport-ImaMIB.mib
Module: Nortel-MsCarrier-MscPassport-ImaMIB
Vendor: Northern Telecom, Ltd.
Module: Nortel-MsCarrier-MscPassport-ImaMIB
[Automatically extracted from oidview.com]
mscLpImaClockingModeMismatch OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates whether or not both ends of the IMA group are using the same transmit clocking mode (itc/ctc). Its value will be yes if both ends are not using the same transmit clocking mode. A clocking mode mismatch does not prevent an IMA group from coming up and can be corrected by using the same clocking mode at both ends. This attribute will always have a value of no if the protocol for the IMA group is proprietary." ::= { mscLpImaOperEntry 7 }
mscLpImaClockingModeMismatch OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates whether or not both ends of the IMA group are using the same transmit clocking mode (itc/ctc). Its value will be yes if both ends are not using the same transmit clocking mode. A clocking mode mismatch does not prevent an IMA group from coming up and can be corrected by using the same clocking mode at both ends. This attribute will always have a value of no if the protocol for the IMA group is proprietary." ::= { mscLpImaOperEntry 7 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.562.36.2.1.12.22.11.1.1 | mscLpImaFailureCause | 0 | 0 | This attribute indicates the cause of the current local end failure experienced by the IMA group. The failure may have occurred d… |
1.3.6.1.4.1.562.36.2.1.12.22.11.1.2 | mscLpImaRemoteDefect | 0 | 0 | This attribute indicates the cause of the current far end defect experienced by the IMA group. For the ATM Forum IMA protocol, po… |
1.3.6.1.4.1.562.36.2.1.12.22.11.1.3 | mscLpImaRemoteLidsConfig | 0 | 0 | This attribute indicates all the links which have been configured in the remote IMA group. For example, if links 1, 3 and 5 have… |
1.3.6.1.4.1.562.36.2.1.12.22.11.1.4 | mscLpImaRemoteLidsActive | 0 | 0 | This attribute indicates all the links which are active in the remote IMA group. For example, if links 1 and 5 are active in the… |
1.3.6.1.4.1.562.36.2.1.12.22.11.1.5 | mscLpImaCellCapacity | 0 | 0 | This attribute indicates the total cell capacity (in cells per second) which is provided to the ATM layer. This cell capacity ta… |
1.3.6.1.4.1.562.36.2.1.12.22.11.1.6 | mscLpImaRemoteGid | 0 | 0 | This attribute indicates the IMA group identifier (GID) used by the remote IMA. A value of 0 will be displayed if the group is n… |