Reference record for OID 1.3.6.1.4.1.562.36.2.1.12.6.16.1.4



parent
1.3.6.1.4.1.562.36.2.1.12.6.16.1 (mscLpE3OperEntry)
node code
4
node name
mscLpE3RxRaiAlarm
dot oid
1.3.6.1.4.1.562.36.2.1.12.6.16.1.4
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nortel(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpE3(6) mscLpE3OperTable(16) mscLpE3OperEntry(1) mscLpE3RxRaiAlarm(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) northernTelecom(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpE3(6) mscLpE3OperTable(16) mscLpE3OperEntry(1) mscLpE3RxRaiAlarm(4)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) northernTelecom(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpE3(6) mscLpE3OperTable(16) mscLpE3OperEntry(1) mscLpE3RxRaiAlarm(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) nt(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpE3(6) mscLpE3OperTable(16) mscLpE3OperEntry(1) mscLpE3RxRaiAlarm(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) nortel(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpE3(6) mscLpE3OperTable(16) mscLpE3OperEntry(1) mscLpE3RxRaiAlarm(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) northernTelecom(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpE3(6) mscLpE3OperTable(16) mscLpE3OperEntry(1) mscLpE3RxRaiAlarm(4)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) northernTelecom(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpE3(6) mscLpE3OperTable(16) mscLpE3OperEntry(1) mscLpE3RxRaiAlarm(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nt(562) msCarrier(36) mscPassport(2) mscComponents(1) mscLp(12) mscLpE3(6) mscLpE3OperTable(16) mscLpE3OperEntry(1) mscLpE3RxRaiAlarm(4)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/nortel/msCarrier/mscPassport/mscComponents/mscLp/mscLpE3/mscLpE3OperTable/mscLpE3OperEntry/mscLpE3RxRaiAlarm
  • /iso/identified-organization/dod/internet/private/enterprise/northernTelecom/msCarrier/mscPassport/mscComponents/mscLp/mscLpE3/mscLpE3OperTable/mscLpE3OperEntry/mscLpE3RxRaiAlarm
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/northernTelecom/msCarrier/mscPassport/mscComponents/mscLp/mscLpE3/mscLpE3OperTable/mscLpE3OperEntry/mscLpE3RxRaiAlarm
  • /iso/org/dod/internet/private/enterprise/nt/msCarrier/mscPassport/mscComponents/mscLp/mscLpE3/mscLpE3OperTable/mscLpE3OperEntry/mscLpE3RxRaiAlarm
  • /iso/org/dod/internet/private/enterprises/nortel/msCarrier/mscPassport/mscComponents/mscLp/mscLpE3/mscLpE3OperTable/mscLpE3OperEntry/mscLpE3RxRaiAlarm
  • /iso/org/dod/internet/private/enterprises/northernTelecom/msCarrier/mscPassport/mscComponents/mscLp/mscLpE3/mscLpE3OperTable/mscLpE3OperEntry/mscLpE3RxRaiAlarm
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/northernTelecom/msCarrier/mscPassport/mscComponents/mscLp/mscLpE3/mscLpE3OperTable/mscLpE3OperEntry/mscLpE3RxRaiAlarm
  • /iso/iso-identified-organization/dod/internet/private/enterprises/nt/msCarrier/mscPassport/mscComponents/mscLp/mscLpE3/mscLpE3OperTable/mscLpE3OperEntry/mscLpE3RxRaiAlarm
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/562/36/2/1/12/6/16/1/4

    Description by mibdepot

    This attribute displays whether a Remote Alarm Indication (RAI)
    alarm state has been entered. A RAI alarm state is entered when far-
    end SEF/AIS defects (or Far-End Receive Failure (FERF) defects in
    G.832 E3 Framing mode) have been observed and accumulated for
    a period of 2.5 seconds +/- 0.5 seconds on the E3 incoming line. If
    the RAI defects are intermittently occurring, the RAI defect
    accumulator is decremented at a rate of 1/10 of the incrementing
    rate (alarm integration ratio of 1/10), with all measurements based
    on a 200 ms polling cycle.
    The E3 component goes into an operational state of disabled until
    the RAI alarm condition is cleared. The condition is cleared when
    the far-end defect indicator has not been detected for 10 seconds +/-
    0.5 seconds. The declaration of a RAI Alarm is usually a signal that
    the far end facility is unable to gain synchronization.
    The rxRaiAlarm attribute is always set to off when the component
    has been locked and left offline.

    Parsed from file nortelPC-logicalProcessorV1.mib.txt
    Company: None
    Module: Nortel-MsCarrier-MscPassport-LogicalProcessorMIB

    Description by circitor

    This attribute displays whether a Remote Alarm Indication (RAI)
    alarm state has been entered. A RAI alarm state is entered when far-
    end SEF/AIS defects (or Far-End Receive Failure (FERF) defects in
    G.832 E3 Framing mode) have been observed and accumulated for
    a period of 2.5 seconds +/- 0.5 seconds on the E3 incoming line. If
    the RAI defects are intermittently occurring, the RAI defect
    accumulator is decremented at a rate of 1/10 of the incrementing
    rate (alarm integration ratio of 1/10), with all measurements based
    on a 200 ms polling cycle.
    The E3 component goes into an operational state of disabled until
    the RAI alarm condition is cleared. The condition is cleared when
    the far-end defect indicator has not been detected for 10 seconds +/-
    0.5 seconds. The declaration of a RAI Alarm is usually a signal that
    the far end facility is unable to gain synchronization.
    The rxRaiAlarm attribute is always set to off when the component
    has been locked and left offline.

    Parsed from file Nortel-MsCarrier-MscPassport-LogicalProcessorMIB.mib
    Module: Nortel-MsCarrier-MscPassport-LogicalProcessorMIB

    Information by oid_info

    Vendor: Northern Telecom, Ltd.
    Module: Nortel-MsCarrier-MscPassport-LogicalProcessorMIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    mscLpE3RxRaiAlarm OBJECT-TYPE SYNTAX INTEGER { on(0), off(1) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute displays whether a Remote Alarm Indication (RAI) alarm state has been entered. A RAI alarm state is entered when far- end SEF/AIS defects (or Far-End Receive Failure (FERF) defects in G.832 E3 Framing mode) have been observed and accumulated for a period of 2.5 seconds +/- 0.5 seconds on the E3 incoming line. If the RAI defects are intermittently occurring, the RAI defect accumulator is decremented at a rate of 1/10 of the incrementing rate (alarm integration ratio of 1/10), with all measurements based on a 200 ms polling cycle. The E3 component goes into an operational state of disabled until the RAI alarm condition is cleared. The condition is cleared when the far-end defect indicator has not been detected for 10 seconds +/- 0.5 seconds. The declaration of a RAI Alarm is usually a signal that the far end facility is unable to gain synchronization. The rxRaiAlarm attribute is always set to off when the component has been locked and left offline." DEFVAL { off } ::= { mscLpE3OperEntry 4 }

    Information by circitor

    mscLpE3RxRaiAlarm OBJECT-TYPE SYNTAX INTEGER { on(0), off(1) } ACCESS read-only STATUS mandatory DESCRIPTION "This attribute displays whether a Remote Alarm Indication (RAI) alarm state has been entered. A RAI alarm state is entered when far- end SEF/AIS defects (or Far-End Receive Failure (FERF) defects in G.832 E3 Framing mode) have been observed and accumulated for a period of 2.5 seconds +/- 0.5 seconds on the E3 incoming line. If the RAI defects are intermittently occurring, the RAI defect accumulator is decremented at a rate of 1/10 of the incrementing rate (alarm integration ratio of 1/10), with all measurements based on a 200 ms polling cycle. The E3 component goes into an operational state of disabled until the RAI alarm condition is cleared. The condition is cleared when the far-end defect indicator has not been detected for 10 seconds +/- 0.5 seconds. The declaration of a RAI Alarm is usually a signal that the far end facility is unable to gain synchronization. The rxRaiAlarm attribute is always set to off when the component has been locked and left offline." DEFVAL { off } ::= { mscLpE3OperEntry 4 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.562)

    Sharon Chisholm

    Current Registration Authority (recovered by parent 1.3.6.1.4.1.562)

    Mike Bobbitt

    Brothers (5)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.562.36.2.1.12.6.16.1.1 mscLpE3LosAlarm 0 0 This attribute displays whether a Loss Of Signal (LOS) alarm state
    has been entered. An LOS alarm state is entered when LOS defe…
    1.3.6.1.4.1.562.36.2.1.12.6.16.1.2 mscLpE3LofAlarm 0 0 This attribute displays whether a Loss Of Frame (LOF) alarm state
    has been entered. An LOF alarm state is entered when Severely
    E…
    1.3.6.1.4.1.562.36.2.1.12.6.16.1.3 mscLpE3RxAisAlarm 0 0 This attribute displays whether an Alarm Indication Signal (AIS)
    alarm when state has been entered. An AIS alarm state is entere…
    1.3.6.1.4.1.562.36.2.1.12.6.16.1.5 mscLpE3TxAis 0 0 This attribute displays whether an AIS alarm is being transmitted on
    the E3 line. AIS is transmitted on the outgoing line when t…
    1.3.6.1.4.1.562.36.2.1.12.6.16.1.6 mscLpE3TxRai 0 0 This attribute displays whether the far-end SEF/AIS defect indicator
    is transmitted over the outgoing line when the E3 component…