Reference record for OID 1.3.6.1.4.1.562.36.2.1.12.5.6.16.1.3



parent
1.3.6.1.4.1.562.36.2.1.12.5.6.16.1 (mscLpDS3DS1OperEntry)
node code
3
node name
mscLpDS3DS1RxRaiAlarm
dot oid
1.3.6.1.4.1.562.36.2.1.12.5.6.16.1.3
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nortel(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpDS3(5) mscLpDS3DS1(6) mscLpDS3DS1OperTable(16) mscLpDS3DS1OperEntry(1) mscLpDS3DS1RxRaiAlarm(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) northernTelecom(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpDS3(5) mscLpDS3DS1(6) mscLpDS3DS1OperTable(16) mscLpDS3DS1OperEntry(1) mscLpDS3DS1RxRaiAlarm(3)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) northernTelecom(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpDS3(5) mscLpDS3DS1(6) mscLpDS3DS1OperTable(16) mscLpDS3DS1OperEntry(1) mscLpDS3DS1RxRaiAlarm(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) nt(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpDS3(5) mscLpDS3DS1(6) mscLpDS3DS1OperTable(16) mscLpDS3DS1OperEntry(1) mscLpDS3DS1RxRaiAlarm(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) nortel(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpDS3(5) mscLpDS3DS1(6) mscLpDS3DS1OperTable(16) mscLpDS3DS1OperEntry(1) mscLpDS3DS1RxRaiAlarm(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) northernTelecom(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpDS3(5) mscLpDS3DS1(6) mscLpDS3DS1OperTable(16) mscLpDS3DS1OperEntry(1) mscLpDS3DS1RxRaiAlarm(3)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) northernTelecom(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpDS3(5) mscLpDS3DS1(6) mscLpDS3DS1OperTable(16) mscLpDS3DS1OperEntry(1) mscLpDS3DS1RxRaiAlarm(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nt(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpDS3(5) mscLpDS3DS1(6) mscLpDS3DS1OperTable(16) mscLpDS3DS1OperEntry(1) mscLpDS3DS1RxRaiAlarm(3)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/nortel/msCarrier/mscPassport/mscComponents/mscLp/mscLpDS3/mscLpDS3DS1/mscLpDS3DS1OperTable/mscLpDS3DS1OperEntry/mscLpDS3DS1RxRaiAlarm
  • /iso/identified-organization/dod/internet/private/enterprise/northernTelecom/msCarrier/mscPassport/mscComponents/mscLp/mscLpDS3/mscLpDS3DS1/mscLpDS3DS1OperTable/mscLpDS3DS1OperEntry/mscLpDS3DS1RxRaiAlarm
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/northernTelecom/msCarrier/mscPassport/mscComponents/mscLp/mscLpDS3/mscLpDS3DS1/mscLpDS3DS1OperTable/mscLpDS3DS1OperEntry/mscLpDS3DS1RxRaiAlarm
  • /iso/org/dod/internet/private/enterprise/nt/msCarrier/mscPassport/mscComponents/mscLp/mscLpDS3/mscLpDS3DS1/mscLpDS3DS1OperTable/mscLpDS3DS1OperEntry/mscLpDS3DS1RxRaiAlarm
  • /iso/org/dod/internet/private/enterprises/nortel/msCarrier/mscPassport/mscComponents/mscLp/mscLpDS3/mscLpDS3DS1/mscLpDS3DS1OperTable/mscLpDS3DS1OperEntry/mscLpDS3DS1RxRaiAlarm
  • /iso/org/dod/internet/private/enterprises/northernTelecom/msCarrier/mscPassport/mscComponents/mscLp/mscLpDS3/mscLpDS3DS1/mscLpDS3DS1OperTable/mscLpDS3DS1OperEntry/mscLpDS3DS1RxRaiAlarm
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/northernTelecom/msCarrier/mscPassport/mscComponents/mscLp/mscLpDS3/mscLpDS3DS1/mscLpDS3DS1OperTable/mscLpDS3DS1OperEntry/mscLpDS3DS1RxRaiAlarm
  • /iso/iso-identified-organization/dod/internet/private/enterprises/nt/msCarrier/mscPassport/mscComponents/mscLp/mscLpDS3/mscLpDS3DS1/mscLpDS3DS1OperTable/mscLpDS3DS1OperEntry/mscLpDS3DS1RxRaiAlarm
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/562/36/2/1/12/5/6/16/1/3

    Description by mibdepot

    This attribute indicates whether an RAI (Remote Alarm Indication)
    alarm state has been entered. An RAI alarm state is entered when
    the RAI defect indicator has been observed and accumulated for 3.5
    seconds +/- 0.5 seconds. If the RAI defects are intermittently
    occurring, the RAI defect accumulator is decremented at a rate of 1/
    10 of the incrementing rate (alarm integration ratio of 1/10), with all
    measurements based on a 200 ms polling cycle.
    The RAI alarm state is cleared when the RAI defect indicator has
    been absent for 10 seconds +/- 0.5 seconds. The RAI alarm is
    usually an indication that the far end facility is unable to gain
    synchronization.

    Parsed from file nortelPC-logicalProcessorV1.mib.txt
    Company: None
    Module: Nortel-MsCarrier-MscPassport-LogicalProcessorMIB

    Description by circitor

    This attribute indicates whether an RAI (Remote Alarm Indication)
    alarm state has been entered. An RAI alarm state is entered when
    the RAI defect indicator has been observed and accumulated for 3.5
    seconds +/- 0.5 seconds. If the RAI defects are intermittently
    occurring, the RAI defect accumulator is decremented at a rate of 1/
    10 of the incrementing rate (alarm integration ratio of 1/10), with all
    measurements based on a 200 ms polling cycle.
    The RAI alarm state is cleared when the RAI defect indicator has
    been absent for 10 seconds +/- 0.5 seconds. The RAI alarm is
    usually an indication that the far end facility is unable to gain
    synchronization.

    Parsed from file Nortel-MsCarrier-MscPassport-LogicalProcessorMIB.mib
    Module: Nortel-MsCarrier-MscPassport-LogicalProcessorMIB

    Information by oid_info

    Vendor: Northern Telecom, Ltd.
    Module: Nortel-MsCarrier-MscPassport-LogicalProcessorMIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    mscLpDS3DS1RxRaiAlarm OBJECT-TYPE SYNTAX INTEGER { on(0), off(1) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates whether an RAI (Remote Alarm Indication) alarm state has been entered. An RAI alarm state is entered when the RAI defect indicator has been observed and accumulated for 3.5 seconds +/- 0.5 seconds. If the RAI defects are intermittently occurring, the RAI defect accumulator is decremented at a rate of 1/ 10 of the incrementing rate (alarm integration ratio of 1/10), with all measurements based on a 200 ms polling cycle. The RAI alarm state is cleared when the RAI defect indicator has been absent for 10 seconds +/- 0.5 seconds. The RAI alarm is usually an indication that the far end facility is unable to gain synchronization." DEFVAL { off } ::= { mscLpDS3DS1OperEntry 3 }

    Information by circitor

    mscLpDS3DS1RxRaiAlarm OBJECT-TYPE SYNTAX INTEGER { on(0), off(1) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute indicates whether an RAI (Remote Alarm Indication) alarm state has been entered. An RAI alarm state is entered when the RAI defect indicator has been observed and accumulated for 3.5 seconds +/- 0.5 seconds. If the RAI defects are intermittently occurring, the RAI defect accumulator is decremented at a rate of 1/ 10 of the incrementing rate (alarm integration ratio of 1/10), with all measurements based on a 200 ms polling cycle. The RAI alarm state is cleared when the RAI defect indicator has been absent for 10 seconds +/- 0.5 seconds. The RAI alarm is usually an indication that the far end facility is unable to gain synchronization." DEFVAL { off } ::= { mscLpDS3DS1OperEntry 3 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.562)

    Sharon Chisholm

    Current Registration Authority (recovered by parent 1.3.6.1.4.1.562)

    Mike Bobbitt

    Brothers (4)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.562.36.2.1.12.5.6.16.1.1 mscLpDS3DS1RxAisAlarm 0 0 This attribute indicates whether an AIS (Alarm Indication Signal)
    alarm state has been entered. The AIS Alarm state is entered w…
    1.3.6.1.4.1.562.36.2.1.12.5.6.16.1.2 mscLpDS3DS1LofAlarm 0 0 This attribute indicates whether a LOF (Loss of Frame) alarm state
    has been entered. The LOF alarm state is entered when LOF def…
    1.3.6.1.4.1.562.36.2.1.12.5.6.16.1.4 mscLpDS3DS1TxAisAlarm 0 0 This attribute indicates whether an AIS (Alarm Indication Signal)
    alarm is being transmitted on the line. An AIS alarm is transm…
    1.3.6.1.4.1.562.36.2.1.12.5.6.16.1.5 mscLpDS3DS1TxRaiAlarm 0 0 This attribute indicates whether a RAI signal is being sent on the
    outgoing line. The RAI signal is transmitted when the tributa…